NOTES ON WIRING <br />QS CONTROL LINK <br />THE QS CONTROL LINK HAS A FREE WIRING TOPOLOGY (DAISY CHAIN, T-TAP, ETC). THE SYSTEM WIRING <br />ILLUSTRATED BY THIS DRAWING HAS BEEN LAID OUT TO ENSURE APPROPRIATE POWER TO EACH DEVICE. IF FOR <br />ANY REASON THE SYSTEM IS TO BE WIRED DIFFERENTLY THAN WHAT IS SHOWN, PLEASE CONFIRM ALL DEVICE <br />POWER REQUIREMENTS ARE MET (PLEASE REFER TO “QS LINK POWER REQUIREMENTS” FOR INDIVIDUAL DEVICE <br />POWER REQUIREMENTS). <br />FOR QS CONTROL WIRE LENGTHS TOTALING LESS THAN 500 FT (153 M), USE LUTRON CABLE GRX-CBL-346S (4 <br />CONDUCTOR NON-PLENUM), OR GRX-PCBL-346S (4 CONDUCTOR PLENUM). OTHERWISE USE 2 #18 AWG (1.0 SQ MM) + <br />2 #22 AWG (0.5 SQ MM) TWISTED AND SHIELDED OR EQUIVALENT (BELDEN #9461). FOR QS CONTROL WIRE LENGTHS <br />TOTALING UP TO 2,000 FT, USE GRX-CBL-46L (4 CONDUCTOR NON-PLENUM) OR GRX-PCBL-46L (4 CONDUCTOR <br />PLENUM). TOTAL QS CONTROL WIRE LENGTH MUST NOT EXCEED 2,000 FT (600 M). <br />ECOSYSTEM BUS/LOOP* <br />THIS IS A TOPOLOGY-FREE AND POLARITY-FREE WIRING (DAISY-CHAIN, T-TAP, HOME-RUN ETC.). KEEP ALL THE <br />BALLASTS/MODULES IN ONE ROOM ON THE SAME LOOP WHENEVER POSSIBLE. ECOSYSTEM LOOPS ARE SHOWN ON <br />THE LIGHTING PLANS. IF THERE IS A DISCREPANCY, AND IF ROOMS ARE WIRED ON A DIFFERENT LOOP THAN THE <br />ONE SHOWN, LUTRON NEEDS TO BE NOTIFIED AS THIS INFORMATION IS IMPORTANT FOR PROGRAMMING THE <br />SYSTEM. <br />USE LUTRON CABLE C-CBL-216-GR1 (2 #16 CONDUCTOR NON-PLENUM) OR C-PCBL-216-CL-1 (2 #16 CONDUCTOR <br />PLENUM RATED). OTHERWISE USE 2 #16 AWG (1.5 SQ MM) BY OTHERS. <br />LOOP LENGTH IS LIMITED BY THE WIRE GAUGE USED FOR E1 AND E2 AS FOLLOWS: <br />WIRE GAUGE MAX LOOP LENGTH <br />#18 AWG (1.0 SQ MM) <br />#16 AWG (1.5 SQ MM) <br />#14 AWG (2.5 SQ MM) <br />#12 AWG (4 SQ MM) <br />550 FT (167M) <br />900 FT (274M) <br />1,400 FT (426 M) <br />2,200 FT (670M) <br />NOTES FOR LED APPLICATIONS <br />FOR ANY FORWARD/REVERSE PHASE, 3-WIRE, 0-10 V AND SWITCHING LED DRIVERS, PLEASE VERIFY THE NUMBER <br />OF DRIVERS SUPPORTED ON EACH DEVICE. FOR MORE INFORMATION, PLEASE VISIT LUTRON’S LED CENTER OF <br />EXCELLENCE (WWW.LUTRON.COM/LEDS). <br />QS LINK POWER REQUIREMENTS <br />DEVICE PDUS <br />QS DEVICES THAT SUPPLY PDU <br />DIN RAIL POWER SUPPLY +75 <br />MYROOM DIN RAIL POWER SUPPLY +30 <br />QS PLUG-IN POWER SUPPLY, QS J-BOX POWER SUPPLY +8 <br />ENERGI SAVR NODE WITH ECOSYSTEM, ENERGI SAVR NODE WITH <br />DALI, ENERGI SAVR NODE WITH T-SERIES TUNABLE-WHITE +30 <br />ENERGI SAVR NODE FOR 0–10 V, ENERGI SAVR NODE WITH <br />SOFTSWITCH, ENERGI SAVR NODE FOR 0–10 V (DIN RAIL), ENERGI <br />SAVR NODE WITH SOFTSWITCH (DIN RAIL) <br />+14 <br />ENERGI SAVR NODE PHASE ADAPTIVE (DIN RAIL), 1 A MYROOM DIN <br />RAIL POWER MODULE SWITCHING, 1 A MYROOM DIN RAIL POWER <br />MODULE PHASE ADAPTIVE <br />+4 <br />ENERGI SAVR NODE WITH DALI (DIN RAIL), ENERGI SAVR NODE WITH <br />ECOSYSTEM (DIN RAIL)+3 <br />QS MOTOR GROUP CONTROLLER (DIN RAIL), HOMEWORKS QS DIN <br />RAIL POWER MODULES 0 <br />GRAFIK EYE QS (ALL MODELS EXCEPT GRAFIK EYE QS DALI WITH <br />KNX), QS TIMECLOCK +3 <br />QP2 QUANTUM LIGHTING HUB LINK A : 0 <br />LINKS B,C,D : +33 EACH <br />QP3 QUANTUM LIGHTING HUB LINKS A,B : +33 EACH <br />QS DEVICES THAT CONSUME PDU <br />QS WALLSTATION (SEETOUCH, ARCHITRAVE, SIGNATURE SERIES, QS <br />PICO, KEYSWITCH, SINGLE COLUMN PALLADIOM), QS SLIDER, GRAFIK <br />T SLIDER, QS INFRARED (IR) EYE, WALLBOX INPUT CLOSURE <br />INTERFACE <br />-1 <br />QS NETWORK INTERFACE, QS DMX INTERFACE, ENERGI SAVR NODE <br />PROGRAMMING INTERFACE, QS WALLSTATION (DOUBLE COLUMN <br />PALLADIOM) <br />-2 <br />QS SENSOR MODULE (QSM), NOT INCLUDING ATTACHED WIRED <br />SENSORS (SEE SECTION BELOW FOR MORE INFORMATION), QS <br />CONTACT CLOSURE INTERFACE, PALLADIOM ROOM THERMOSTAT <br />-3 <br />GUESTROOM CONTROL UNIT -8 <br />SENSORS & DEVICES THAT CONSUME PDUS WHEN WIRED TO A QSM <br />LUTRON DAYLIGHT SENSOR, LUTRON INFRARED (IR) RECEIVER, PICO <br />WIRED CONTROLLER -0.5 <br />ECOSYSTEM WALLSTATION -1 <br />LOS C SERIES OCCUPANCY SENSOR, HIGH BAY OCCUPANCY SENSOR -2 <br />ONSITE PRE-WIRE VISIT <br />(LSC-PREWIRE) <br />AN ONSITE VISIT WITH THE ELECTRICAL CONTRACTOR TO DISCUSS LOGISTICAL CONSTRUCTION CONSIDERATIONS INCLUDING THE <br />WIRING AND MOUNTING OF SYSTEM DEVICES, THE CONSTRUCTION SCHEDULE, AND LUTRON DOCUMENTATION. QUANTITY DICTATES <br />THE NUMBER OF VISITS PURCHASED. <br />SYSTEM & NETWORK <br />INTEGRATION <br />CONSULTATION <br />(LSC-INT-VISIT) <br />A CONSULTATIVE VISIT WITH THIRD PARTY INTEGRATORS TO CONFIRM THE SPECIFIED SEQUENCE OF OPERATION AND DISCUSS <br />INTEGRATION PROCEDURES NEEDED IN ORDER TO INTEGRATE WITH THE LUTRON EQUIPMENT. THIS MAY INCLUDE ANY OF THE <br />FOLLOWING THIRD PARTY SYSTEMS: BMS, BAS, IT, NON-LUTRON SHADES, BACNET, AV, OR ENERGY DASHBOARDS. <br />SENSOR LAYOUT & <br />TUNING <br />(LSC-SENS-LT) <br />LUTRON WILL TAKE RESPONSIBILITY FOR LUTRON-PROVIDED SENSOR PLACEMENT AND PERFORMANCE BY CREATING SENSOR <br />LAYOUTS AND COORDINATING SENSOR PLACEMENT BEFORE AND AFTER INSTALLATION. ONCE THE BUILDING IS OCCUPIED, LUTRON <br />WILL RETURN UP TO TWO TIMES TO PERFORM SENSOR FINE-TUNING. <br />AFTER HOURS STARTUP <br />(LSC-AH-SU) <br />STARTUP PROVIDED BETWEEN THE HOURS OF 5:00PM – 7:00AM, MONDAY - FRIDAY. THIS SCOPE OF WORK DOES NOT INCLUDE <br />HOLIDAY OR WEEKEND WORK. ADDITIONAL FEES MAY APPLY FOR WORK TO BE COMPLETED ON WEEKENDS (FRIDAY 5:00PM – <br />MONDAY 7:00AM). <br />ONSITE SCENE & LEVEL <br />TUNING <br />(LSC-AF-VISIT) <br />AN ONSITE VISIT WITH THE SPECIFIER OR CUSTOMER REPRESENTATIVE TO REVIEW THE DESIGN INTENT, FINE-TUNE THE SCENE <br />LEVEL PROGRAMMING, AND MAKE ADJUSTMENTS TO TIMECLOCKS. <br />ONSITE <br />PERFORMANCE-VERIFIC <br />ATION WALKTHROUGH <br />(LSC-WALK) <br />AN ONSITE WALKTHROUGH WITH FACILITY REPRESENTATIVES OR PROJECT COMMISSIONING AGENTS TO DEMONSTRATE THAT THE <br />SYSTEM FUNCTIONALITY MEETS THE DESIGN INTENT. THIS MAY INCLUDE ANY OF THE FOLLOWING ONSITE ACTIVITIES – <br />CONSULTATION/TRAINING DEMOS, FUNCTIONAL TESTING ASSISTANCE, OR INVENTORY OF LUTRON EQUIPMENT. <br />SYSTEM <br />PERFORMANCE-VERIFIC <br />ATION <br />DOCUMENTATION <br />(LSC-SPV-DOC) <br />COMPLETION OF DOCUMENTATION WHICH PROVIDES PERFORMANCE VERIFICATION CERTIFYING THE LUTRON EQUIPMENT HAS <br />BEEN THOROUGHLY TESTED. IT SUPPORTS THE DOCUMENTATION REQUIREMENTS OF MANY BUILDING STANDARDS. <br />TITLE 24 ACCEPTANCE <br />TEST VISIT <br />(LSC-SPV-DOC-T24) <br />ACCEPTANCE TESTING BY A LUTRON CERTIFIED LIGHTING CONTROL ACCEPTANCE TEST TECHNICIAN (CLCATT) TO FULFILL THE <br />REQUIRED TITLE 24 INTERIOR LIGHTING CONTROL TESTS. <br />CUSTOMER-SITE <br />SOLUTION TRAINING <br />(LSC-TRAINING-SP) <br />A VISIT TO TEACH SYSTEM USERS HOW TO OPERATE AND MAINTAIN THE LIGHTING CONTROL SYSTEM. <br />SYSTEM OPTIMIZATION <br />(LSC-SYSOPT-SP) <br />AN ONSITE CONSULTATIVE VISIT TO IDENTIFY AND IMPLEMENT LIGHTING CONTROL ADJUSTMENTS TO SAVE ADDITIONAL ENERGY <br />AND CREATE A MORE PRODUCTIVE WORK ENVIRONMENT. <br />ENHANCED SILVER <br />(LSC-E8S) <br />YEARS 1-2 - 100% REPLACEMENT PARTS AND 100% LUTRON DIAGNOSTIC LABOR COVERAGE WITH A FIRST-AVAILABLE RESPONSE <br />TIME; YEARS 3-5 - 50% PARTS ONLY COVERAGE; YEARS 6-8 - 25% PARTS ONLY COVERAGE. <br />ENHANCED GOLD <br />(LSC-E8G) <br />YEARS 1-2 - 100% REPLACEMENT PARTS AND 100% LUTRON DIAGNOSTIC LABOR COVERAGE WITH A 72-HOUR RESPONSE TIME AND <br />AN ANNUAL (1-DAY) SCHEDULED PREVENTIVE MAINTENANCE VISIT; YEARS 3-5 - 50% PARTS ONLY COVERAGE; YEARS 6-8 - 25% PARTS <br />ONLY COVERAGE. <br />ENHANCED PLATINUM <br />(LSC-E8P) <br />YEARS 1-2 - 100% REPLACEMENT PARTS AND 100% LUTRON DIAGNOSTIC LABOR COVERAGE WITH A 24-HOUR RESPONSE TIME AND <br />AN ANNUAL (1-DAY) SCHEDULED PREVENTIVE MAINTENANCE VISIT; YEARS 3-5 - 50% PARTS ONLY COVERAGE; YEARS 6-8 - 25% PARTS <br />ONLY COVERAGE. <br />SILVER TECHNOLOGY <br />SUPPORT PLAN <br />(LSC-SILV-IW) <br />AN ANNUAL SERVICE PLAN THAT COVERS 100% REPLACEMENT PARTS AND 100% LUTRON DIAGNOSTIC LABOR WITH A <br />FIRST-AVAILABLE ONSITE OR REMOTE RESPONSE TIME. <br />GOLD TECHNOLOGY <br />SUPPORT PLAN <br />(LSC-GOLD-IW) <br />AN ANNUAL SERVICE PLAN THAT COVERS 100% REPLACEMENT PARTS AND 100% LUTRON LABOR WITH A 72-HOUR ONSITE OR <br />REMOTE RESPONSE TIME. ALSO INCLUDES AN ANNUAL (1-DAY) SCHEDULED PREVENTIVE MAINTENANCE VISIT EACH YEAR. <br />PLATINUM <br />TECHNOLOGY <br />SUPPORT PLAN <br />(LSC-PLAT-IW) <br />AN ANNUAL SERVICE PLAN THAT COVERS 100% REPLACEMENT PARTS AND 100% LUTRON DIAGNOSTIC LABOR WITH A 24-HOUR <br />ONSITE OR REMOTE RESPONSE TIME. ALSO INCLUDES AN ANNUAL (1-DAY) SCHEDULED PREVENTIVE MAINTENANCE VISIT EACH <br />YEAR. <br />PREVENTIVE <br />MAINTENANCE VISIT(S) <br />(LSC-SCH-MAINT) <br />SCHEDULED MAINTENANCE VISIT TO PERFORM PREVENTIVE MAINTENANCE, MINOR PROGRAMMING, AND CONDUCT SYSTEM <br />TRAININGS. QUANTITY IS IN ADDITION TO ANY YEARLY VISITS SPECIFIED WITH AN ENHANCED WARRANTY OR TECHNOLOGY <br />SUPPORT PLAN. <br />LUTRON SERVICES <br />QTY <br />SERVICE TITLE <br />(MODEL NUMBER)SERVICE DESCRIPTION <br />THE QUANTITY OF SERVICES BELOW ARE TO BE INCLUDED AS PART OF THIS PROJECT'S SCOPE OF WORK AND SPECIFIED INTO THE WRITTEN SPEC <br />DOCUMENTS <br />PRE-STARTUP SERVICES <br />STARTUP SUPPORT SERVICES <br />(THESE SERVICES ARE ADDITIONAL TO YOUR SPECIFIED STARTUP BASED ON YOUR REQUIREMENTS) <br />POST-STARTUP SERVICES <br />MAINTENANCE & SUPPORT SERVICES <br />1 <br />COMMERCIAL SYSTEMS <br />2-YEAR LIMITED <br />WARRANTY <br />(LSC-B2) <br />A 2-YEAR SYSTEM WARRANTY PROVIDING 100% REPLACEMENT PARTS AND 100% LUTRON DIAGNOSTIC LABOR COVERAGE WITH A <br />FIRST-AVAILABLE RESPONSE TIME. <br />PLEASE GO TO WWW.LUTRON.COM/SERVICES FOR FURTHER INFORMATION. <br />FOR MORE INFORMATION CONTACT: <br />MANUEL ABELLO <br />(484) 221-5539 <br />mabello@lutron.com <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :5 1 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />E50-03 <br />LIGHTING CONTROL <br />RISER 2 <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018