Laserfiche WebLink
SAFETY RESTRAINT CLIP. <br />SUSPENDED CEILING <br />SYSTEM <br />AND BUILDING STRUCTURE AS REQUIRED <br />#12 SAFETY WIRE SECURED TO FIXTURE <br />BY FIXTURE WEIGHT <br />LIGHTING FIXTURE <br />LIGHTING FIXTURE. <br />MINIMUM OF (2) PER <br />TYPICAL MOTOR DISCONNECT SWITCH MOUNTING DETAIL NTSNTS NTS <br />NTS <br />TYPICAL DETAIL OF AIR DUCT SMOKE DETECTOR <br />A <br />4 X A <br />4 X A <br />2'-0" MIN.2'-0" MIN. <br />2'-0" MIN. <br />2'-0" MIN. <br />CONDUITS & PIPES SHALL <br />NOT BE SPACED CLOSER <br />THAN 4 TIMES THE <br />DIAMETER OF THE <br />CONDUITS ON CENTER <br />4 <br /> <br />X <br /> <br />A <br />INTERIOR FACE OF <br />CONCRETE WALL <br />A <br />2 3 <br />4 <br />9 <br />POWER WIRING (SEE NOTE 1) <br />INTERLOCK CONTROL WIRING 2#12-1/2"C <br />PROVIDE FUSED DISCONNECT SWITCH. <br />(NOT REQUIRED IF FUSED SWITCH IS <br />INTEGRAL TO THE VFD. COORDINATE <br />WITH THE SUPPLIER OF THE VFD'S) <br />VFD UNIT WIRING SCHEMATIC <br />VFD UNIT <br />N.T.S. <br />RECESSED LIGHT FIXTURE SUPPORT DETAIL N.T.S. <br />NEUTRAL BUS <br />FOR NORMAL <br />LIGHTING PANEL <br />NEUTRAL BUS <br />FOR LIFE SAFETY <br />PANEL <br />N <br />LIGHTING <br />PANEL <br />NORMAL <br />LIFE SAFETY <br />N <br />PANEL <br />LIGHTING <br />NORMAL LIGHTING <br />LOAD <br />LIFE SAFETY LOCAL LIGHTING <br />SWITCHING (TOGGLE SWITCH, <br />LIGHTING CONTROL RELAY OR DIMMER) <br />NORMAL LOCAL LIGHTING <br />SWITCHING (TOGGLE SWITCH, <br />LIGHTING CONTROL RELAY OR DIMMER) <br />LIFE SAFETY LIGHTING <br />LOAD UP TO 20A <br />VOLTAGE <br />GTD20 LIFE SAFETY LIGHTING <br />BYPASS DEVICE MANUFACTURED <br />BY "BODINE" OR EQUAL INSTALL <br />ABOVE ACCESSIBLE CEILING <br />SPACE <br />SENSING <br />GTD20 <br />LIGHTING CONTROL BY-PASS DETAIL N.T.S. <br />CADWELD CONNECTION <br />WITH PIGTAIL <br />(24" X 4" X 1/4") <br />COPPER BAR <br />INSULATORS <br />STAND-OFFS <br />12.7MM (1/2") <br />PRE-DRILLED <br />PRE-DRILLED <br />6.35MM (1/4") <br />PLATED, PRE-DRILLED <br />609.6MM X 101.6MM X 6.35MM <br />DIA TYP. <br />DIA TYP. <br />GROUNDING BAR DETAIL N.T.S. <br />TO FIRE ALARM <br />CONTROL PANEL <br />TO SUPPLY FAN <br />STARTER COIL <br />SUPPLY FAN <br />A.H.U.M <br />DS <br />FILTERDUCT <br />AIR SAMPLING <br />TUBES <br />DETAIL OF TYPICAL NAMEPLATE <br />1. REFER TO SPECIFICATIONS FOR ADDITIONAL NAMEPLATE REQUIREMENTS. <br />2. NAMEPLATE TO BE 1/16" WHITE PLASTIC WITH BLACK CENTER LAMINATION. <br />FACE TO BE WHITE, ENGRAVED LETTERS TO BE BLACK. <br />3. SECURE NAMEPLATE TO SURFACES WITH (2) FLAT HEAD BRASS SCREWS. <br />NOTES: <br />5/32" DIA. HOLE <br />1/4" LETTERS <br />(TYPICAL) <br />LIGHTING PANEL <br />277/480V., 3∅, 4W <br />FED FROM "D4BL" <br />3/4" <br />1 1/2' <br />"L41" <br />3 1/8" <br />2 3/4" <br />FINISHED FLOOR <br />FLANGE FASTENED TO FLOOR <br />USED <br />SUPPORT CONDUIT SHALL <br />BE FASTENED TO PULL <br />BOX WITH FLANGE AND <br />BOLTS. LOCKNUTS AND <br />BUSHINGS SHALL NOT BE <br />EQUIPMENT & HOUSE- <br />KEEPING PAD BY OTHERS <br />CONDUIT FROM MOTOR STARTER <br />FLEXIBLE CONDUIT CONNECTION <br />EMPTY RIGID CONDUIT OF SAME <br />SIZE AS THAT RUN FROM MOTOR <br />CONTAINING POWER CIRCUIT <br />MOTOR TERMINAL BOX <br />STARTER PROVIDED FOR <br />DISCONNECT SWITCH SUPPORT <br />WIRES 36" LONG MAXIMUM <br />DISCONNECT SWITCH <br />CONTAINING POWER AND <br />CONTROL CIRCUIT WIRES. <br />TYPICAL VARIABLE SPEED MOTOR/PUMP WIRING DIAGRAM <br />F <br />D <br />V <br />3 POLE 480VOLT DOUBLE <br />THROW SAFETY SWITCH <br />SECTION IN MOTOR DIST. <br />BOARD <br />VARIABLE FREQUENCY DRIVE FURNISHED AND <br />INSTALLED BY HVAC SUB-CONTRACTOR WIRED <br />BY ELECTRICAL SUB-CONTRACTOR <br />CONDUIT SPACING DETAIL NTS <br />PROVIDE FACTORY INSTALLED CONTROL CIRCUIT ELECTRICAL INTERLOCK ACCESSORY ON DISCONNECT <br />SWITCH. INTERLOCK WITH VFD SUCH THAT WHEN DISCONNECT SWITCH IS ABOUT TO BE OPENED THE VFD <br />IS COMMANDED TO STOP. <br />PROVIDE DISCONNECT SWITCH <br />REFER TO PLANS AND SCHEDULES FOR WIRE AND CONDUIT SIZE REQUIREMENTS FOR EACH MOTOR. <br />2. <br />NOTES: <br />1. <br />AT MOTOR, NOTE 2 <br />TO PANEL SEE PLANS <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :5 3 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />E90-01 <br />ELECTRICAL DETAILS <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018