T <br />R <br />VSD <br />H <br />CO <br />MM <br />CM <br />I/O <br />EM <br />IM <br />S <br />S <br />LOOP B <br />LOOP A <br />FIRE ALARM RISER NOTES: <br />PARTIAL FIRE ALARM RISER DIAGRAM <br />SCALE: N.T.S. <br /># <br />S <br />MANUAL PULL STATION MOUNTED 48" AFF. "WP" INDICATES WEATHERPROOF. "PC" <br />INDICATES PROTECTIVE COVER. <br />WALL MOUNTED COMBINATION AUDIO (SPEAKER)/VISUAL (STROBE) APPLIANCE. # <br />INDICATES CANDELA RATING. "HO" INDICATES HIGH-OUTPUT SPEAKER. <br />WALL MOUNTED VISUAL (STROBE) APPLIANCE. # INDICATES CANDELA RATING. <br />CEILING MOUNTED COMBINATION AUDIO (SPEAKER)/VISUAL (STROBE) APPLIANCE. <br /># INDICATES CANDELA RATING. "HO" INDICATES HIGH-OUTPUT SPEAKER. <br />CEILING MOUNTED AUDIO (SPEAKER). "HO" INDICATES HIGH-OUTPUT SPEAKER. <br />CEILING MOUNTED VISUAL (STROBE) APPLIANCE. # INDICATES CANDELA RATING. <br />REMOTE STATUS/ALARM INDICATOR <br />FIRE ALARM CONTROL PANEL. "M" INDICATES MAIN PANEL; "P" INDICATES PRIMARY <br />CONTROLS; "R" INDICATES REMOTE PANEL. <br />FIRE ALARM TERMINAL CABINET <br />FIREFIGHTER'S SMOKE CONTROL PANEL <br />AUXILIARY POWER SUPPLY <br />FIRE ALARM ANNUNCIATOR <br />OPERATOR'S WORKSTATION <br />GRAPHIC ANNUNCIATOR <br />END-OF-LINE RESISTOR <br />ROTATING BEACON <br />FIREFIGHTER'S TELEPHONE STATION <br />MAGNETIC DOOR HOLD OPEN DEVICE, FURNISHED AND INSTALLED BY DOOR HARDWARE <br />CONTRACTOR; WIRED BY THE ELECTRICAL CONTRACTOR. <br />AUXILIARY RELAY (INTERPOSING RELAY) <br />DUCT MOUNTED SMOKE DETECTOR. SMOKE DETECTOR PROVIDED AND WIRED BY <br />ELECTRICAL CONTRACTOR; INSTALLED BY MECHANICAL CONTRACTOR - REFER TO <br />MECHANICAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF ALL FIRE SMOKE <br />DAMPERS AND DUCT SMOKE DETECTORS. <br />REMOTE ALARM INDICATOR AND TEST SWITCH FOR DUCT SMOKE DETECTOR, WITH <br />NAMEPLATE LABELED ACCORDINGLY - (REFER TO MECHANICAL DRAWINGS FOR EXACT <br />LOCATION AND QUANTITY OF ALL FIRE SMOKE DAMPERS AND DUCT SMOKE DETECTORS.) <br />PHOTOELECTRIC SMOKE DETECTOR. "E" INDICATES FOR ELEVATOR RECALL; " T " <br />INDICATES WITH THERMAL BASE; "SB" INDICATES SOUNDER BASE; "I" INDICATES <br />IONIZATION, "ASD" INDICATES AIR SAMPLING DETECTOR; AND "PR" INDICATES FOR USE <br />WITH STAIR/ELEVATOR PRESSURIZATION. <br />MONITOR MODULE. "T" INDICATES TAMPER SWITCH, "F" INDICATES FLOW SWITCH, "P" <br />INDICATES PRESSURE SWITCH. (TAMPER AND FLOW SWITCH(ES) FURNISHED AND <br />INSTALLED BY THE GENERAL CONTRACTOR, WIRED BY THE ELECTRICAL CONTRACTOR.) - <br />(REFER TO FIRE PROTECTION DRAWINGS FOR EXACT LOCATION AND QUANTITY OF ALL <br />TAMPER, PRESSURE, AND FLOW SWITCHES.) <br />CONTROL MODULE <br />MULTI-POINT INPUT/OUTPUT MODULE. # INDICATES QUANTITY OF POINTS. <br />LINEAR BEAM SMOKE DETECTOR. "T" INDICATES TRANSMITTER. <br />LINEAR BEAM SMOKE DETECTOR. "R" INDICATES RECIEVER. <br />FIRE PROTECTION SPRINKLER BELL - FURNISHED AND INSTALLED BY PLUMBING <br />CONTRACTOR; WIRED BY ELECTRICAL CONTRACTOR. <br />FIRE ALARM PULLBOX <br />GAS SENSOR - [HONEYWELL E3 POINT OR APPROVED EQUAL] "CO" INDICATES CARBON <br />MONOXIDE SENSOR. <br />GAS MONITOR - [HONEYWELL E3SASCO OR APPROVED EQUAL] <br />FIRE ALARM MASTER BOX - LOCAL ENERGY <br />FIRE ALARM MASTER BOX - RADIO TRANSMITTER <br />UNINTERRUPTABLE POWER SUPPLY <br />VIDEO SMOKE DETECTOR (JOB SPECIFIC) <br />BI-DIRECTIONAL AMPLIFIER (BDA) <br />SPLITTER <br />RISER TERMINATION <br />OMNI-DIRECTIONAL ANTENNA <br />DIRECTIONAL ANTENNA <br />FIRE EXTINGUISHER MONITOR (JOB SPECIFIC) <br />FIXED TEMPERATURE HEAT DETECTOR. # INDICATES TEMPERATURE RATING. <br />4" SQUARE JUNCTION BOX MOUNTED ABOVE HUNG CEILING WITH FLEXIBLE CONNECTION. <br />"SD" INDICATES POWER CONNECTION TO SMOKE DAMPER; "FSD" INDICATES POWER <br />CONNECTION TO FIRE/SMOKE DAMPER; "DH" INDICATES POWER CONNECTION TO DOOR <br />HOLD OPEN DEVICE. <br />WALL MOUNTED AUDIO (SPEAKER) APPLIANCE. "HO" INDICATES HIGH-OUTPUT SPEAKER. <br />FIREFIGHTER'S SMOKE PURGE PANEL - (NON-LIFE SAFETY, POST EVENT PANEL) <br />TWO-WAY COMMUNICATION SYSTEM: MASTER STATION <br />(LOCATE IN THE FIRE COMMAND CENTER OR APPROVED LOCATION BY AHJ) <br />TWO-WAY COMMUNICATION SYSTEM: CONTROL STATION <br />(LOCATE AT DESIGNATED "AREA OF REFUGE/AREA OF RESCUE ASSISTANCE" IN EACH <br />ELEVATOR LOBBY) <br />REPOSITORY BOX - "KNOX BOX" ((2013 -PROVIDE KEY NOTE AND SHOW MONITOR MODULE <br />WITH TAMPER SWITCH AT REPOSITORY BOX) THIS IS IN CASE SOMEONE TRIES TO BREAK-IN, <br />REPOSITORY BOX IS SUPERVISED AND ALERTS "SOMEONE WHO CARES")) <br />SIGNAL BOOSTER REMOTE MONITORING PANEL (FOR BDA) <br />FAULT ISOLATION MODULE FOR USE ON SIGNALING LINE CIRCUIT WIRING <br />AFF ABOVE FINISHED FLOOR <br />AWG AMERICAN WIRE GAUGE <br />E EMERGENCY <br />ETD EXISTING TO DEMOLISH <br />ETR EXISTING TO REMAIN <br />ETRL EXISTING TO REMOVE AND RELOCATE <br />FT FEET <br />NEC NATIONAL ELECTRICAL CODE <br />NC NORMALLY CLOSED <br />NO NORMALLY OPEN <br />NTS NOT TO SCALE <br />PC PROTECTIVE COVER <br />PVC POLYVINYL CHLORIDE <br />TSP TWISTED/SHIELDED PAIR <br />WP WEATHERPROOF <br />XR <br />ERN EXISTING DEVICE/EQUIPMENT TO REMAIN. <br />RX NEW LOCATION OF RELOCATED EXISTING EQUIPMENT. <br />EXISTING EQUIPMENT SHALL BE DISCONNECTED, <br />REMOVED AND RELOCATED AS SHOWN. CUT BACK <br />AND/OR EXTEND EXISTING BRANCH CIRCUIT WIRING <br />AND CONDUIT AS REQUIRED SO AS TO PROVIDE A <br />COMPLETE OPERATIONAL INSTALLATION. <br />EXP EXPLOSION PROOF <br />SLC SIGNALING LINE CIRCUIT <br />ENL EXISTING NEW LOCATION. <br />PIV POST INDICATOR VALVE <br />TVSS TRANSIENT VOLTAGE SURGE <br />SUPPRESSION <br />ERR EXISTING TO REMOVE AND RELOCATE <br />LS LIFE SAFETY <br />NAC NOTIFICATION APPLIANCE CIRCUIT <br />F FACP <br />B <br />TC <br />FSCP <br />PS <br />FAA <br />WKST <br />F <br />GA <br />EOL <br />DH <br />R <br />GM <br />PB <br />M <br />UPS <br />BDA <br />J <br />FSPP <br />MS <br />CS <br />KB <br />RMP <br />CM <br />FIRE ALARM SYSTEM: <br /># <br /># <br /># <br /># <br />RADIO ENHANCEMENT SYSTEM (BDA): <br /># <br />FACP <br />TC <br />FSCP <br />GA <br />PS <br />FAA <br />WKST <br />UPS <br />FSCP <br />MS <br />CS <br />BDA <br />RMP <br />FIRE ALARM SYSTEM ABBREVIATIONS: <br />FIRE ALARM ANNOUNCIATOR PANEL LOCATED <br />IN THE LOBBY <br />EXISTING ANNUNCIATING DEVICES <br />EXISTING INITIATING DEVICES <br />NEW INITIATING DEVICES <br />NEW ANNUNCIATING DEVICES <br />EXACT LOCATIONS AND QUANTITIES OF DEVICES. THE EXISTING <br />THE FIRE ALARM RISER IS PARTIAL. REFER TO FLOOR PLANS <br />TAMPER AND FLOW SWITCHES LOCATED IN THE EXISTING <br />ALL FIRE ALARM JUNCTION BOXES SHALL BE PAINTED RED. <br />ALL FIRE ALARM WIRING SHALL BE INSTALLED IN A METAL <br />ALL CORE DRILLING AND FIRE STOPPING SHALL BE PROVIDED <br />APPROVAL BY OWNER. <br />THE EXISTING SYSTEM AND SHALL BE SUBJECT TO FINAL <br />ALL FIRE ALARM SYSTEM DEVICES SHALL BE COMPATIBLE WITH <br />ALARM MANUFACTURER FOR ALL NECESSARY HARDWARE, <br />THE ELECTRICAL CONTRACTOR SHALL CONTACT THE FIRE <br />STAIRWELL SHALL BE MAINTAINED. <br />RACEWAY. <br />BY THE G.C. <br />8) <br />5) <br />6) <br />4) <br />SOFTWARE AND ALL DEVICE REQUIREMENTS. <br />3) <br />2) <br />1) <br />THE ELECTRICAL CONTRACTOR SHALL CONTACT THE FA SYSTEM <br />MAINTENANCE CONTRACTOR FOR ALL NECESSARY WIRING REQUIREMENTS, <br />CONDUIT SIZES, DIAGRAMS AND SHOP DRAWINGS. <br />7)CONTRACTOR SHALL VERIFY THAT LAST DEVICE DOES NOT EXCEED <br />MANUFACTURER RECOMMENDED VOLTAGE DROP. PROVIDE NEW END OF LINE <br />RESISTOR. <br />ALL FIRE ALARM REPROGRAMMING TO ACCOMMODATE THE NEW WORK SHALL BE <br />PROVIDED BY EXISTING FA SYSTEM MAINTENANCE CONTRACTOR THE SYSTEM <br />SHALL BE TESTED IN ACCORDANCE WITH THE BASE BUILDING STANDARDS AFTER <br />COMPLETION OF NEW WORK TO ENSURE PROPER INTERCONNECTION WITH THE <br />EXISTING INFRASTRUCTURE. <br />9)CONTRACTOR SHALL PROVIDE SENSITIVITY TEST REPORTS FOR ALL NEW SMOKE <br />DETECTORS INSTALLED IN ACCORDANCE WITH NFPA 72 TESTING METHODS OF <br />SECTION 10.4. A TEST REPORT AND RECORD OF COMPLETION SHALL BE <br />SUBMITTED ON THE DAY OF FINAL INSPECTION. <br />CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FIRE ALARM SYSTEM <br />SPECIFICATION SHEETS AND ALL BATTERY CALCULATIONS FOR REVIEW PRIOR TO <br />ACQUIRING THE PERMIT. SHOP DRAWING SHALL BE SIGNED AND SEALED BY A <br />FLORIDA REGISTERED ENGINEER. <br />10) <br />11)AIR HANDLING UNIT SHALL SHUTDOWN UPON ACTIVATION OF FIRE ALARM <br />SYSTEM. <br />12) ALL DOORS WITH ELECTRIC LOCKS SHALL RELEASE UPON ACTIVATION OF <br />FIRE ALARM SYSTEM. <br />EXISTING FIRE ALARM CONTROL PANEL <br />EXISTING FIRE ALARM NAC PANEL <br />EXISITING FIRE ALARM ANNUCIATOR <br />VERIFY LOCATIONVERIFY LOCATION <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :5 4 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />FA00-00 <br />FIRE ALARM LEGEND, <br />NOTES & RISER <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018
The URL can be used to link to this page
Your browser does not support the video tag.