Laserfiche WebLink
(1) 1-1/4" CONDUIT TO <br />ACCESSIBLE CEILING <br />NOTES: <br />1. REFER TO AV DEVICE PRODUCT SHEETS FOR <br />PROPER BACKBOX REQUIREMENTS. <br />2. DETAIL IS SHOWN FOR DIAGRAMMATIC PURPOSE <br />TO SHOW INTENT. COORDINATE EXACT LOCATION <br />WITH ARCHITECTURAL ELEVATIONS. BACK BOX <br />AND CONDUIT FURNISHED AND INSTALLED BY <br />DIVISION 26. CABLING, TERMINATIONS, TESTING, <br />AND DEVICES BY OTHERS <br />2 GANG WITH 1 GANG MUD RING 2 GANG <br />(1) 1-1/4" CONDUIT TO <br />ACCESSIBLE CEILING <br />2 GANG BACK BOX <br />FOR AV DEVICE <br />NOTES: <br />1. REFER TO AV DEVICE PRODUCT SHEETS FOR <br />PROPER BACKBOX REQUIREMENTS. <br />2. DETAIL IS SHOWN FOR DIAGRAMMATIC PURPOSE <br />TO SHOW INTENT. COORDINATE EXACT LOCATION <br />WITH ARCHITECTURAL ELEVATIONS. BACK BOX <br />AND CONDUIT FURNISHED AND INSTALLED BY <br />DIVISION 26. CABLING, TERMINATIONS, TESTING, <br />AND DEVICES BY OTHERS <br />(1) 1-1/4" CONDUIT TO <br />ACCESSIBLE CEILING. <br />3 GANG BACK BOX <br />FOR AV DEVICE <br />NOTES: <br />1. REFER TO AV DEVICE PRODUCT SHEETS FOR <br />PROPER BACKBOX REQUIREMENTS. <br />2. DETAIL IS SHOWN FOR DIAGRAMMATIC PURPOSE <br />TO SHOW INTENT. COORDINATE EXACT LOCATION <br />WITH ARCHITECTURAL ELEVATIONS. BACK BOX <br />AND CONDUIT FURNISHED AND INSTALLED BY <br />DIVISION 26. CABLING, TERMINATIONS, TESTING, <br />AND DEVICES BY OTHERS <br />3 GANG <br />ADDITIONAL 1-1/4" CONDUIT TO <br />ACCESSIBLE CEILING IF NEEDED. <br />COORDINATE WITH AV <br />CONTRACTOR <br />(1) 1-1/4" CONDUIT TO <br />ACCESSIBLE CEILING <br />4 GANG BACK BOX <br />FOR AV DEVICE <br />NOTES: <br />1. REFER TO AV DEVICE PRODUCT SHEETS FOR <br />PROPER BACKBOX REQUIREMENTS. <br />2. DETAIL IS SHOWN FOR DIAGRAMMATIC PURPOSE <br />TO SHOW INTENT. COORDINATE EXACT LOCATION <br />WITH ARCHITECTURAL ELEVATIONS. BACK BOX <br />AND CONDUIT FURNISHED AND INSTALLED BY <br />DIVISION 26. CABLING, TERMINATIONS, TESTING, <br />AND DEVICES BY OTHERS <br />4-GANG <br />RECOMMENDED ELECTRICAL BOX: <br />RACO 560 3" X 2" BOX, 2 3/4" DEEP <br />GANGABLE OR EQUIVALENT. <br />RECOMMENDED ELECTRICAL <br />BOX COVER: RACO 864 SINGLE <br />DUPLEX <br />(1) 1-1/2" CONDUIT TO STUB UP <br />ABOVE ACCESSIBLE CEILING FOR <br />AV CABLING <br />NOTES: <br />1.FURNISHED AND INSTALLED BY DIVISION 26 CONTRACTOR. <br />2.DIVISION 26 CONTRACTOR SHALL FURNISH AND INSTALL (2) <br />DUPLEX OUTLETS AS SHOWN ON THIS DETAIL. <br />3.DIVISION 26 SHALL REFER TO ELECTRICAL SERIES DRAWINGS FOR <br />ADDITIONAL INFORMATION. <br />4.TV AND ASSOCIATED EQUIPMENT SHALL BE INSTALLED BY <br />OTHERS. <br />DATA OUTLET <br />(1) 1-1/4" CONDUIT TO WALL <br />MOUNTED AV DEVICE. SEE <br />DETAILS FOR ADDITIONAL <br />INFORMATION. <br />ELECTRICAL CONDUIT TO <br />ABOVE ACCESSIBLE CEILING. <br />REFER TO ELECTRICAL <br />DRAWINGS FOR ADDITIONAL <br />INFORMATION. <br />(1) 1-1/4" CONDUIT TO STUB UP <br />ABOVE ACCESSIBLE CEILING <br />FOR TELECOMMUNICATIONS <br />CABLING <br />DEDICATED 120V <br />ELECTRICAL <br />RECEPTACLE <br />DETAIL <br />POWER <br />RECEPTACL <br />E DATA OUTLET. SEE <br />COMMUNICATIONS DRAWINGS <br />FOR ADDITIONAL <br />INFORMATION. <br />SLAB <br />FINISHED CEILING -SEE RCP <br />FLOOR BOX DEVICE PROVIDED <br />BY ELECTRICAL CONTRACTOR <br />2" IN-SLAB CONDUIT FOR AV CABLING <br />1 1/4" SLAB CONDUIT FROM <br />TELECOMMUNICATIONS <br />OUTLET TO ABOVE <br />ACCESSIBLE CEILING WITHIN <br />THE ROOM <br />12"x12"x4" NEMA 1 <br />SC JUNCTION BOX <br />CO <br />O <br />R <br />D <br />. <br /> <br />M <br />O <br />U <br />N <br />T <br />I <br />N <br />G <br /> <br />HE <br />I <br />G <br />H <br />T <br /> <br />W <br />I <br />T <br />H <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />FURNITURE SYSTEM. REFER TO <br />ARCHITECTURAL DRAWINGS <br />AV40-03 <br />1 <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />ERIK S WALKER P.E: #63929 <br />JOHN MOUDLER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />RICARDO DURAN P.E: #64768 <br />GLEN R. SEILER P.E: #83347 <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 <br />t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELECTRICAL + PLUMBING <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />1 2 /4 /2 0 1 8 8 :0 7 :3 1 A M <br />C :\_R e v i t \T E C H - G A T E W A Y - v 2 0 1 8 _a v i l l a n u e v a C B Y X V .r v t <br />AV40-02 <br />AV INFRASTRUCTURE <br />DETAILS <br />JJP <br />AMV <br />810495.000 <br />JJP <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />N.T.S.1 AV BACKBOX DETAIL - 2 GANG WITH SINGLE GANG MUD RING <br />N.T.S2AV BACKBOX DETAIL - 2 GANG <br />N.T.S3AV BACKBOX DETAIL - 3 GANG <br />N.T.S4AV BACKBOX DETAIL - 4 GANG <br />N.T.S.5 AV DISPLAY WORKBOX <br />1/2" = 1'-0"6 AV FLOOR BOX PATHWAY DETAIL <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018