Laserfiche WebLink
S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />K <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />2 <br />a <br />2 <br />3 <br />3D <br />K <br />P <br />MC <br />J <br />1 <br />T2 <br />J OHD <br />J <br />PLUM <br />J <br />EWC <br />J <br />ATC <br />J <br />MP <br />TS <br />ERC <br />EH <br />TV <br />M <br />P <br />TL <br />ERH <br />M <br />2 <br />T <br />J <br />DRY <br />J <br />BLINDS <br />J FF <br />J <br />PROJ <br />J <br />TS <br />D1 <br />J <br />SIGN <br />NOTES: <br />LIGHTING FIXTURES <br />SWITCHES <br />RACEWAYS AND WIRING ONE LINE POWER DIAGRAM <br />POWER DISTRIBUTION EQUIPMENT <br />ABBREVIATIONS <br />MISCELLANEOUS <br />SYMBOL LIST <br />L43-1,3 <br />16 <br />F1 2 <br />a <br />F1 <br />2 <br />B <br />OCCUPANCY SENSOR NOTES: <br />MOUNTING HEIGHTS SHALL BE AS INDICATED UNLESS SHOWN OTHERWISE ON ELECTRICAL DRAWINGS OR ARCHITECTURAL ELEVATIONS NOT ALL SYMBOLS SHOWN ARE USED BUT ARE INDICATED FOR REFERENCE ONLY. <br />RECEPTACLES (MOUNTED 18" AFF TYP.)FLOOR BOXES <br />BRANCH CIRCUIT WIRING NOTES: <br />8-GANG RECESSED FLOOR BOX WITH DOUBLE DUPLEX RECEPTACLE, SUITABLE FOR AV, <br />POWER AND COMMUNICATION SERVICES. FLOOR BOX SHALL BE SUITABLE FOR <br />SLAB-ON-GRADE INSTALLATION. PROVIDE WIREMOLD EVOLUTION SERIES CATALOG <br />#EFB8SXX AND ALL REQUIRED DEVICE TRIMS AND COVER. COORDINATE TRIM COLORS <br />AND FINISHES WITH ARCHITECT. PROVIDE ALL CONDUIT STUB-OUTS AS REQUIRED FOR <br />TEL / DATA AND AV WIRING; COORDINATE WITH LOW VOLTAGE AND AV DRAWINGS. <br />F1 <br />FF FURNITURE FEED FLOOR BOX. PROVIDES LARGE CAPACITY FEEDS UP TO (2) INCHES, <br />TRADE SIZE KNOCKOUTS FOR AV, POWER, AND COMMUNICATION SERVICES. FLOOR BOX <br />SHALL BE SUITABLE FOR SLAB-ON-GRADE INSTALLATION. PROVIDE WIREMOLD <br />EVOLUTION SERIES CATALOG # EFBFF-OG, FPFFTCXX AND ALL REQUIRED DEVICE <br />TRIMS. COORDINATE TRIM COLORS AND FINISHES WITH ARCHITECT. PROVIDE ALL <br />CONDUIT STUB-OUTS AS REQUIRED FOR TEL / DATA AND AV WIRING; COORDINATE WITH <br />LOW VOLTAGE AND AV DRAWINGS. <br />HOMERUN TO PANELBOARD. "L43" INDICATES PANEL, "1,3" INDICATES CIRCUIT <br />NUMBERS, (20A, 1P, UNLESS INDICATED OTHERWISE) NUMBER OF SLASH MARKS <br />INDICATE NUMBER OF CONDUCTORS. <br />1. GREEN GROUND CONDUCTOR SHALL BE INCLUDED IN EACH RACEWAY. <br />SIZE SHALL BE A MINIMUM OF #12AWG. <br />2. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) <br />PHASE CONDUCTORS (ONE PER PHASE) PLUS NEUTRAL AND GROUND <br />CONDUCTORS IN EACH CONDUIT. <br />FEEDER TAG - REFER TO LEGEND OF FEEDER SIZES <br />LIGHTING FIXTURE CEILING OR RECESSED MOUNTED. "F1" INDICATES <br />FIXTURE TYPE, "2" INDICATES CIRCUIT NUMBER, "a" INDICATERS SWITCH CONTROL, <br />"E" INDICATES FIXTURE CONTAINS BATTERY BACK-UP FOR LIFE SAFETY <br />BARE LAMP STRIP OR INDUSTRIAL STRIP <br />FLUORESCENT UNDERCOUNTER TASK LIGHT <br />RECESSED OR SURFACE MOUNTED <br />LIGHTING FIXTURE <br />WALL MOUNTED LIGHTING FIXTURE <br />WALL WASH OR DIRECTIONAL LIGHTING FIXTURE <br />CEILING MOUNTED ILLUMINATED EXIT SIGN, ARROWS AS INDICATED ON DRAWINGS <br />WALL MOUNTED ILLUMINATED EXIT SIGN <br />SURGICAL EXAM LIGHT <br />EMERGENCY BATTERY UNIT <br />REMOTE EMERGENCY LIGHT HEADS <br />ARROW INDICATES TYPICAL LIGHTING FIXTURES IN CONTINUOUS ROW. FURNISH AND <br />INSTALL ALL CORNERS, ENDCAPS, EXTENSIONS AND FITTINGS AS RQUIRED FOR A <br />COMPLETE INSTALLATION <br />POLE MOUNTED SITE LIGHTING FIXTURE <br />BOLLARD TYPE SITE LIGHTING FIXTURE <br />SINGLE POLE TOGGLE SWITCH. "a" INDICATES FIXTURE CONTROL <br />DOUBLE POLE, DOUBLE THROW CENTER OFF TOGGLE SWITCH. HUBBELL SERIES <br />1382 <br />THREE WAY TOGGLE SWITCH <br />THREE WAY DIIMMER SWITCH <br />KEY OPERATED SWITCH <br />SINGLE POLE TOGGLE SWITCH WITH PILOT LIGHT <br />FAN SWITCH, FURNISHED BY HVAC SUBCONTRACTOR, INSTALLED AND WIRED BY <br />ELECTRICAL SUBCONTRACTOR <br />WALL MOUNTED OCCUPANCY SENSOR <br />THREE POSITION MOMENTARY CONTACT SWITCH, CENTER OFF <br />(MOUNTED 48" AFF) <br />JUNCTION BOX, SIZED PER NEC <br />PANELBOARD, SURFACE MOUNTED <br />LOAD-BREAK SWITCH <br />SOLID STATE TRIP UNIT <br />POTENTIAL TRANSFORMER <br />CURRENT TRANSFORMER <br />KIRK-KEY INTERLOCK <br />DRAW-OUT CIRCUIT BREAKER <br />CIRCUIT BREAKER <br />TRANSFORMER, SIZE AS INDICATED <br />FUSE, SIZE AS INDICATED <br />GROUND <br />PANELBOARD, FLUSH MOUNTED <br />DISTRIBUTION PANEL <br />MOTOR, "2" INDICATES HORSEPOWER <br />TWO GANG OUTLET BOX WITH MONITOR OUTLET AND ADJACENT DUPLEX <br />TWO GANG OUTLET BOX WITH TELEVISION ANTENNA OUTLET AND ADJACENT <br />ELECTRIC REHEAT COIL FURNISHED AND INSTALLED BY HVAC SUBCONTRACTOR, <br />BY ELECTRICAL SUBCONTRACTOR <br />CONNECTION TO AIR TERMINAL BOX MOUNTED ABOVE CEILING <br />CONNECTION TO OVERHEAD ROLL-DOWN DOOR. <br />ELECTRIC RADIANT HEATER, FURNISHED AND INSTALLED BY HVAC SUBCONTRACTOR, <br />RECEPTACLE. RUN 3/4" C FROM OUTLET BOX TO ABOVE NEAREST ACCESSIBLE <br />ACCESSIBLE CORRIDOR CEILING <br />WIRED BY ELECTRICAL SUBCONTRACTOR <br />LOW VOLTAGE TRANSFORMER, 120 VOLT TO 24 VAC <br />BUZZER/BELL, LOW VOLTAGE <br />PUSHBUTTON AND PLATE <br />CORRIDOR CEILING <br />WIRED BY ELECTRICAL SUBCONTRACTOR <br />DUPLEX RECEPTACLE. RUN 3/4" C FROM OUTLET BOX TO ABOVE NEAREST <br />CONNECTION TO MOTORIZED PROJECTION SCREEN MOUNTED ABOVE CEILING <br />60 MINUTE TIME SWITCH <br />ELECTRIC HEATER, FURNISHED AND INSTALLED BY HVAC SUBCONTRACTOR, WIRED <br />TRACK LIGHTING <br />DRY TYPE TRANSFORMER. "2" INDICATES SIZE, REFER TO DRY TYPE <br />TRANSFORMER SCHEDULE <br />CEILING MOUNTED OCCUPANCY SENSOR <br />C <br />1. OCCUPANCY SENSORS SHALL BE COMBINATION TYPE OF ULTRASONIC AND <br />PASSIVE INFARED DETECTION WITH INTERNAL PROCESSOR. <br />2. SENSOR SHALL BE INDEPENTENTLY ADJUSTABLE FOR INSTALLED CONDITIONS. <br />FRACTIONAL HORSEPOWER MOTOR-RATED SWITCH <br />DUPLEX RECEPTACLE, "R21" INDICATES PANEL, "2" INDICATES CIRCUIT NUMBER, <br />"E" INDICATES WIRED TO EMERGENCY PANEL <br />DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER TOP <br />DUPLEX RECEPTACLE WITH INTERGRAL GROUND FAULT INTERRUPTER <br />DUPLEX RECEPTACLE WITH INTERGRAL GROUND FAULT INTERRUPTER MOUNTED 6" <br />ABOVE COUNTER TOP <br />DOUBLE DUPLEX RECEPTACLE (AKA QUAD) <br />DUPLEX RECEPTACLE ONE HALF SWITCH CONTROLLED <br />SPECIAL PURPOSE RECEPTACLE, "2" INDICATES TYPE, SEE SPECIAL PURPOSE <br />RECEPTACLE SCHEDULE <br />FACTORY WIRED, UL LISTED, MULTIOUTLET ASSEMBLY. "24" INDICATES DUPLEX <br />RECEPTACLES MOUNTED ON 24" CENTERS <br />FIELD WIRED, UL LISTED, MULTIOUTLET ASSEBLY, DEVICES AS INDICATED <br />TWO DUPLEX RECEPTACLES MOUNTED AT 18" AFF AND 24" AFF <br />SIMPLEX (SINGLE) RECEPTACLE <br />SAFETY TYPE DUPLEX RECEPTACLE <br />R21-2 <br />E <br />GFI <br />GFI <br />DUPLEX RECEPTACLE SWITCHED VIA PLUG LOAD CONTROLLER. <br />LETTER "a" INDICATES ASSOCIATED PLUG LOAD CONTROLLER. <br />DUPLEX RECEPTACLE WITH INTEGRATED USB POWER OUTLETS. <br />a <br />TIMER SWITCH <br />A AMPERES <br />AF AMPERE FRAME (CIRCUIT BREAKER RATING) <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AIC AMPERE INTERRUPTING CAPACITY <br />AL ALUMINUM <br />ARCH ARCHITECT <br />AT AMPERE TRIP (CIRCUIT BREAKER RATING) <br />ATS AUTOMATIC TRANSFER SWITCH <br />AWG AMERICAN WIRE GUAGE <br />BLDG BUILDING <br />C CONDUIT <br />C.B. CIRCUIT BREAKER <br />C.T. CURRENT TRANSFORMER <br />CAT CATALOG <br />CIR CIRCUIT <br />COL COLUMN <br />CU COPPER <br />DEL DELTA <br />DWG DRAWING <br />E WIRED ON EMERGENCY CIRCUIT <br />EC EMPTY CONDUIT <br />EM EMERGENCY <br />ENL NEW LOCATION OF EXISTING TO BE RELOCATED DEVICE <br />ETD EXISTING TO BE DEMOLISHED AND REMOVED <br />ETR EXISTING TO REMAIN <br />ETRL EXISTING TO BE REMOVED AND REUSED/RELOCATED <br />F FLUSH <br />FT FEET <br />G GROUND <br />KCMIL ONE THOUSAND CIRCULAR MILS <br />KVA KILOVOLT-AMPERES <br />KVAR KILOVOLT-AMPERES REACTIVE <br />KW KILOWATTS <br />MCB MAIN CIRCUIT BREAKER <br />MCC MOTOR CONTROL CENTER <br />MISC MISCELLANEOUS <br />MLO MAIN LUGS ONLY <br />NC NORMALLY CLOSED <br />NEC NATIONAL ELECTRICAL CODE <br />NL NIGHT LIGHT <br />NO NORMALLY OPEN <br />NTS NOT TO SCALE <br />PH PHASE <br />P POLE <br />P.T. POTENTIAL TRANSFORMER <br />PVC POLYVINYL CHLORIDE <br />R RECESSED <br />S SURFACE <br />SCR SHORT CIRCUIT INTERRUPTING RATING <br />SP SPARE <br />SW SWITCH <br />TEL TELEPHONE <br />UG UNDERGROUND <br />V VOLT <br />Y WYE <br />W WATT <br />WP WEATHERPROOF <br />XFMR TRANSFORMER <br />CONNECTION TO WIRED PLUMBING ACCESORIES INCLUDING WIRES SINK SENSORS, PLUMBING <br />FLUSH VALVES, ELECTRIC SOAP DISPENSERS, ETC. COORDINATE LOCATION OF JUNCTION BOX (AND <br />CONCEALMENT THEROF) AND LOCATION OF ANY REQUIRED TRANSFORMERS OR OTHER <br />ACCESSORIES WITH THE VENDOR AND/OR ARCHITECT. <br />USB <br />2. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL OUTLETS INDICATED <br />CONDITIONS <br />WITH CIRCUIT NUMBERS AND PANEL DESIGNATIONS <br />3. ALL SWITCH CONTROLS SHALL BE PROVIDED WITH WIRING AND CONDUIT AS <br />THE INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING <br />CONDUIT SIZE TO ENSURE IT CAN ACCOMODATE ALL PHASE, NEUTRAL AND <br />GROUND CONDUCTORS. <br />5. A GREEN GROUNDING CONDUCTOR SHALL BE RUN WITH ALL CIRCUITS. VERIFY <br />1. WIRING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES OR SPECIAL <br />SYSTEM BE INSTALLED <br />4. ALTHOUGH ALL BRANCH CIRCUIT WIRING AND CONDUIT IS NOT SHOWN, IT IS <br />REQUIRED <br />CONNECTION TO ELECTRIC HAND DRYER <br />CONNECTION TO AUTOMATIC BLINDS. COORDINATE CONTROL, WIRING, TRANSFORMER TYPE AND <br />DEVICE PLACEMENT BLINDS VENDOR AND CEILING CONDITIONS. <br />FURNITURE FEED CONNECTION. CONNECTION TO ELECTRICAL FIXTURES, LIGHTS, ETC. <br />PROVIDED WITH CASEWORK OR FURNITURE. COORDINATE BEST LOCATION FOR JUNCTION <br />BOX AND WIRING REQUIREMENTS WITH CASEWORK/FURNITURE PROVIDER. ALL ELECTRICAL <br />CONDUITS, JUNCTION BOXES, ETC SHALL BE CONCEALED. WHERE THIS IS NOT POSSIBLE, <br />COORDINATE FINISHES OF ALL ELEMENTS WITH ARCHITECT. <br />CONNECTION TO PROJECTOR MOUNTED ABOVE CEILING. REFER TO TECH DRAWINGS FOR MORE INFORMATION. <br />CONNECTION TO ACCESS CONTROL TURNSTILE. COORDINATE LOCATION WITH ARCHITECT. <br />WALL MOUNTED DIMMER SWITCH. COORDINATE WITH FIXTURES FOR <br />DIMMING COMPATIBILITY. <br />CONNECTION TO LIT SIGNAGE. PROVIDE JUNCTION BOX IN ACCESSIBLE LOCATION ABOVE CEILING. <br />CONNECTION TO ELECTRIC WATER COOLER. COORDINATE CONNECTION TYPE WITH VENDOR/EQUIPMENT. <br />PROVIDE GFI PROTECTION (VIA GFI RECEPTACLE OR BREAKER). <br />DUPLEX RECEPTACLE FLOOR MOUNTED. COORDINATE TYPE/FINISH WITH ARCHITECT AND <br />OWNER. <br />60A/3PH/208V/F/NEMA 3R <br />DISCONNECT. "60A/3PH/208V/F/NEMA 3R" INDICATES 60A FRAME, 3 POLE, 208V, FUSIBLE, EXPOSURE RATING <br />"NEMA 3R". PROVIDE FUSIBLE DISCONNECT AND SIZE FUSE AS REQUIRED TO MEET MANUFACTURERS MOCP REQUIREMENTS. <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :3 1 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />E00-00 <br />ELECTRICAL LEGEND <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />ELECTRICAL SHEET INDEX <br />Sheet Number Sheet Name <br />E00-00 ELECTRICAL LEGEND <br />E00-01 LIGHTING FIXTURE SCHEDULE <br />E00-02 LIGHTING CONTROL INTENT 1 <br />E00-03 LIGHTING CONTROL INTENT 2 <br />E00-06 LIGHTING CONTROL DEVICE LOCATIONS <br />E01-01 ELECTRICAL SITE PLAN <br />E04-01 LEVEL 01 - ELECTRICAL DEMO <br />E04-02 LEVEL 02 - ELECTRICAL DEMO <br />E10-01 LEVEL 01 - ELECTRICAL LIGHTING PLAN <br />E10-02 LEVEL 01 - ELECTRICAL POWER PLAN <br />E11-01 LEVEL 02 - ELECTRICAL POWER PLAN <br />E42-01 ENLARGED KIOSK POWER & LIGHTING PLAN <br />E42-02 ENLARGED STORAGE POWER & LIGHTING PLAN <br />E42-03 ENLARGED KITCHEN POWER PLANS <br />E50-01 ELECTRICAL RISER DIAGRAM <br />E50-02 LIGHTING CONTROL RISER <br />E50-03 LIGHTING CONTROL RISER 2 <br />E70-01 PANEL SCHEDULES <br />E70-02 PANEL SCHEDULES <br />E90-01 ELECTRICAL DETAILS <br />FA00-00 FIRE ALARM LEGEND, NOTES & RISER <br />FA10-01 LEVEL 01 - FIRE ALARM PLAN <br />FA11-01 LEVEL 02 - FIRE ALARM PLAN <br />FA42-01 ENLARGED KIOSK, STORAGE, LAUNDRY FIRE ALARM PLAN <br />FA90-01 FIRE ALARM DETAILS <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018