My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment B - Sunny Isles Bldg Dept Annex, Bid Set
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(25-01-01) City Annex Building Construction Renovations
>
INVITATION TO BID 25-01-01 CITY ANNEX BUILDING CONSTRUCTION RENOVATIONS
>
Attachment B - Sunny Isles Bldg Dept Annex, Bid Set
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 9:15:56 AM
Creation date
2/20/2025 9:10:25 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
City Annex Building Construction Renovations
Bid No. (xx-xx-xx)
25-01-01
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire Alarm Riser DiagramE601http://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 <br />E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t sNOVEMBER 25, 2024CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011BID SETBUILDING DEPARTMENT RELOCATION <br />TO ANNEX <br />THIS ITEM HAS BEEN DIGITALLY SIGNED AND <br />SEALED BY ALEX ROBINSON ON THE DATE <br />ADJACENT TO THE SEAL. PRINTED COPIES OF <br />THIS DOCUMENT ARE NOT CONSIDERED SIGNED <br />AND SEALED AND THE SIGNATURE MUST BE <br />VERIFIED ON ANY ELECTRONIC COPIES.www.hammondengineers.com499 N.W. 70thAvenue,Suite 215Plantation, Florida 33317NEW FACP120VTWO(2) DEDICATED PHONELINES TO CONTROL STATIONSSSSINITIATION DEVICESSEE PLANS FOR LOCATIONAND QUANTITIESNOTIFICATION DEVICESSEE PLANS FOR LOCATIONAND QUANTITIESDDFTSFSGROUND1E-601FIRE ALARM RISER DIAGRAMScale: NTSFIRE ALARM SYSTEM NOTES:FFACPADDRESSABLE HEAT DETECTORADDRESSABLE PHOTOELECTRIC SMOKE FIRE ALARM CONTROL PANELFIRE ALARM SYMBOLS& ABBREVIATIONSELEVATOR RECALLRCPOST INDICATOR VALVEPIVADDRESSABLE MANUAL PULL STATION DETECTORADDRESSABLE DUCT DETECTORRREMOTE ALARM/TEST SWITCHTSFSTAMPER SWITCH (F.B.O.)FLOW SWITCH (F.B.O.)SPEAKER/STROBE DEVICESTROBE LIGHTRRELAYTMMONITOR MODULEFAAPFIRE ALARM ANNUNCIATOR PANELPS1FIRE ALARM POWER SUPPLY 1PS2FIRE ALARM POWER SUPPLY 2GENREMOTE GENERATOR PANELSSSURGE SUPPRESSION1.GENERAL ALARM ACTIVATION OF ALL PROGRAMMED SIGNAL CIRCUITS.2.LIGHT THE ASSOCIATED INDICATORS CORRESPONDING TO ACTIVE SIGNAL CIRCUITS.3.A GENERAL ALARM SHALL BE ANNUNICATED UPON ACTIVATION OF ANY PULL STATION, FLOW SWITCH & DETECTIONDEVICE. A TROUBLE SIGNAL SHALL BE ANNUNICATED UPON FAILURE OR REMOVAL OF A DETECTION OR MANUAL DEVICE. ASUPERVISORY SIGNAL SHALL ANNUNCIATE ANY TAMPER, HVAC, OR DUCT DETECTOR ACTIVATION.4.WATERFLOW SWITCH SHALL ACTIVATE GENERAL ALARM. A VALVE TAMPER SWITCH SHALL CAUSE A SYSTEM SUPERVISORYALARM INDICATION.5.ANNUNCIATION OF THE ACTIVE DEVICE AT THE FIRE ALARM CONTROL PANEL AND ANY ANNUCIATORS, IN MONITOREDBUILDING, SEND A SIGNAL TO THE U.L. CENTRAL STATION FOR ALARM, TROUBLE, WATERFLOW AND SUPERVISORYCONDITIONS.6.ACTIVATION OF ANY DUCT SMOKE DETECTORS SHALL INITIATE A SUPERVISORY CONDITION AT THE FIRE ALARM CONTROLPANEL. AN AUDIBLE SUPERVISORY TONE SHALL SOUND AT THE FIRE ALARM CONTROL PANEL AND THE SUPERVISORYLOCATION SHALL BE DISPLAYED AT THE CONTROL PANEL AND ANY REMOTE ANNUNCIATORS. THE SUPERVISORY SIGNALSHALL SHUTDOWN ALL ASSOCIATED HVAC UNITS IN THAT ZONE. THE SUPERVISORY CONDITION SHALL BE REPORTED TO AREMOTE SUPERVISORY STATION BY WAY OF AN APPROVED COMMUNICATOR FOR THE PURPOSES OF NOTIFICATION ANDACTION. GENERAL NOTES:1.SYSTEM SHALL BE ADDRESSABLE AND POWER LIMITED DESIGN, 24VDC.2.INITIATION CKTS WIRING SHALL BE #18 UNSHIELDED. TWISTED PAIR NOTIFICATION CIRCUITS WIRING SHALL BE #16THWN MIN. ALL WIRING TO BE IN FINAL COMPLIANCE WITH SUBMITTED AND APPROVED FIRE ALARM SHOPDRAWINGS. CONTRACTOR TO ADJUST CABLE TYPES AND SIZES AS REQUIRED.3.ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED N.E.C. ELECTRICAL TUBING AND SHALL BESEALED WITH U.L. APPROVE FIRE STOP MATERIAL.4.CONDUIT SHALL BE A MINIMUM OF 1/2" AND 40% FILL MAXIMUM.5.SMOKE DETECTOR SHALL NOT E LOCATED WITHIN 3' OF SUPPLY AIR OUTLETS.6.NOTIFICATION HORNS SHALL HAVE SOUND AT LEAST 15 dB ABOVE AVERAGE SOUND LEVEL OR 5 dB ABOVE THEMAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS MEASURED 5 FEET ABOVE FLOOR IN ALLOCCUPIED AREAS & STORAGE AREAS. THE CONTRACTOR SHALL CERTIFY THE dBA LEVEL WITH AN APPROVEDdBA METER PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.7.ALL FIRE ALARM DEVICES WHERE APPLICABLE SHALL HAVE A WHITE FINISH UNLESS OTHERWISE NOTED.8.FIRE ALARM PANEL SHALL HAVE 30% SPARE CAPACITY.9.A COMPLETE FIRE ALARM SYSTEM FOR THE FIRE STATION SHALL BE PROVIDED AS REQUIRED TO MEET LOCALCODES. THE FIRE ALARM SYSTEM SHALL BE DESIGNED AND INSTALLED BY A LICENSED FIRE ALARM SYSTEMCOMPANY AND SHALL HAVE THE LOCAL FIRE MARSHALL APPROVAL.10.ALL FIRE ALARM SYSTEM WIRING SHALL BE INSTALLED IN CONDUIT.11.PROVIDE SURGE PROTECTION AT ALL FIRE ALARM CIRCUITS EXTENDING BEYOND THE BUILDING PER NFPA 70ARTICLE 760.32.A.THE SCOPE OF THE FIRE ALARM SYSTEM INCLUDES THE FURNISHING, INSTALLATION CONNECTION AND TESTING OF AMICROPROCESSOR CONTROLLED, INTELLIGENT REPORTING FIRE ALARM SYSTEM. IT SHALL INCLUDE, BUT NOT BE LIMITED TO,ALARM INITIATING DEVICES, ALARM NOTIFICATION APPLIANCES, FIRE ALARM CONTROL PANEL (FACP), AUXILIARY CONTROLDEVICES, AND WIRING FOR A COMPLETE, OPERATIVE, COORDINATED SYSTEM.B.THE FIRE ALARM SYSTEM SHALL COMPLY WITH REQUIREMENTS OF THE LATEST ADOPTED EDITION OF NFPA STANDARD 72 FORPROTECTED PREMISES SIGNALING SYSTEMS AND FLORIDA FIRE PREVENTION CODE. THE SYSTEM SHALL BE ELECTRICALLYSUPERVISED AND MONITOR THE INTEGRITY OF ALL CONDUCTORS.C.THE FACILITY SHALL HAVE A NOTIFIER FIRE ALARM SYSTEM OR APPROVED EQUAL.D.THE FIRE ALARM SYSTEM COMPONENTS SHALL BE MANUFACTURED BY AN ISO 9001 CERTIFIED COMPANY AND MEET THEREQUIREMENTS OF BS EN9001: ANSI/ASQC Q9001-1994. EQUIPMENT CONSTRUCTED AND INSTALLED IN CONFORMITY WITH THISCODE SHALL BE LISTED FOR THE PURPOSE FOR WHICH IT IS USED (NFPA 72 SECTION 10.3.1 EQUIPMENT). MANUFACTURE SHALLPROVIDE THREE YEARS WARRANTY ON ALL FIRE ALARM EQUIPMENTS. FIRE ALARM CONTRACTOR SHALL HAVE BEEN IN BUSINESSFOR AT LEAST 5 YEARS.E.PROVIDE REMOTE TEST SWITCH AT EACH DUCT SMOKE DETECTOR. COORDINATE FINAL LOCATION IN THE FIELD.F.FIRE ALARM SEQUENCE OF OPERATION: ACTUATION OF ANY MANUAL STATION, SMOKE DETECTOR, HEAT DETECTOR ORDETECTION OF FIRE SPRINKLER WATERFLOW SHALL CAUSE THE FOLLOWING OPERATIONS TO OCCUR:DDFIRE ALARM NOTES:FIRE ALARM GENERAL NOTESCAFE TENANT1.FOR QUANTITY AND LOCATION OF FIRE ALARM DEVICES REFER TOFLOOR PLANS.2.ALL STROBE LIGHT SHALL BE 75 CANDELA UNLESS OTHERWISE NOTEDIN FLOOR PLAN.3.PROTECTIVE COVERS: PROVIDE AND INSTALL NRTL LISTED CLEARPOLYCARBONATE PROTECTIVE COVERS FOR ALL SMOKE DETECTORSBELOW 8'-6" AFF, AND ALL PULL STATIONS, STROBES, HORNS ANDHORN/STROBES EXCEPT THOSE LOCATED WITHIN ADMINISTRATIVE /STUDENT SERVICES STAFF OFFICES, UTILITY ROOMS AND STAFFRESTROOMS.4.IF FIRE ALARM SYSTEM IS INTERRUPTED FOR MORE THAN FOUR HOURS.A FIRE WATCH MUST BE PROVIDED.DDINITIATION DEVICES ON RTU'SSEE PLANS FOR LOCATIONAND QUANTITIESNOTIFICATION DEVICESSEE PLANS FOR LOCATIONAND QUANTITIESDDDDINITIATION DEVICES ON RTU'SSEE PLANS FOR LOCATIONAND QUANTITIESINITIATION DEVICESSEE PLANS FOR LOCATIONAND QUANTITIESFFAAPFAAP1.ALL FIRE ALARM DEVICES SHALL BE NEW AS NOTED.2.THE BATTERY BACK UP FOR ALARM AND SUPERVISORY FUNCTIONS SHALL BEBE ADEQUATE TO PROVIDE POWER AS REQUIRED BY CODE.3.THE FIRE ALARM CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF RECORDFOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO BCC, SIGNED ANDSEALED SHOP DRAWINGS AND CALCULATIONS BY A LICENSED FLORIDAPROFESSIONAL ENGINEER FOR FIRE ALARM SYSTEM.4.CONTRACTOR SHALL NOTIFY TO THE OWNER OR OWNERS REPRESENTATIVEAND A/E OF ANY EXISTING ALARM, SUPERVISORY OR TROUBLE CONDITION INTHE ALARM PANEL PRIOR TO COMMENCING WORK ON THE FIRE ALARM SYSTEM.ALARM PANEL SHALL BE CLEARED OF ALL TROUBLES BEFORE COMMENCINGWORK.5.UPON COMPLETION OF THE FIRE ALARM SYSTEM THE CONTRACTOR SHALLHAVE THE COMPLETE FIRE ALARM SYSTEM CERTIFIED.6.CAFE TENANT DEVICES AS SHOWN ON FLOOR PLAN AND RISER WILL BE FEDFROM SEPARATE NOTIFICATION APPLIANCE CIRCUITS AND SLC CIRCUITS ASINDICATED ON THIS RISER.7.ALL FIRE ALARM CIRCUITS SHALL BE PROVIDED WITH 2HR CIRCUIT INTEGRITYCABLE FOR 2HR FIRE RATING MEETING LEVEL 2 PATHWAY SURVIVABILITY INACCORDANCE WITH NFPA 72 FOR PARTIAL EVACUATION.8.INITIATION DEVICES IN THE CAFE SHALL ONLY ACTIVATE NOTIFICATIONAPPLIANCES IN THE CAFE, AND VICE VERSA FOR THE BUILDING DEPARTMENT.BUILDINGDEPARTMENTTENANT
The URL can be used to link to this page
Your browser does not support the video tag.