Laserfiche WebLink
CLERK #2WATER HEATERROOMELECTRICALROOMLIBRARY / FILES(FLOOR TO CEILING HEIGHT)CAFEEGRESSPLANPREPDESKLIBRARY / FILES <br />(FLOOR TO PARTITION HEIGHT) <br />LIBRARY / FILES <br />(FLOOR TO PARTITION HEIGHT)EGRESSCLERK #1EGRESS037RESTROOMWOMENS038RESTROOMMALE039RESTROOMWOMENS042UNISEXRESTROOM040RESTROOMMALE041CLOSETJANITOR036CLOSETJANITOR035STORAGE034ADMINISTRATORBUSINESS CENTER028PLAN EXAMINERSR. BUILDING027INSPECTOR026INSPECTOR013INSPECTORBUILDING006ADMIN005ADMIN032SUPERVISORPERMITCALL CENTER011003BREAKROOM008INSPECTORCHIEF PLUMBING014ADMINISTRATORFLOOD PLAIN007INSPECTORCHIEF BUILDING018INSPECTORSR. MECHANICAL009INSPECTORCHIEF MECHANICAL021INSPECTORELECTRICAL016INSPECTORPLUMBING023INSPECTOR020INSPECTORSR. ELECTRICAL002MANAGERBUILDING DEPT.010INSPECTORCHIEF ELECTRICAL025PLAN EXAMINERSR. BUILDING024INSPECTOR004BUILDING OFFICIALASSISTANT017ROOMCONFERENCE019INSPECTORMECHANICAL015INSPECTORSR. PLUMBING001OR DIRECTORBUILDING OFFICIAL043WAITING AREA044LOBBY / ENTRANCE029IT ROOM033SUPERVISORBUSINESS CENTER022ROOMMEETING031COORDINATORPLAN030PLAN EXAMINERSTRUCTURE012INSPECTORSR. BUILDINGK-6710WHITBYC_SINKSCAST IRON <br />K-6710WHITBYC_SINKSCAST IRON 3"6"1-1/2"3"1-1/2"2"1"1"2"3"3"3"1-1/2"1-1/2"1-1/2"1-1/2"1-1/2"2"2"2"1-1/2"1-1/2"1-1/2"1-1/2"1"2"1-1/2"1"1"1"1"1"1"1-1/2"1"1"1"1"1"1"1"1"EXISTING FIRE PROTECTION PIPING.NEW FIRE FIRE PROTECTION PIPING.NEW CONCEALED PENDANT SPRINKLER HEAD.FIRE SPRINKLER ARMOVER.AREA NOT IN SCOPE OF WORK. LOCATION OF THE EXISTING FIRE RISER ON EXTERIOR WALL. PROVIDE SHUT-OFF VALVE, FLOW, AND TAMPER SWITCH. COORDINATEWITH FIRE ALARM PLAN FOR MONITORING. NEW 3" FIRE SPRINKLER RISER UP THE BUILDING EXTERIOR.1NEW POINT OF CONNECTION. B. THIS DRAWING IS INTENDED AS A GUIDE TO BE USED IN THELAYOUT OF THE REMODEL OF THE 1ST FLOOR SPRINKLERDISTRIBUTION SYSTEM. THE CONTRACTOR MUST SUBMITDETAILED SHOP DRAWINGS IN CONFORMANCE WITH LOCAL CODEREQUIREMENTS AND MAY NOT PROCEED WITH THE WORK SHOWNTHEREON UNTIL APPROVED BY LOCAL AUTHORITIES HAVINGJURISDICTION.A. THE EXISTING BUILDING IS FULLY SPRINKLERED. SCOPE OF WORKINCLUDES CHANGES TO WALLS AND CEILING WHICH WILL RESULT INMINOR MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM.NEW UPRIGHT SPRINKLER HEAD.67C. EXISTING FIRE PROTECTION PIPING SHALL BE FIELD VERIFIED.FIRE PROTECTION RCPFP101ANNEX BUILDING FIRE PROTECTION RCP PLANSCALE: 3/16" = 1'-0"Nhttp://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 <br />E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t s <br />CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011BUILDING DEPARTMENT RELOCATION <br />TO ANNEXNOVEMBER 25, 2024PERMIT SETwww.hammondengineers.com499 N.W. 70thAvenue,Suite 215Plantation, Florida 33317THIS ITEM HAS BEEN DIGITALLY SIGNED AND <br />SEALED BY JOHN GRAY CUMPER ON THE DATE <br />ADJACENT TO THE SEAL. PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT CONSIDERED SIGNED AND <br />SEALED AND THE SIGNATURE MUST BE VERIFIED <br />ON ANY ELECTRONIC COPIES.