Laserfiche WebLink
A-502 <br />WALL SECTIONS CONT. <br />P.L. <br />AS SHOWN http://www.beai.comPHONE: (305) 461-2053LICENSE No. AA26001612Miami, Florida 3316811575 Northwest 7 AvenueFAX: (305) 634-0599 E-mail: info@beai.comBEA architects Inc.© NOVEMBER 2024 ADRIAN PRICE FL. LICENSE #AR97981CITY OF SUNNY ISLES BEACH18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011 <br />BID SET BUILDING DEPARTMENT RELOCATIONTO ANNEXFIRE WALL SECTION13/4"=1'-0" <br />WALL SECTION23/4"=1'-0" <br />A.P. <br />T.O. SLAB <br />EL. +0'-0" <br />T.O. FINISH FLOOR <br />EL. +0'-2 1/2" <br />T.O. SLAB <br />EL. +0'-0" <br />T.O. FINISH FLOOR <br />EL. +0'-2 1/2" <br />T.O. DOOR HEAD <br />EL. +8'-2 1/2" <br />T.O. BEAM <br />EL. +10'-2 1/8" <br />T.O. PARAPET <br />EL. +19'-4" <br />B.O. METAL DECK <br />EL. +13'-10 1/2" <br />T.O. PARAPET <br />EL. +19'-4" <br />WALL SECTION33/4"=1'-0" <br />T.O. SLAB <br />EL. +0'-0" <br />T.O. FINISH FLOOR <br />EL. +0'-2 1/2" <br />T.O. DOOR HEAD <br />EL. +8'-2 1/2" <br />T.O. BEAM <br />EL. +10'-2 1/8" <br />T.O. PARAPET <br />EL. +16'-0" <br />B.O. METAL DECK <br />EL. +13'-10 1/2" <br />NEW ROOF <br />T.P.O. <br />EXISTING <br />STRUCTURE <br />EXISTING <br />ROOF <br />031 028 <br />FINISH <br />FLOOR 2 1/2" <br />EXISTING <br />CONCRETE SLAB <br />(INTERIOR NOT IN SCOPE) <br />FUTURE LEASABLEAREA <br />045 <br />1,044 SQFT <br />EXISTING <br />STRUCTURE <br />GYPSUM BOARD <br />CEILING SEE RCP <br />EXISTING <br />ROOF <br />EXISTING <br />STRUCTURE <br />EXPOSED CEILING <br />SEE RCP <br />FIRE RATED CAULKING <br />AT INTERSECTION <br />POINTS ON WALL <br />FIRE RATED GYPSUM <br />BOARD TYPE X <br />FIRE RATED <br />GYPSUM BOARD <br />TYPE X <br />3" STUD AT 16" O.C. <br />FINISH <br />FLOOR 2 1/2" <br />EXISTING <br />CONCRETE SLAB <br />23 <br />WAITING AREA <br />043 <br />633 SQFT <br />GYPSUM BOARD <br />CEILING SEE RCP <br />4' WIDTH x 10' LENGTH x <br />1.625" THICK BALLISTIC <br />FIBERGLASS PANEL <br />(LEVEL 8) BY TOTAL <br />SECURITY SOLUTIONS <br />OR SIMILAR APPROVED <br />R13 FIBER GLASS <br />INSULATION S.T.C. 52 <br />1/2" RESILIENT <br />CHANNEL, 25GA, 24" <br />O.C. 2-1/2" STEEL <br />STUDS, EQ25, 24" O.C. <br />GYPSUM BOARD <br />CEILING SEE RCP <br />NEW STUCCO <br />NEW CONCRETE BEAM <br />SEE STRUCTURAL <br />NEW T.P.O. ROOF <br />NEW MIN.6" RIGID <br />INSULATION <br />NEW WOOD JOIST <br />SEE STRUCTURAL <br />NEW WOOD DECK <br />SEE STRUCTURAL <br />IT ROOM <br />029 <br />48 SQFT <br />ELECTRICALROOM <br />046 <br />59 SQFT <br />EXISTING ROOF <br />NEW METAL FLASHING <br />NEW STUCCO <br />NEW METAL PARAPET <br />CAP ON WOOD NAILER <br />GYPSUM BOARD <br />CEILING SEE RCP <br />GYPSUM BOARD <br />FURRING STRIP <br />WITH ALFOIL <br />R-4.1 <br />EXISTING 8" CMU <br />BLOCK <br />NEW CONCRETE SLAB <br />SEE STRUCTURAL <br />EXISTING STRUCTURE <br />NEW MASONRY BLOCK <br />EXISTING TO REMAIN <br />NEW ADDITION <br />GENERAL NOTES: <br />1. G.C. SHALL FIELD VERIFY ALL EXISTING <br />STRUCTURE INCLUDING DIMENSIONS, <br />LOCATION, & MATERIAL COMPOSITION. <br />SHADING LEGEND <br />EXPOSED BLOCK