Laserfiche WebLink
http://www.beai.comPHONE: (305) 461-2053LICENSE No. AA26001612Miami, Florida 3316811575 Northwest 7 AvenueFAX: (305) 634-0599 E-mail: info@beai.comBEA architects Inc.© NOVEMBER 2024 ADRIAN PRICE FL. LICENSE #AR97981CITY OF SUNNY ISLES BEACH18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011 <br />BID SET BUILDING DEPARTMENT RELOCATIONTO ANNEXP.L.A.P. <br />AS SHOWN <br />ROOF DETAILS <br />A-508 <br />OVERFLOW SCUPPER11-1/2"=1'-0" <br />EMERGENCY OVERFLOW SCUPPER21-1/2"=1'-0" <br />OVERFLOW DRAIN31-1/2"=1'-0" <br />TYP. PARAPET FLASING DETAIL63"=1'-0" <br />OVERFLOW SCUPPER81-1/2"=1'-0" <br />SEE SHEET A-500.1 <br />FOR WALL ASSEMBLIES <br />METAL COUNTER FLASHING <br />INSTALLED UNDER SHEATHING <br />4" H. X 8" W. METAL SCUPPER <br />W/ FLANGE ALL AROUND <br />SET ON ROOFING CEMENT <br />METAL CONDUCTOR <br />HEAD SECURED TO <br />WALL AS REQUIRED <br />METAL DOWN SPOUT <br />SEE PLUMBING DWGS. <br />FOR SIZE <br />2" - 16 GA METAL STRAPS <br />@48" O.C. MAX, <br />SECURED TO WALL W/ <br />1/4" DIA. CONC. <br />FASTENERS <br />BASKET STRAINER <br />METAL COUNTER <br />FLASHING SEE: A-509/6 <br />METAL FLASHING 4" MIN. <br />INTO SCUPPER AMD <br />EXTENDED 3" MIN. PAST <br />SCUPPER FLANGE. <br />NEW TPO ROOF.SEE <br />SHEET A-104 FOR NOA. <br />LIGHT WEIGHT <br />INSULATING CONC. DECK <br />OVER RIGID INSULATION <br />BOARD. OVER METAL <br />DECK. <br />NEW CMU BLOCK SEE <br />STRUCTURAL <br />DRAWINGS. <br />SEE SHEET A-500.1 <br />FOR WALL ASSEMBLIES <br />METAL COUNTER FLASHING <br />INSTALLED UNDER SHEATHING <br />4" H. X 8" W. EMERGENCY <br />OVERFLOW METAL SCUPPER <br />W/ FLANGE ALL AROUND <br />SET ON ROOFING CEMENT <br />METAL PARAPET CAP SECURED <br />TO NAILER W/ S.S. SCREWS AND <br />NEOPRENE WASHERS AT 12" O.C. <br />STAGGERED W/ 1-1/4" MIN <br />PENETRATION INTO CONC. <br />METAL COUNTER FLASHING <br />INSTALLED UNDER SHEATHING <br />P.T. WD. NAILERS <br />SECURED TO CONC. <br />SLAB CORDINATE NO. OF <br />PIECES WITH DEPTH OF <br />ROOF INSULATION.METAL COUNTER <br />FLASHING SEE: A-509/6 <br />METAL FLASHING 4" MIN. <br />INTO SCUPPER AMD <br />EXTENDED 3" MIN. PAST <br />SCUPPER FLANGE. <br />P.T. WD. NAILERS <br />SECURED TO CONC. <br />SLAB CORDINATE NO. OF <br />PIECES WITH DEPTH OF <br />ROOF INSULATION. <br />NEW TPO ROOF.SEE <br />SHEET A-104 FOR NOA. <br />LIGHT WEIGHT <br />INSULATING CONC. DECK <br />OVER RIGID INSULATION <br />BOARD. OVER METAL <br />DECK. <br />NEW CMU BLOCK SEE <br />STRUCTURAL <br />DRAWINGS. <br />EXISTING ROOF DRAIN COVER. <br />EXISTING METAL DECK. <br />EXISTING INSULATION BOARD. <br />NEW TPO ROOF.SEE SHEET <br />A-104 FOR NOA. <br />SLOPE <br />1/2" SLOPE <br />SLOPE <br />NEW TPO ROOF NOA: 19-1023.05 <br />CONT. METAL STUCCO <br />SHOULDER TYPE <br />COUNTER FLASHING <br />SECURED TO WALL W/ <br />S.S. SCREWS AND <br />WASHERS IN LEAD <br />SHEILDS @ 12" O.C. MAX. <br />STUCCO OVER 8" CMU <br />PARAPET. <br />CONT. FLASHING <br />MEMBRANE SECURED <br />TO BACK OF PARAPET <br />W/ FASTENERS. <br />CONT. P.T. WD. CANT. <br />NEW TPO ROOF.SEE <br />SHEET A-104 FOR NOA. <br />P.T. WD NAILER. <br />NAILED BASE SHEET <br />LIGHTWEIGHT INSULATING <br />CONC. DECK OVER C.I.P. <br />CONC. SLAB. <br />NAILED BASE SHEET <br />NEW TPO ROOF.SEE SHEET <br />A-104 FOR NOA. <br />CONT. METAL STUCCO <br />SHOULDER TYPE COUNTER <br />FLASHING SECURED TO WALL <br />W/ S.S. SCREWS AND <br />WASHERS IN LEAD SHEILDS <br />@ 12" O.C. MAX. <br />CONT. FLASHING MEMBRANE <br />SECURED TO BACK OF <br />PARAPET W/ FASTENERS. <br />STUCCO OVER 8" EXISTING <br />CMU PARAPET. <br />EXIST. METAL PARAPET CAP <br />SECURED TO NAILER W/ S.S. <br />SCREWS AND NEOPRENE <br />WASHERS AT 12" O.C. <br />STAGGERED W/ 1-1/4" MIN <br />PENETRATION INTO CONC. <br />1/2" SLOPE <br />EXISTING MODIFIED <br />BITUMEN ROOF <br />EXISTING CONT. METAL <br />STUCCO SHOULDER <br />TYPE COUNTER <br />FLASHING SECURED TO <br />WALL W/ S.S. SCREWS <br />AND WASHERS IN LEAD <br />SHEILDS @ 12" O.C. MAX. <br />EXISTING CONT. <br />FLASHING MEMBRANE <br />SECURED TO BACK OF <br />PARAPET W/ <br />FASTENERS. <br />EXISTING TILE OVER <br />PARAPET <br />PARAPET51-1/2"=1'-0" <br />SEE SHEET A-500.1 <br />FOR WALL ASSEMBLIES <br />METAL PARAPET CAP <br />SECURED TO NAILER W/ S.S <br />SCREWS AND NEOPRENE <br />WASHERS AT 12" O.C. <br />STAGGERED W/ 1-1/4" MIN <br />PENETRATION INTO CONC. <br />METAL COUNTER <br />FLASHING SEE: A-509/6 <br />METAL FLASHING 4" MIN. <br />INTO SCUPPER AMD <br />EXTENDED 3" MIN. PAST <br />SCUPPER FLANGE. <br />P.T. WD. NAILERS <br />SECURED TO CONC. <br />SLAB CORDINATE NO. OF <br />PIECES WITH DEPTH OF <br />ROOF INSULATION. <br />NEW TPO ROOF.SEE <br />SHEET A-104 FOR NOA. <br />LIGHT WEIGHT <br />INSULATING CONC. DECK <br />OVER RIGID INSULATION <br />BOARD. OVER METAL <br />DECK. <br />1/2" SLOPE <br />PARAPET41-1/2"=1'-0" <br />SEE SHEET A-500.1 <br />FOR WALL ASSEMBLIES <br />METAL PARAPET CAP <br />SECURED TO NAILER W/ S.S <br />SCREWS AND NEOPRENE <br />WASHERS AT 12" O.C. <br />STAGGERED W/ 1-1/4" MIN <br />PENETRATION INTO CONC. <br />METAL COUNTER <br />FLASHING SEE: A-509/6 <br />METAL FLASHING 4" MIN. <br />INTO SCUPPER AMD <br />EXTENDED 3" MIN. PAST <br />SCUPPER FLANGE. <br />P.T. WD. NAILERS <br />SECURED TO CONC. <br />SLAB CORDINATE NO. OF <br />PIECES WITH DEPTH OF <br />ROOF INSULATION. <br />EXISTING BITUMEN <br />ROOF <br />LIGHT WEIGHT <br />INSULATING CONC. DECK <br />OVER RIGID INSULATION <br />BOARD. OVER METAL <br />DECK. <br />1/2" SLOPE <br />TYP. FLASING AT RTU DETAIL73"=1'-0" <br />CONT. METAL COUNTER <br />FLASHING SECURED TO <br />WALL W/ S.S. SCREWS <br />AND WASHERS IN LEAD <br />SHEILDS @ 12" O.C. MAX. <br />CONT. FLASHING <br />MEMBRANE SECURED <br />TO BACK OF EXISTING <br />CURB. <br />CONT. P.T. WD. CANT. <br />NEW TPO ROOF.SEE <br />SHEET A-104 FOR NOA. <br />P.T. WD NAILER. <br />NAILED BASE SHEET <br />NEW RTU SEE <br />MECHANICAL DRAWINGS <br />FOR DETAILS. <br />ROOF PATCHING DETAIL91-1/2"=1'-0" <br />EXISTING ROOFASSEMBLY <br />LIGHT WEIGHT CONC. OVER <br />RIGID INSULATION BOARD <br />OVER METAL DECK. <br />NEW TPO ROOF.SEE SHEET <br />A-104 FOR NOA. <br />NEW LIGHT WEIGHT <br />CONC. W/ BONDING <br />AGENT. <br />NEW RIGID INSULATION <br />DEPTH TO COORDINATE <br />WITH EXISTING <br />INSULATION. <br />NEW METAL DECK LAPPED <br />OVER EXISTING METALDECK <br />1'-0" LAP BEYOND EXISTING <br />STRUCTURAL TRUSS. G.C. TO <br />PROVIDE SHOP DRAWINGS. <br />NEW METAL DECK LAPPED <br />OVER EXISTING METALDECK <br />1'-0" LAP BEYOND EXISTING <br />STRUCTURAL TRUSS. G.C. TO <br />PROVIDE SHOP DRAWINGS. <br />4' - 8" <br />EXISTING TO REMAIN <br />NEW ADDITION <br />GENERAL NOTES: <br />1. G.C. SHALL FIELD VERIFY ALL EXISTING <br />STRUCTURE INCLUDING DIMENSIONS, <br />LOCATION, & MATERIAL COMPOSITION. <br />SHADING LEGEND