Laserfiche WebLink
SAMSON OCEANFRONT PARK <br />CITY OF SUNNY ISLES <br />TECHNICAL SPECIFICATIONS <br /> <br /> <br />HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT 15061-2 <br /> <br />1. Description: MSS SP-58, Types 1 through 58, factory-fabricated components. <br />2. Galvanized Metallic Coatings: Pregalvanized or hot dipped. <br />3. Nonmetallic Coatings: Plastic coating, jacket, or liner. <br />4. Padded Hangers: Hanger with fiberglass or other pipe insulation pad or cushion to support \ <br />bearing surface of piping. <br />5. Hanger Rods: Continuous-thread rod, nuts, and washer made of carbon steel. <br /> <br />B. Stainless-Steel Pipe Hangers and Supports: <br />1. Description: MSS SP-58, Types 1 through 58, factory-fabricated components. <br />2. Padded Hangers: Hanger with fiberglass or other pipe insulation pad or cushion to support <br />bearing surface of piping. <br />3. Hanger Rods: Continuous-thread rod, nuts, and washer made of stainless steel. <br /> <br />C. Copper Pipe Hangers: <br />1. Description: MSS SP-58, Types 1 through 58, copper-coated-steel, factory-fabricated <br />components. <br />2. Hanger Rods: Continuous-thread rod, nuts, and washer made of copper-coated or steel <br />stainless steel. <br />2.02 <br /> <br />TRAPEZE PIPE HANGERS: <br />A. Description: MSS SP-69, Type 59, shop- or field-fabricated pipe-support assembly made from <br />structural carbon-steel shapes with MSS SP-58 carbon-steel hanger rods, nuts, saddles, and U- <br />bolts. <br /> <br />2.03 <br /> <br />THERMAL-HANGER SHIELD INSERTS: <br />A. Insulation-Insert Material for Cold Piping: ASTM C 552, Type II cellular glass with 100-psig <br />ASTM C 591, Type VI, Grade 1 polyisocyanurate with <br /> or <br />125-psig <br /> <br /> minimum compressive strength <br />and vapor barrier. <br />B. Insulation-Insert Material for Hot Piping: Water-repellent treated, ASTM C 533, Type I calcium <br />silicate with 100-psig ASTM C 552, Type II cellular glass with 100-psig or ASTM C 591, <br />Type VI, Grade 1 polyisocyanurate with 125-psig <br />C. For Trapeze or Clamped Systems: Insert and shield shall cover entire circumference of pipe. <br /> minimum compressive strength. <br />D. For Clevis or Band Hangers: Insert and shield shall cover lower 180 degrees of pipe. <br /> <br />E. Insert Length: Extend 2 inches <br /> temperature. <br /> beyond sheet metal shield for piping operating below ambient air <br /> <br />2.04 <br /> <br />FASTENER SYSTEMS: <br />A. Powder-Actuated Fasteners: Threaded-steel stud, for use in hardened portland cement concrete <br />with pull-out, tension, and shear capacities appropriate for supported loads and building materials <br />where used. <br />B. Mechanical-Expansion Anchors: Insert-wedge-type, zinc-coated steel anchors, for use in hardened <br />portland cement concrete; with pull-out, tension, and shear capacities appropriate for supported <br />loads and building materials where used.