<br /> <br />01510 - 1/5 <br />SECTION 01510 TEMPORARY UTILITIES AND FACILITIES <br />PART 1 - GENERAL <br />1.01 SUMMARY: <br />A. This Section includes requirements of a temporary nature not normally incorporated <br />into final Work. Temporary facilities and utilities are not required in this contract, <br />however, if the contractor is allowed, and provides temporary facilities, this section <br />shall apply. It includes the following: <br />1. Utility services. <br />2. Construction and support facilities. <br />3. Construction aids. <br />4. Fire protection. <br />B. Related Work Specified Elsewhere: <br />1. Barriers and Temporary Controls: SECTION 01530. <br /> <br />1.02 REFERENCES: <br />A. American National Standards Association (ANSI): <br />1. A10 Series - Safety Requirements for Construction and Demolition. <br />B. National Electrical Contractors Association (NECA): <br />1. Electrical Design Library - Temporary Electrical Facilities. <br />C. National Fire Protection Association (NFPA): <br />1. NFPA 10 - Portable Fire Extinguishers. <br />2. NFPA 70 - National Electrical Code. <br />3. NFPA 241 - Safeguarding Construction, Alterations, and Demolition <br />Operations. <br />D. National Electrical Manufacturers Association (NEMA). <br />E. Underwriters Laboratories (UL). <br />F. Florida Department of Transportation Standard Specifications for Road and Bridge <br />Construction. <br />G. Florida Trench Safety Act (90-96, Laws of Florida). <br />1.03 SUBMITTALS: <br />A. Site Plan: Submit to the City a Site Plan indicating Contractor's facilities including: <br />1. Trailers <br />2. Equipment Yard <br />3. Storage and lay-down <br />4. Parking <br />5. Traffic Control