Laserfiche WebLink
<br />EXHIBIT 1 <br />DESCRIPTION OF SPECIAL CONSTRUCTION <br /> <br />The Special Construction that is the subject of the Agreement to which this Exhibit 1 is <br />attached is as follows: <br /> <br />(1) Remove AT&T aerial cable from the FP&L and AT&T poles located along Collins <br />Avenue from 18Sth Street to 19Sth Street (the "Project Area"), including removal of <br />aerial service wire extending to customer premises along, and served by aerial cable <br />within, the Project Area ("Customer Premises"); (2) place underground cable and <br />service wire to replace the aerial cable and aerial service wire, resulting in conversion <br />of the aerial cable and service wire to underground; and (3) remove AT&T-owned <br />poles from the Project Area. <br /> <br />In addition to the conditions precedent to AT&T commencing the Special Construction <br />work identified in the Agreement to which this Exhibit 1 is attached, the following shall be <br />conditions precedent to AT&T commencing the work. <br /> <br />If any of these conditions precedent are not satisfied within six (6) months of the execution <br />of this Agreement, either party may terminate this Agreement by written notice to the <br />other party. In the event of such termination, AT&T shall return to the City any payment <br />received from the City for the work, except any portion of such payment to compensate <br />AT&T for any actual costs incurred for the work prior to termination. <br /> <br />A. (1) At no cost to AT&T, the City shall place, or shall have placed, the following <br />support structures along Collins Avenue for AT&T Florida's exclusive use (the <br />"Conduit") and shall have provided to AT&T as-built drawings showing the <br />precise location and nature of the Conduit, as installed: <br /> <br />Conduit as generally shown on drawings for job # 8MN03092B attached as <br />Attachment 1, as more specifically explained below: <br /> <br />· From an existing wood pole located west of Collins A venue and south of <br />Terracina Avenue centerlines to area north of the existing pavement. 1- 2" <br />PVC schedule 40 or better conduit, both ends to be identified in field with <br />markers. <br /> <br />· From an existing wood pole located east of Collins Avenue and north of <br />Terracina Avenue centerlines to an existing concrete pole located <br />approximately 175 feet south. 1-2" PVC schedule 40 or better conduit <br />with both ends identified in field with markers. <br /> <br />· From an existing pole located west of Collins A venue and east of Atlantic <br />Blvd. in line with existing utilities paralleling both streets (rear lot line) <br />