Laserfiche WebLink
<br /> <br />. <br /> <br />20. EXAMPLE PROJECT KEY <br />NUMBER <br /> <br />. ... ., <br /> <br />5 <br /> <br />21, TITLE AND LOCATION (City and State) <br />Capri South Beach Streetscape <br />Miami Beach, FL <br /> <br />22. YEAR COMPLETED <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br /> <br />2008 <br /> <br />2008 <br /> <br />mlrl:[.JIIJ:(II~"'j~I:I:If:t~~ll[.]~1 <br /> <br />a, PROJECT OWNER <br /> <br />b, POINT OF CONTACT NAME <br /> <br />c, POINT OF CONTACT TELEPHONE NUMBER <br />(317) 805-0707 <br /> <br />Maefield Development Ms. Mae Siffin <br />250 East 96th Street, Suite 580 <br />Indiana olis, Indiana 46240 <br />24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost) <br /> <br /> <br />~ Coastal Systems provided streetscape design services to improve the right- <br />of-way for 16th Street and Lincoln Terrace street ends as part of the Capri <br />South Beach Project. Capri South Beach encompasses three (3) distinctive <br />buildings on nearly 500 feet of waterfront on Biscayne Bay. <br /> <br />The streetscape improvements included decorative pavers along with parking, <br />sidewalks and landscaping to accommodate adjacent residences as part of the <br />overall neighborhood improvements. The Lincoln Terrace street end is <br />approximately 325 feet long and required a 12-inch water main extension. <br />Similarly, the 16th Street extension required an 8-inch water main extension and <br />slip lining of an existing 8-inch sanitary sewer line. <br /> <br />, Both street ends were low in elevation and adjacent to the bay and presented challenges for the drainage design. <br />Detailed topographic surveys were obtained to determine the drainage areas and an inverted-crown configuration <br />was selected. The drainage improvements included stormwater pumping stations connected to outfalls with <br />associated controls. <br /> <br />~~I;:I:l.]~~:(eJ.[.]~lIeJ <br /> <br />INVOLVED WITH if HIS <br /> <br />~:[.JJ:(!lIr <br />(3) ROLE <br />Prime <br /> <br />a. <br /> <br />(1) FIRM NAME <br /> <br />Coastal Systems International, Inc. <br /> <br />Cf.'.,:,..,.,'~,."'. <br />.....--_. <br />. ..-, <br />S I M' <br /> <br />(2) FIRM LOCATION <br />oral Gables, Florida <br /> <br />(1) FIRM NAME <br /> <br />(2) FIRM LOCATION <br /> <br />(3) ROLE <br /> <br />b. <br /> <br />(1) FIRM NAME <br /> <br />(2) FIRM LOCATION <br /> <br />(3) ROLE <br /> <br />c. <br /> <br />(1) FIRM NAME <br /> <br />(2) FIRM LOCATION <br /> <br />(3) ROLE <br /> <br />d. <br /> <br />(1) FIRM NAME <br /> <br />(2) FIRM LOCATION <br /> <br />(3) ROLE <br /> <br />e. <br /> <br />(1) FIRM NAME <br /> <br />(2) FIRM LOCATION <br /> <br />(3) ROLE <br /> <br />f. <br /> <br />STANDARD FORM 330 (1/2004) PAGE 3 <br />