<br />Copyright 2001 AIA <br /> <br />MASTERSPEC Short Form <br /> <br />02/01 (R 05106) <br /> <br />3.3 FIELD QUALITY CONTROL <br /> <br />A. Testing Agency: Owner will engage a qualified independent testing and inspecting agency to <br />inspect [field welds] [and] [high-strength holted connections]. <br /> <br />B. Bolted Connections: Shop-bolted connections will be[ tested and] inspected according to <br />RCSC's "Specification for Structural Joints Using ASTM A 325 or A 490 Bolts." <br /> <br />C. Welded Connections: Field welds will be visually inspected according to A WS Dl.1. <br /> <br />1. In addition to visual inspection, field welds will be tested according to A WS D 1.1 and the <br />following inspection procedures, at testing agency's option: <br /> <br />a. Liquid Penetrant Inspection: ASTM E 165. <br />b. Magnetic Particle Inspection: ASTM E 709; performed on root pass and on <br />fmished wdd. Cracks or zones of incomplete fusion or penetration will not be <br />accepted. <br />c. Ultrasonic Inspection: ASTM E 164. <br />d. Radiographic Inspection: ASTM E 94. <br /> <br />D. Correct deficiencies in Work that test reports and inspections indicate does not comply with the <br />Contract Documents. <br /> <br />END OF SECTION 05120END OF SECTION 05120 <br /> <br />STRUCTURAL STEEL <br /> <br />05120 - 6 <br />