Laserfiche WebLink
<br />2.01 MANUFACTURERS <br /> <br />A. Approved manufacturer's include, but are not limited to, the following: <br /> <br />1. Hanson Hardscape Products, Inc. <br />2. Paver Systems, Inc. <br /> <br />2.02 CONCRETE PAVERS <br /> <br />A. Paver blocks shall be composed of compressed concrete and meet or exceed <br />performance standards set by Hanson Paver Products, Inc. Pompano Beach, Florida or <br />approved equal. Pavers shall be in conformance with ASTM C936-82. <br /> <br />B. Color shall be selected by Consultant to include up to a 2 color scheme. <br /> <br />C. Concrete paver sizes shall be those necessary to construct the paving pattern as <br />recommended by the manufacturer. <br /> <br />D. All concrete pavers shall be shipped and packaged in pallets in accordance with <br />manufacturer's standard packaging procedures. Concrete pavers shall not be dumped at <br />the site. <br /> <br />E. Concrete pavers shall be kept protected, until they are installed, with weatherproof, non- <br />staining tarpaulins. Cracked, broken, stained, or otherwise damaged pavers will not be <br />acceptable in finished Work. <br /> <br />2.03 PAVER SEALER <br /> <br />A. Solvent based Acrylic Sealer - Crystal Clear Sealer by Cobble Coat, 1880 NW 18th St., <br />Pompano Beach, Florida 33069 (954) 971-9111. <br /> <br />2.04 MATERIAL MIXED FOR SETTING BED AND JOINTS <br /> <br />A. Bed and Joint Sand: Fine aggregate shall be clean, hard sand with durable particles and <br />free from adherent coatings, lumps of clay, alkali salts and organic matter. <br /> <br />PART 3 - EXECUTION <br /> <br />3.01 SETTING BED INSTALLATION <br /> <br />A. Place aggregate for compacted base over properly prepared and compacted subgrade. <br />Provide compacted thickness of base indicated to allow for thickness of leveling bed and <br />concrete paving units. Compact base to 95% of maximum dry density in accordance <br />with ASTM D 1557. <br /> <br />B. Place aggregate for leveling base and screed loose to a minimum thickness of 1-1/2", <br />taking care to ensure it remains loose until paving units are set and compacted. <br /> <br />C. Treat leveling base with suitable soil sterilizer to prohibit growth of grass and weeds. <br /> <br />D. Set concrete paving units hand tight, being careful not to disturb leveling base. Use <br />string lines to keep straight lines. Use block splitter to cut edges when full-size units <br />cannot be used. Select units from 4 or more cubes to blend color and texture variations. <br /> <br />PAGE 104 OF 130 <br />BID No. 08-10-01 <br />