My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(12-10-01) Newport Fishing Pier and Restaurant Utilities
>
Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/30/2012 11:09:24 AM
Creation date
10/30/2012 10:30:48 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Newport Fishing Pier and Restaurant Utilities
Bid No. (xx-xx-xx)
12-10-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
217
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. The epoxy compound shall be placed only when both the concrete surface <br /> temperature and the ambient temperature is 40 degrees F and rising. <br /> H. SAFETY <br /> 1. The Contractor shall require applicators to wear protective clothing, gloves, <br /> goggles and barrier creams. <br /> 3.05 OPENINGS IN CONCRETE <br /> A. Where openings are required for pipes, thimbles for gates, gate stems or other <br /> installations in existing concrete structures, the Contractor shall cut the existing <br /> concrete within the limits required, as shown on the Drawings or specified, expose <br /> the existing reinforcing steel and perform the work in such a manner as to prevent <br /> damage to the existing adjacent structures or equipment. <br /> B. Unless otherwise permitted, line drilling will be required. <br /> B. Where concrete is cut to provide openings for gate stems, pipe sleeves shall be <br /> accurately installed and grouted in place in an approved manner. <br /> 1. The exposed reinforcement shall be cleaned by wire brushing, then cut and <br /> bent to permit the installation and finally bent around the new pipe or <br /> thimble. Additional reinforcement shall be provided as shown on the <br /> Contract Drawings for typical reinforcing details of openings in walls and <br /> slabs, except as otherwise shown, specified or required. <br /> 2. After installation of pipelines and thimbles, etc., the existing concrete shall be <br /> prepared as specified above in Paragraph 3.03C and the void between the <br /> outside of the pipe or thimble and the existing concrete shall be filled with <br /> non-shrink grout. <br /> END OF SECTION <br /> 08/12 03700-5 11-4179 <br />