<br />
<br />CRAVEN THOMPSON & ASSOCIATES, INC. | 3563 NW 53rd STREET, FORT LAUDERDALE, FL 33309 | P 954.739.6400
<br />Patrick J. Gibney, P.E.
<br /> PROJECT ROLE | Principal-In-Charge
<br />EDUCATION Bachelor of Science - Civil Engineering
<br />Rutgers, The State University 1987
<br />REGISTRATIONS Professional Civil Engineer - Florida No. 49428 (1995)
<br />CERTIFICATIONS FDOT Pre-Qualified Roadway Construction Engineering Inspection
<br />YEARS OF EXPERIENCE 24 Years w/CTA 6 Years w/Other Firms
<br />AREAS OF EXPERTISE Civil Engineering
<br />SUMMARY OF EXPERIENCE
<br />Mr. Gibney has over thirty years of experience providing project management,
<br />design and construction management services for public civil engineering
<br />projects. These services include infrastructure improvements for a multitude of
<br />infrastructure rehabilitation projects. This includes pavement design, design of
<br />water distribution systems, sanitary sewer collection & transmission systems,
<br />storm water management systems, drainage systems, preparation of contract
<br />documents and specifications and construction inspections.
<br />
<br />WORK HISTORY
<br />Craven Thompson & Associates, Inc., Fort Lauderdale, Florida
<br />January 2014 to Present | Vice President, Engineering
<br />April 1993 to January 2014 | Senior Supervising Engineer
<br /> RELEVANT PROJECT EXPERIENCE
<br />North County Neighborhood Improvement Project, NE Quadrant, Bid Package 9 | Broward County, Florida
<br />| Project Manager. The North County Neighborhood Improvement Project (NCNIP) Northeast Quadrant,
<br />Bid Package 9 included approximately 152 acres of land between Dixie Highway and Federal Highway,
<br />north of Sample Road. Designed improvements included 38,863 linear feet of roadway, 23,000 linear
<br />feet of sidewalk, and 14,000 linear feet of swale, 6,560 linear feet of storm sewer, 8,920 linear feet of
<br />exfiltration trench and two (2) stormwater control structures, a reuse water distributi on system consisting
<br />of 22,000 linear feet of 4” diameter, and 1,800 linear feet of 12” diameter main, 57,000 linear feet of
<br />domestic water main and 40,000 linear feet of sanitary sewer collection and transmission systems.
<br />North County Neighborhood Improvement Projects, NE Quadrant Bid, Package 10 | Broward County,
<br />Florida | Project Manager. The North County Neighborhood Improvement Project (NCNIP) Northeast
<br />Quadrant, Bid Package 10 included approximately 213 acres of land. The project included 47,520
<br />linear feet of roadway reconstruction, and 53,460 linear feet of sidewalk construction. Also included
<br />were 15,283 linear feet of swale, 6,508 linear feet of storm sewer, and 8,074 linear feet of
<br />exfiltration trench. Several traffic calming devices were designed and constructed as part of this
<br />Project. A reuse water distribution system consisting of 32,900 linear feet was constructed on Bid
<br />Package 10, as well as approximately 4,740 linear feet of water main, 21 water services, 27,755
<br />linear feet of sanitary sewer collection and transmission lines, and 475 laterals.
<br />North Central County Neighborhood Improvements Project | Broward County, Florida | Project Manager
<br />Managed the design and permitting of the storm water treatment facilities, storm sewer systems, the
<br />water distribution systems, the sanitary sewer systems and the roadway modifications for the entire 980
<br />acres. Preparation of Basis of Design Report, Contract Document s, Permitting and Construction
<br />Management for 980-acre retrofit infrastructure improvements within unincorporated Broward County.
<br />This consisted of approximately 21 miles of roadway, 28,359 linear feet of sanitary lines, 21,308 linear
<br />feet of watermain, and 17.5 miles of sidewalk.
<br />F | Page 9
|