34 <br />14 <br />FPL APPROVED <br />CT METER <br />EXISTING <br />GROUND BUS <br />1-1/2" EC <br />4#250KCMIL, 1#3G IN 3-1/2"C <br />4#2 ,1#1G <br />#3/0 GROUND <br />4#250KCMIL, 1#3G IN 3-1/2"C <br />3P-1200A SERVICE <br />ENTRANCE 65KAIC <br />TWO SETS OF 4 <br />#350KCMIL IN 4"C <br />TWO SETS OF 4 <br />#350KCMIL IN 4"C <br />THREE SETS OF 4 <br />#600KCMIL IN 4"C <br />1#3_ <br />0 G TO 3_ <br />4"C TO (2)5_ <br />8"x10' GROUND <br />RODS SPACED 6 FEED PART, CWP AND <br />FOUNDATION STEEL <br />3P-600A <br />S/E RATED <br />65KAIC <br />3P-600A <br />S/E RATED <br />65KAIC <br />CTS DIST <br />PNL <br />"MDP" <br />(1 OF 3) <br />PNL <br />"P" <br />PNL <br />"S" <br />PNL <br />"AC" <br />PNL <br />"F" <br />EXISTING <br />PNL <br />"A" <br />TIME CLOCK (TYPICAL) <br />EXISTING FPL METER <br />600A (TYP OF 2)TVSS <br />T/C T/C <br />C C <br />(2 OF 3)(3 OF 3) <br />28 <br />28 <br />1616161616 <br />UTILITY VAULT (FPL) <br />MAIN ELECTRICAL ROOM INTERIOR <br />MAIN ELECTRICAL ROOM <br />EXTERIOR <br />LEVEL 02 <br />LEVEL 01 <br />100 <br />4" <br />4" <br />350 <br />400 <br />3 WIRE) WITH GROUND <br />CONDUCTORS (3 PHASE, <br />SYMBOL <br />FEEDER <br />3#6 & 1#10G. <br />3#4 & 1#8G. <br />3#1 & 1#8G. <br />3#1/0 & 1#6G. <br />3#1/0 & 1#6G. <br />3#2/0 & 1#6G. <br />3#3/0 & 1#6G. <br />3#4/0 & 1#4G. <br />3#250 KCMIL & 1#4G. <br />3#350 KCMIL & 1#4G. <br />3#500 KCMIL & 1#3G. <br />3#600 KCMIL & 1#3G. <br />6#250 KCMIL & 2#2G. <br />6#350 KCMIL & 2#1G. <br />1" <br />1" <br />1 1/2" <br />1 1/2" <br />1 1/2" <br />2" <br />2" <br />2" <br />2 1/2" <br />3" <br />3 1/2" <br />3 1/2" <br />2-2 1/2" <br />2-3" <br />COPPER CONDUCTORS <br />2-3" <br />2-3" <br />3" <br />3" <br />2 1/2" <br />2" <br />2" <br />2" <br />2" <br />1 1/2" <br />1 1/4" <br />1 1/4" <br />4 WIRE) WITH GROUND <br />CONDUCTORS (3 PHASE,RACEWAY <br />SIZE <br />CONDUIT <br />RACEWAY <br />SIZE <br />CONDUIT <br />NOMINAL <br />AMPERE <br />RATING <br />60 <br />70 <br />125 <br />150 <br />175 <br />200 <br />225 <br />250 <br />300 <br />500 <br />600 <br />8#350 KCMIL & 2#1G. <br />8#250 KCMIL & 2#2G. <br />4#600 KCMIL & 1#3G. <br />4#500 KCMIL & 1#3G. <br />4#350 KCMIL & 1#4G. <br />4#250 KCMIL & 1#4G. <br />4#4/0 & 1#4G. <br />4#3/0 & 1#6G. <br />4#2/0 & 1#6G. <br />4#1/0 & 1#6G. <br />4#1/0 & 1#6G. <br />4#1 & 1#8G. <br />4#4 & 1#8G. <br />4#6 & 1#10G. <br />6#600 KCMIL & 2#1/0G.2-3 1/2" <br />2-4" <br />800 <br />8#600 KCMIL & 2#1/0G. <br />31 <br />32 <br />33 <br />34 <br />35 <br />36 <br />9#400 KCMIL & 3#2/0G. <br />9#600 KCMIL & 3#3/0G. <br />12#600 KCMIL & 4#4/0G. <br />3-3" <br />3-3 1/2" <br />4-3 1/2" <br />4-4" <br />3-4" <br />3-3" <br />1000 <br />1200 <br />1600 <br />16#600 KCMIL & 4#4/0G. <br />12#600 KCMIL & 3#3/0G. <br />12#400 KCMIL & 3#2/0G. <br />20#600 KCMIL & 5#250 KCMIL G. <br />5-3 1/2" <br />38 <br />37 15#600 KCMIL & 5#250 KCMIL G. <br />5-4" <br />2000 <br />39 <br />40 <br />2500 <br />6-3 1/2"18#600 KCMIL & 6#500 KCMIL G. <br />41 <br />42 <br />3000 <br />24#600 KCMIL & 8#500 KCMIL G. <br />6-4"24#600 KCMIL & 6#500 KCMIL G. <br />8-3 1/2" <br />32#600 KCMIL & 8#500 KCMIL G.8-4" <br />43 <br />44 <br />4000 <br />40#600 KCMIL & 10#500 KCMIL G.10-4" <br />30#600 KCMIL & 10#500 KCMIL G.10-3 1/2" <br />PNL <br />"CCWDP" <br />PNL <br />"CCER" <br />PNL <br />"CCKP" <br />PNL <br />"CCEL" <br />PNL <br />"CCWR" <br />PNL <br />"CCWL" <br />EC SHALL FIELD VERIFY CONDUCTOR <br />SIZE. IF SMALLER THAN SHOWN, PULL <br />NEW FEEDERS. <br />SCOPE <br />OF <br />WORK <br />PNL <br />"CCEDP" <br />1 <br />1 122 <br />2 <br />POWER RISER DIAGRAM NOTES: <br />1. REFER TO PANEL SCHEDULES FOR MORE INFORMATION <br />2. PROVIDE SHUNT TRIP UNITS FOR ALL ELEVATOR MAIN POWER DISCONNECTS <br />3. GROUND ALL TRANSFORMERS AS INDICATED IN DRY TYPE TRANSFORMER <br />SCHEDULE <br />4. REFER TO DRY TYPE TRANSFORMER SCHEDULE FOR WIRING AND <br />GROUNDING OF ALL TRANSFORMERS <br />5. REFER TO GROUNDING DETAIL FOR SERVICE GROUND INFORMATION <br />6. ALL EMERGENCY, LEGALLY REQUIRED, LIFE SAFETY, & ELEVATOR FEEDERS <br />MUST BE 2HR RATED (EITHER LOCATED IN 2HR RATED ENCLOSURE OR PROVIDE <br />MI CABLE). <br />7. THE 'H' DISTRIBUTION REQUIRES THE TRANSFORMER TO BE PROVIDED WITH <br />EITHER FACTORY OR FIELD INSTALLED HARMONIC SUPPRESSION FILTER EQUAL <br />TO HARMONIC LIMITED - SYSTEM MAX. <br />8. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED ABOVE FLOOD LEVEL <br />ELECTRICAL KEYNOTES: <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />23 <br />24 <br />25 <br />26 <br />27 <br />28 <br />LEGEND OF FEEDER SIZES <br />29 <br />30 <br />PROVIDE METERING TO ACHIEVE FBC 6TH ED (ASHRAE 90.1) REQUIREMENTS: METERING OF THE FOLLOWING LOADS: <br />RECEPTACLE, INTERIOR LIGHTING, EXTERIOR LIGHTING, HVAC <br />FOUNTAIN <br />EQUIPMENT <br />ENCLOSURE <br />COMMUNITY CENTER <br />ELEC RM WEST <br />KITCHENCOMMUNITY CENTER <br />ELEC RM EAST <br />CONCESSION <br />STAND <br />REMOVE EXISTING PANELS "R1" AND "R2" AND INSTALL NEW PANELS REUSING EXISTING FEEDERS. CONTRACTOR SHALL VERIFY <br />THAT EXISTING FEEDERS ARE SIZED 600A (TWO SETS OF 350KCMIL) AS INDICATED ON THIS RISER. <br />KK <br />CCER CCEL <br />FA NAC <br />LCP <br />PROVIDE 5KVA EMERGENCY <br />LIGHTING INVERTER. <br />MYERS ILLUMINATOR IE SERIES <br />WITH 6 BREAKER <br />EC SHALL ENSURE 3FT CLEAR IN FRONT OF ALL <br />PANELS AND AS REQUIRED FOR INVERTER <br />SYSTEM. <br />EC SHALL COORDINATE WITH ARCHITECT BEFORE <br />ROUGHING IN WALLS / DOORS OR <br />INSTALLING OR ORDERING ANY EQUIPMENT. <br />ELEC. <br />118 <br />CCEDP <br />CCER-5 <br />CCER-1 <br />5 <br />LUTRON <br />SHADE/BLIND <br />CONTROL PANEL <br />HH <br />CCWL <br />FA NAC <br />CCWR LCP <br />CCWDP <br />ELECTRICAL <br />123 <br />CCWR-3 <br />CCWR-1 <br />CCLSI <br />PANELBOARD NAMING CONVENTION KEY <br />CCEL <br />COMUNITY CENTER <br />EAST <br />LIGHTING <br />CC=COMMUNITY CENTER <br />E=EAST, W=WEST, K=KITCHEN <br />L=LIGHTING, R=RECEPTACLES, P=POWER, M=MECHANICAL <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :5 1 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />E50-01 <br />ELECTRICAL RISER <br />DIAGRAM <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />1/4" = 1'-0"1 ENLARGED EXISTING MAIN ELECTRICAL ROOM <br />1/4" = 1'-0"3 ENLARGED NEW ELECTRICAL ROOM EAST <br />1/4" = 1'-0"2 ENLARGED NEW ELECTRICAL ROOM WEST <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018
The URL can be used to link to this page
Your browser does not support the video tag.