AUXILIARY 24V POWER <br />(AS REQUIRED) <br />AUXILIARY 24V POWER <br />(AS REQUIRED) <br />CMMM <br />CM CM <br />CM CMCMMMMM CM CMMM <br />FIRE <br />FIRE ALARM <br />ANNUNCIATOR <br />1 <br />2 <br />3 <br />4 <br />FIRE ALARM <br />PULL DOWNFIREFIGHTER'S <br />PHONE JACK <br />FSD <br />R J <br />R R <br />R R <br />R <br />R <br />R <br />FIRE ALARM DEVICE MOUNTING AND ELEVATIONS <br />FINISHED <br />FLOOR <br /> 0'-6" <br />MIN. <br />7'-0" <br />ABOVE THE <br />FINISHED <br />FLOOR <br />FINISHED <br />WALL- WALL-MOUNT APPLIANCE - <br />ENTIRE STROBE SHALL BE <br />80-96" ABOVE THE FINISHED <br />FLOOR <br />DOOR <br />WIDTH <br />LESS 3" <br />WALL MOUNTED SMOKE, <br />HEAT, OR CARBON <br />MONOXIDE (CO) DETECTOR <br />NOTE: MEASUREMENTS <br />SHOWN ARE TO THE <br />CLOSEST EDGE OF THE <br />DETECTOR <br />A/C <br />SUPPLY, <br />RETURN, <br />OR <br />EXHAUST <br />DIFFUSER <br />3'-0" <br />MIN. <br />CEILING MOUNTED SMOKE, <br />HEAT, OR CARBON <br />MONOXIDE (CO) DETECTORWALL MOUNT AUDIO/VISUAL APPLIANCE 6" <br />MINIMUM FROM CEILING <br />(24" MINIMUM-SLEEPING ROOMS ONLY) <br />WALL-MOUNT <br />NOTIFICATION <br />APPLIANCE <br />CEILING <br />0'-4" MIN. <br />1'-0" MAX. <br />MAGNETIC <br />DOOR <br />HOLDER <br />(WALL MOUNT SHOWN) <br />REMOTE ALARM <br />INDICATOR/TEST <br />STATION <br />42" MIN. - 48" MAX <br />5'-0" <br />MAX.MANUAL <br />PULL <br />STATION <br />~48" ABOVE <br />THE FINISHED <br /> FLOOR <br />~60" ABOVE THE FINISHED <br />FLOOR <br />NOTES: <br />DIMENSIONS SHOWN TO CENTERLINE OF DEVICE UNLESS OTHERWISE NOTED.1. <br />COORDINATE EXACT DEVICE LOCATIONS AND BACKBOX/MOUNTING REQUIREMENTS WITH THE ARCHITECTURAL ELEVATIONS, MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS, THE SYSTEM SUPPLIER'S SHOP DRAWINGS, AND THE WORK OF RELATED TRADES. <br />2. <br />FIREFIGHTER'S <br />TELEPHONE/JACK <br />CEILING MOUNTED REMOTE <br />ALARM INDICATOR/TEST STATION <br />SCALE: N.T.S. <br />ANY VISUAL NOTIFICATION APPLIANCE LOCATED LESS THAN 6" FROM THE CEILING (24" IN SLEEPING ROOMS) SHALL BE TREATED AS A <br />CEILING-MOUNTED DEVICE. <br />3. <br />FIRE/SMOKE DAMPER INTERFACE SCALE: N.T.S. <br />FROM <br />FACP <br />OPEN <br />MONITOR DAMPER <br />POSTION <br />DUCTWORK <br />120V LIFE SAFETY/ <br />EMERGENCY CIRCUIT <br />ADDRESSABLE <br />SIGNALING LINE CIRCUIT (SLC) <br />COORDINATE DAMPER POSITION/CONTROL POINT SCHEDULES WITH DIVISION 25 AND APPLICABLE SMOKE CONTROL <br />PROVISION OF DIVISION 28 FIRE/LIFESAFETY EMERGENCY COMMUNICATIONS SYSTEM. <br />1. <br />NOTES: <br />PROVIDE THE FOLLOWING AT EACH LOCATION IDENTIFIED: <br />120 VOLT CIRCUIT FROM THE LIFE SAFETY/EMERGENCY PANELBOARD AS INDICATED ON THE RISER DIAGRAM, ASSOCIATED <br />CONTROL MODULE/RELAY AND MONITOR MODULE(S) TO SUPERVISE DAMPER POSITION. <br />2. <br />ACTIVATION OF A SMOKE DETECTOR ASSOCIATED WITH A SMOKE DAMPER SHALL: <br />SEQUENCE OF OPERATION: <br />DETECTOR SHOWN FOR REFERENCE ONLY; MAY APPLY TO IN-DUCT OR AREA DETECTION ASSOCIATED WITH THIS DEVICE. <br />REFER TO FLOOR PLANS FOR ACTUAL SMOKE DETECTOR TYPES/LOCATIONS; COORDINATE ACTUAL DETECTOR QUANTITIES <br />WITH DUCT SIZES TO COMPLY WITH NFPA 72 SPACING REQUIREMENTS. <br />3. <br />SHOWN FOR <br />REFERENCE ONLY A. REPORT AS A SUPERVISORY DUCT SMOKE DETECTOR ACTIVATION (DUCT-MOUNTED DETECTOR ONLY) <br />B. INITIATE CLOSURE OF THE ASSOCIATED SMOKE DAMPER OR COMBINATION FIRE/SMOKE DAMPER <br />C. UNDER NORMAL OPERATION, FIRE/SMOKE DAMPERS SHALL BE OPENED UPON RECEIPT OF A REQUEST TO START SIGNAL, BE PROVEN OPEN <br />WHILE THE FAN IS ON AND CLOSE WHEN THE FAN IS OFF. <br />D. ANY DIS-ARRANGEMENT OF THE NORMAL OPERATION SHALL BE REPORTED AS A SYSTEM TROUBLE CONDITION. <br />DUCT SMOKE/AHU INTERFACE <br />FROM <br />FACP <br />AHU/FAN SHUTDOWN <br />ADDRESSABLE <br />SIGNALING LINE CIRCUIT (SLC) <br />SMOKE DETECTOR SHUTDOWN SIGNAL TO <br />ATC/BMS (SEE NOTE 2) <br />PROVIDE THE FOLLOWING AT EACH LOCATION IDENTIFIED: <br />SMOKE DETECTOR LOCATED IN THE DUCT/UNIT, TWO (2) ASSOCIATED CONTROL/RELAY MODULES. <br />COORDINATE DPDT RELAY OR DUAL CONTROL/SIGNAL INTERFACE TO SUPPORT SIMULTANEOUS EQUIPMENT CONTROL AND <br />DIRECT BAS INTERFACE TO REPORT FIRE ALARM-INITIATED EQUIPMENT SHUTDOWN. <br />2. <br />COORDINATE OUTPUT/RATING <br />REQUIREMENTS WITH DIVISION 25 <br />1. <br />NOTES: <br />AIR-HANDLING UNIT <br />(AHU) <br />COORDINATE ACTUAL DETECTOR QUANTITIES WITH DUCT SIZES TO COMPLY WITH NFPA 72 SPACING REQUIREMENTS.3. <br />ACTIVATION OF AN IN-DUCT SMOKE DETECTOR LOCATED AT A FAN OR AIR-HANDLING UNIT SHALL: <br />SEQUENCE OF OPERATION: <br />A. REPORT AS A SUPERVISORY DUCT SMOKE DETECTOR ACTIVATION <br />B. INITIATE SHUTDOWN OF THE ASSOCIATED AIR-HANDLING UNIT/FAN <br />C. INITIATE SMOKE DETECTOR SHUTDOWN SIGNAL TO THE ATC/BMS SYSTEM <br />D. CAUSE ASSOCIATED SHAFT SMOKE DAMPERS TO CLOSE <br />SEE <br />NOTE 5 <br />MANUAL OVERRIDE CONTROL/SUPERVISION <br />MANUAL <br />START <br />("ON") <br />EQUIPMENT <br />CONTROLLER <br />(VFD SHOWN) <br />SIGNALING LINE CIRCUIT (SLC) TO NEXT <br />DEVICE <br />AUXILIARY 24V POWER <br />SMOKE DETECTOR <br />SHUTDOWN SIGNAL <br />VFD <br />FAN STATUS <br />FEEDBACK <br />50% DAMPERS OPEN <br />ALL DAMPERS OPEN <br />SIGNALS TO BAS <br />CONTROLLER <br />FROM <br />FACP <br />SCALE: N.T.S. <br />REQUEST TO <br />START SIGNAL <br />PROVIDE STATUS FEEDBACK FOR EACH CONTROLLED DEVICE CONDITION. (DIVISION 28 SHALL PROVIDE POWER AND WIRING MONITOR <br />MODULES FOR FAN STATUS AND MOTOR CONTACTOR STATUS FEEDBACK. DIVISION 25 TO PROVIDE FIELD WIRING AND INSTALLATION OF FAN <br />PRESSURE/CURRENT SWITCH). <br />PROVIDE CONTROL OUTPUT SIGNALS AND APPROPRIATELY RATED MULTI-VOLTAGE INTERPOSING RELAYS TO EQUIPMENT CONTROLLERS (SUCH <br />VFD ARRAY OR MCC) FOR EACH CONTROLLED DEVICE AS SHOWN. REFER TO MECHANICAL EQUIPMENT SCHEDULES FOR INDIVIDUAL FAN/ARRAY <br />ARRANGEMENTS. <br />UNSUPERVISED RELAYS SHALL BE LOCATED WITHIN 3' OF THE CONTROLLED DEVICE. <br />REFER TO HVAC PLANS AND EQUIPMENT SCHEDULES FOR ACTUAL LOCATIONS AND QUANTITIES OF DUCT SMOKE DETECTORS - COORDINATE <br />WITH HVAC REQUIREMENTS FOR EXACT SEQUENCING AND OPERATION. <br />1. <br />2. <br />3. <br />4. <br />NOTES: <br />SHOWN FOR REFERENCE ONLY. THE DUCT SMOKE DETECTOR AND SMOKE DETECTOR SHUTDOWN IS PROVIDED ON "DUCT SMOKE/AHU <br />INTERFACE DETAIL" (DUCT SMOKE DETECTOR NOT PROVIDED ON EXHAUST FANS). AHU OVERRIDE OFF SHALL BE PROGRAMMED THROUGH THE <br />SMOKE DETECTOR SHUTDOWN CONTROL MODULE. <br />5. <br />1. MANUAL OVERRIDE CONTROL (ON/ “HAND” OR OFF) OF AUTOMATIC AIR HANDLING UNIT/FAN SYSTEMS SHALL BE PROVIDED VIA AUXILIARY <br />(HOA) SWITCHES AND STATUS LED INDICATORS LOCATED AT THE MAIN FIRE ALARM CONTROL PANEL, FIRE COMMAND STATION, OR FIRE <br />COMMAND CENTER AS SHOWN AND SPECIFIED. FUNCTIONS SHALL OPERATE AS FOLLOWS: <br />SEQUENCE OF OPERATION: <br />A. UNDER NORMAL OPERATION, THE SWITCH SHALL BE MAINTAINED IN THE AUTO POSITION AND NORMAL HVAC OR BUILDING AUTOMATION <br />SEQUENCES WILL TAKE PLACE. WHERE IN-DUCTOR AREA SMOKE DETECTORS ARE INSTALLED TO SERVE THE ASSOCIATED EQUIPMENT, <br />ACTIVATION OF THE SMOKE DETECTORS SHALL TRANSMIT A SIGNAL TO CAUSE THE EQUIPMENT TO AUTOMATICALLY SHUT DOWN. <br />B. UPON TRANSFERRING OF AN HOA SWITCH TO THE ON OR OFF POSITION, PRIORITIZED FIRE ALARM SYSTEM OUTPUTS WILL BE SENT TO <br />INITIATE EQUIPMENT CONTROL VIA THE EQUIPMENT MOTOR STARTER, MOTOR CONTROL CENTER (MCC), VARIABLE FREQUENCY DRIVE (VFD) <br />OR HVAC/BUILDING AUTOMATION CONTROL SYSTEM, TO COMMAND THE DESIRED SYSTEM OPERATION. <br />C. ONCE A MANUAL OVERRIDE SIGNAL IS RECEIVED, THE EQUIPMENT WILL BE SEQUENCED AS REQUIRED BY DIVISION 25. STATUS FEEDBACK <br />WILL BE REPORTED VIA CURRENT SENSOR, DIFFERENTIAL PRESSURE SWITCH, OR OTHER ACCEPTABLE METHOD OF STATUS CONFIRMATION, <br />AND WILL BE TRANSMITTED TO THE FIRE ALARM SYSTEM VIA DEDICATED STATUS INPUT MODULES. <br />D. UPON RECEIPT OF THE CONFIRMATION SIGNAL, THE APPROPRIATE STATUS LED WILL ILLUMINATE AT THE HOA SWITCH TO INDICATE THE <br />SYSTEM'S ACTUAL STATUS. <br />E. ANY HOA SWITCH PLACED INTO MANUAL OVERRIDE POSITION (ON OR OFF) SHALL CAUSE A SYSTEM TROUBLE CONDITION TO BE REPORTED. <br />2. SPECIAL ATTENTION SHALL BE PAID TO ALL STATE AND LOCAL REQUIREMENTS, AND COORDINATION OF DIVISION 25 CONTROL SEQUENCES <br />AND SAFETIES TO ENSURE: <br />A. FIRE ALARM HOA SWITCHES WILL BE GIVEN HIGHEST PRIORITY, AND WILL BE PROGRAMMED TO OVERRIDE ALL SAFETIES EXCEPT HIGH STATIC <br />PRESSURE UNLESS OTHERWISE DIRECTED. <br />B. RUN STATUS OF FANS SHALL BE CONSTANTLY TRACKED AND REFERENCED TO THE STATUS OF ASSOCIATED FLOOR SMOKE DAMPERS WHICH <br />SHALL BE CONTROLLED ACCORDINGLY TO COMPLY WITH THE PROJECT REQUIREMENTS. <br />C. UNDER NORMAL OPERATION, ALL ASSOCIATED SMOKE DAMPERS MONITORED AND CONTROLLED BY THE FIRE ALARM SYSTEM SHALL BE OPEN <br />WHENEVER THE FAN IS ON, AND CLOSED WHEN THE FAN IS OFF. ANY DIS-ARRANGEMENT FROM THE NORMAL CONDITION SHALL REPORT AS A <br />SYSTEM TROUBLE CONDITION. <br />D. CONFIRM AND COORDINATE WHICH SYSTEMS WILL BE PROVIDED WITH THE REQUIRED MANUAL OVERRIDE ON AND OFF CAPABILITIES; IN <br />CERTAIN INSTANCES, OVERRIDE CONTROL OFF WILL NOT BE PROVIDED FROM THE FIRE HOA DUE TO OVERRIDING HEALTH AND SAFETY <br />CONCERNS. ALL WORK SHALL BE COORDINATED AND SUBJECT TO THE APPROVAL OF THE LOCAL FIRE OFFICIAL. <br />E. UPON RECEIPT OF THE 'REQUEST TO START' SIGNAL, THE FIRE ALARM SYSTEM SHALL COMMAND ASSOCIATED SMOKE DAMPERS TO THE OPEN <br />POSITION. ONCE FIFTY-PERCENT (50%) OF THE DAMPERS HAVE BEEN PROVEN OPEN, A PERMISSIVE SIGNAL SHALL BE TRANSMITTED TO THE <br />BAS/EQUIPMENT CONTROLLER TO PROCESS THE FAN START SEQUENCE. "ALL OPEN" SIGNAL SHALL INDICATE THAT ALL ASSOCIATED DAMPERS <br />HAVE REACHED THEIR FULL OPEN POSITION. <br />STOP <br />("OFF") <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :5 8 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />FA90-01 <br />FIRE ALARM DETAILS <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018
The URL can be used to link to this page
Your browser does not support the video tag.