3/8" DIAMETER THREADED <br />ROD & FINNED NUT <br />SI <br />D <br />E <br /> <br />R <br />A <br />I <br />L <br />SE <br />E <br /> <br />P <br />L <br />A <br />N <br />TYPICAL HOLD DOWN PLATE <br />HEAVY DUTY SUPPORT <br />CHANNEL/HANGER ASSEMBLY <br />(1-5/8" UNISTRUT EVERY 60") <br />"T" INTERSECTION <br />SHALL BE A RADIUS <br />CABLE TRAY SECTION <br />90° SHALL BE <br />A RADIUS CABLE <br />TRAY SECTION <br />CABLE TRAY "T" SECTION CABLE TRAY 90° SECTION <br />WIRE BASKET CABLE <br />TRAY DISTRIBUTION <br />SYSTEM <br />APPROVED <br />ANCHOR BOLT <br />THREADED ROD <br />PROTECTOR <br />TYPICAL HOLD <br />DOWN PLATE <br />3/8" DIAMETER <br />THREADED ROD <br />& FINNED NUT <br />HEAVY DUTY SUPPORT <br />CHANNEL/HANGER <br />ASSEMBLY (1-5/8" UNISTRUT <br />EVERY 60") <br />CEILING SLAB <br />TYPICAL WIRE BASKET TYPE STEEL <br />CABLE TRAY DISTRIBUTION SYSTEM <br />3/8" DIAMETER THREADED ROD <br />THREADED ROD (CABLE) PROTECTOR TO <br />EXTEND UP 6" FROM BOTTOM OF TRAY <br />HEAVY DUTY/HANGER <br />ASSEMBLY <br />SUPPORT CHANNEL EVERY 60" <br />(1-5/8" UNISTRUT EVERY 60") <br />ISOMETRIC VIEW <br />CL <br />E <br />A <br />R <br />A <br />N <br />C <br />E <br /> <br />( <br />T <br />Y <br />P <br />I <br />C <br />A <br />L <br />) <br />12 <br />- <br />I <br />N <br />C <br />H <br />E <br />S <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />(THIS WILL VARY PER PROJECT) <br />12" TRAY WIDTH <br />(T <br />H <br />I <br />S <br /> <br />W <br />I <br />L <br />L <br /> <br />V <br />A <br />R <br />Y <br /> <br />P <br />E <br />R <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />) <br />6" <br /> <br />S <br />I <br />D <br />E <br /> <br />R <br />A <br />I <br />L <br />72 SQUARE INCHES OF USABLE <br />CABLE TRAY AREA (SEE NOTE 1) <br />(THIS WILL VARY PER PROJECT) <br />THREADED <br />ROD PROTECTOR <br />NOTES: <br />1.MAINTAIN A CLEARANCE OF 12" BETWEEN TOP OF TRAY <br />AND CEILING STRUCTURE OR OTHER EQUIPMENT OR <br />RACEWAY. <br />2.MAINTAIN A CLEARANCE OF 12" BETWEEN AT LEAST ONE <br />SIDE OF THE TRAY AND NEARBY OBJECTS. <br />3.MAINTAIN A CLEARANCE OF 6" BETWEEN BOTTOM OF <br />CABLE TRAY AND CEILING GRID OR OTHER EQUIPMENT OR <br />RACEWAY. <br />WIRE BASKET CABLE <br />TRAY DISTRIBUTION <br />SYSTEM <br />TYPICAL FIRESTOPPING <br />SLEEVE SYSTEM SEE NOTE 1 <br />NON RATED OR RATED <br />PARTITION <br />WIRE BASKET CABLE TRAY <br />DISTRIBUTION SYSTEM <br />ACCESSIBLE CEILING (TYPICAL) <br />NOTE TO CONTRACTOR: COMBINED <br />USABLE AREA OF CONDUITS SHALL BE <br />EQUAL TO AREA OF TRAY INSTALLED. SEE <br />TABLE BELOW (TYPICAL) <br />PARTITION -SEE <br />ARCHITECTURAL <br />DRAWINGS <br />FIRESTOPPING SLEEVES FOR <br />HORIZONTAL CABLING -REFER TO <br />DRAWING T505 DETAIL 5 FOR <br />ADDITIONAL INFORMATION <br />FINISHED FLOOR -SEE PLAN <br />ACCESSIBLE CEILING - <br />SEE RCP <br />WIRE BASKET CABLE TRAY -SEE <br />PLANS FOR LOCATIONS AND <br />SIZES -REFER TO DETAIL 1 ON <br />THIS DRAWING FOR ADDITIONAL <br />INFORMATION. <br />EXTEND FIRESTOPPING SLEEVES <br />BEYOND PARTITION WALL INTO <br />ROOM A MIN. OF 3-INCHES - <br />TRANSITION DISTANCE <br />NUMBER OF <br />FIRESTOPPING SLEEVES <br />6" x 6" <br />TRAY SIZE <br />3 <br />12" x 4"4 <br />12" x 6"6 <br />18" x 4"6 <br />18" x 6"9 <br />24" x 4"8 <br />24" x 6"12 <br />WIRE BASKET CABLE TRAY SHALL <br />BE STOPPED 6" FROM PARTITION <br />ACCESSIBLE CEILING - <br />SEE RCP <br />WIRE BASKET CABLE TRAY <br />SHALL BE STOPPED 6" FROM <br />PARTITION <br />EXTEND FIRESTOPPING <br />SLEEVES BEYOND PARTITION <br />WALL INTO ROOM A MIN. OF 3- <br />INCHES -TRANSITION <br />DISTANCE. CONTRACTOR TO <br />PROVIDE WATERFALL RADIUS <br />FOR CABLE TRANSITION <br />STRESS RELIEF AT EACH <br />FIRESTOPPING SLEEVE. <br />6" MAX 6" MAX <br />FRAMING DETAIL -SIDE SECTION <br />FRAMING DETAIL -FRONT SECTION <br />TYPICAL SINGLE SLEEVE WALL <br />PLATE (USE APPROPRIATE WALL <br />PLATE FOR NUMBER OF SLEEVES) <br />INTUMESCENT MATERIAL <br />FIRE RATED <br />SLEEVECROSS BRACE STUD <br />TYPICAL 4"X4" FIRE RATED <br />SLEEVE -SEE PLANS <br />PARTITION -SEE <br />ARCHITECTURAL PLAN <br />CROSS BRACE STUDS MUST BE <br />INSTALLED ABOVE AND BELOW <br />ALL FIRE RATED SLEEVE UNITS <br />TYPICAL 5/5 SLEEVE WALL <br />PLATE SECURED TO STUDS <br />TYPICAL 4"X4" FIRE RATED <br />SLEEVE <br />TYPICAL STUD -SEE <br />ARCHITECTURAL PLAN <br />CROSS BRACE STUD <br />SLEEVE DETAIL -AXONOMETRIC VIEW <br />FRONT VIEW <br />TYPICAL 5/5 SLEEVE WALL AND <br />FLOOR PLATE ASSEMBLY <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />ERIK S WALKER P.E: #63929 <br />JOHN MOUDLER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />RICARDO DURAN P.E: #64768 <br />GLEN R. SEILER P.E: #83347 <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 <br />t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELECTRICAL + PLUMBING <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />1 2 /4 /2 0 1 8 8 :0 8 :0 9 A M <br />C :\_R e v i t \T E C H - G A T E W A Y - v 2 0 1 8 _a v i l l a n u e v a C B Y X V .r v t <br />T40-05 <br />COMMUNICATIONS <br />DETAILS <br />JJP <br />AMV <br />810495.000 <br />JJP <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />N.T.S.1 TYPICAL CABLE TRAY DETAILS <br />GENERAL REQUIREMENTS: <br />1.PROVIDE 4-INCH FIRESTOPPING SLEEVES AT PARTITION WALLS IN <br />ORDER TO PROVIDE CONTINUOUS PATHWAY THROUGH PARTITION <br />WALLS BETWEEN CABLE TRAY SUPPORT SYSTEMS. QUANTITY OF 4-INCH <br />(INSIDE DIAMETER) CONDUIT SLEEVES SHALL MEET OR EXCEED THE <br />USEABLE CABLE TRAY AREA IN SQUARE INCHES. <br />2.FIRESTOP ALL PARTITION WALL PENETRATIONS AND CONDUIT SLEEVES <br />WITH CERTIFIED FIRESTOP SYSTEM AS REQUIRED TO MAINTAIN THE <br />FIRESTOP AND FIRE RESISTIVE RATING REQUIREMENTS OF THE <br />PARTITION WALL IN ACCORDANCE WITH THE ARCHITECT. <br />N.T.S.3 PARTITION WALL PENETRATION DETAIL - NON FIRE RATED AND RATED <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />N.T.S.2 TYPICAL "EZ-PATH SERIES 44" SLEEVE DETAIL - FIRESTOPPED <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018