4-GANG SPACE RESERVED FOR A/V <br />2-GANG SPACE RESERVED FOR ELECTRICAL2-GANG SPACE RESERVED FOR COMMUNICATIONS <br />2" KNOCK OUT (TYPICAL) <br />3/4" KNOCK OUT (TYPICAL) <br />REMOVABLE MODULE WITH <br />(2) 2-GANG DEVICE <br />OPENINGS <br />TUNNEL SYSTEM FOR <br />CONNECTION BETWEEN <br />MODULES <br />WIREMOLD EVOLUTION 8 GANG <br />FLOORBOX -PROVIDED BY <br />ELECTRICAL CONTRACTOR <br />REMOVABLE MODULE WITH <br />(1) 4 GANG DEVICE OPENING <br />1-1/4" KNOCK OUT (TYPICAL) <br />SLAB <br />FINISHED CEILING -SEE RCP <br />FLOOR BOX DEVICE PROVIDED <br />BY ELECTRICAL CONTRACTOR <br />(1) 1" CONDUIT FOR ELECTRICAL <br />(2) 1-1/2" AND (1) 2" CONDUIT FOR AV <br />AND (1) 1-1/2" CONDUIT FOR <br />TELECOMMUNICATIONS <br />NOTE: <br />•ALL CONDUITS SHALL BE <br />PLACED IN CORE THROUGH <br />SLAB AND RETURN UP A <br />COMMON WALL WITHIN <br />ROOM AND THEN TO <br />ACCESSIBLE CORRIDOR <br />(TELECOMMUNICATIONS <br />ONLY) <br />•FURNISH AND INSTALL <br />CONDUIT ADAPTER <br />FITTINGS FOR FLOOR BOX <br />FOR COMPLETE <br />INSTALLATION AS NEEDED. <br />(2) 1-1/2" AND (1) 2" <br />CONDUIT TO STUB UP <br />WITHIN ROOM FOR AV <br />SYSTEMS. (1) 1" <br />CONDUIT STUB UP <br />WITHIN ROOM FOR <br />ELECTRICAL <br />CONNECTION. <br />(1) 1-1/2" CONDUIT TO STUB <br />WITHIN ACCESSIBLE <br />CORRIDOR CEILING FOR <br />TELECOMMUNICATIONS <br />T40-04 <br />1 <br />6" CABLE RUNWAY ELEVATION KIT <br />1/2" THREADED ROD TO STRUCTURE ABOVE <br />1-5/8"X7/8" UNISTRUT <br />L6-20R RECEPTACLE(TYPICAL) <br />5-20R DUPLEX RECEPTACLE(TYPICAL) <br />POWER FEED <br />ALA4800 WIREMOLD <br />POWER FEED <br />ALIGN TOP OF WIREMOLD <br />WITH TOP OF OVERHEAD <br />RUNWAY BEHIND <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />ERIK S WALKER P.E: #63929 <br />JOHN MOUDLER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />RICARDO DURAN P.E: #64768 <br />GLEN R. SEILER P.E: #83347 <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 <br />t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELECTRICAL + PLUMBING <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />1 2 /4 /2 0 1 8 8 :0 8 :0 7 A M <br />C :\_R e v i t \T E C H - G A T E W A Y - v 2 0 1 8 _a v i l l a n u e v a C B Y X V .r v t <br />T40-04 <br />COMMUNICATIONS <br />DETAILS <br />JJP <br />AMV <br />810495.000 <br />JJP <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />N.T.S.1 FLOOR BOX DETAIL <br />N.T.S.2 TELECOMMUNICATIONS CONDUIT PATHWAY FOR IN-SLAB FLOOR BOX <br />N.T.S.3 IDF RACK WIREMOLD RECEPTACLE LAYOUT <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018