My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-01-09_GATEWAY PARK CENTER_CONFORMED DRAWINGS FOR BID
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(19-01-01) Gateway Park Center
>
2019-01-09_GATEWAY PARK CENTER_CONFORMED DRAWINGS FOR BID
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:43:53 AM
Creation date
1/31/2019 11:23:07 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCESS/ENTRY SIDE <br />INTERIOR/EGRESS SIDE <br />JB <br />ACCESSIBLE CEILING <br />JUNCTION BOX ABOVE <br />ACCESSIBLE CEILING <br />CONCEALED <br />DOOR <br />CONTACT SWITCH <br />DOOR <br />FINISHED FLOOR <br />DC <br />DOOR FRAME <br />3/4" CONCEALED CONDUIT <br />TO ACCESS CONTROL PANEL <br />1-1/4" CONDUIT <br />18 AWG 2 CONDUCTOR WIRE <br />ACCESS/ENTRY SIDE <br />INTERIOR/EGRESS SIDE <br />ACCESSIBLE CEILING <br />TO ACCESS CONTROL <br />PANEL <br />JUNCTION BOX ABOVE <br />ACCESSIBLE CEILING <br />DC <br />JB <br />DOOR <br />CONCEALED DOOR <br />CONTACT SWITCH (TYPICAL) <br />DC <br />FINISHED FLOOR <br />DOOR FRAME <br />1-1/4" CONDUIT <br />3/4" CONCEALED CONDUIT <br />18 AWG 2 CONDUCTOR WIRE <br />ACCESSIBLE CEILING -SEE <br />ARCHITECTURAL RCP <br />CATEGORY CABLE TO NEAREST <br />TELECOMMUNICATIONS ROOM <br />CAMERA -REFER TO PLANS AND <br />SPECIFICATIONS FOR ADDITIONAL <br />INFORMATION <br />1" CONDUIT TO NEAREST <br />TELECOMMUNICATIONS ROOM <br />PROVIDE 4-11/16"x4-11/16"x3" BACK BOX <br />CATEGORY PATCH CORD <br />TO CAMERA <br />1-PORT SURFACE MOUNTED BOX <br />1G DEVICE PLATE <br />TYPICAL CAMERA HOUSING <br />CADDY 512A ADJUSTABLE <br />SNAP-ON CEILING BOX <br />HANGER <br />NOTE: ELECTRICAL CONTRACTOR, <br />ELECTRONIC SAFETY AND SECURITY <br />CONTRACTOR, AND ARCHITECT SHALL <br />COORDINATE PRIOR TO ROUGH-IN <br />INSTALLATION FOR SECURTY CAMERA <br />ATTACHMENT REQUIREMENTS TO BACKBOX <br />ASSEMBLY. <br />1" CONDUIT TO NEAREST <br />TELECOMMUNICATIONS ROOM <br />CATEGORY CABLE TO NEAREST <br />TELECOMMUNICATIONS ROOM <br />PROVIDE 4-11/16"x4-11/16"x3" BACK BOX <br />PARTITION -SEE <br />ARCHITECTURAL FLOOR PLANS <br />1-PORT SURFACE MOUNTED BOX <br />1G DEVICE PLATE <br />CAMERA HOUSING <br />CAMERA -REFER TO PLANS AND <br />SPECIFICATIONS FOR ADDITIONAL <br />INFORMATION <br />CATEGORY 6 PATCH CORD TO <br />CAMERA <br />NOTE: ELECTRICAL CONTRACTOR, ELECTRONIC <br />SAFETY AND SECURITY CONTRACTOR, AND <br />ARCHITECT SHALL COORDINATE PRIOR TO ROUGH- <br />IN INSTALLATION FOR SECURTY CAMERA <br />ATTACHMENT REQUIREMENTS TO BACKBOX <br />ASSEMBLY. <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />ERIK S WALKER P.E: #63929 <br />JOHN MOUDLER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />RICARDO DURAN P.E: #64768 <br />GLEN R. SEILER P.E: #83347 <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 <br />t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELECTRICAL + PLUMBING <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />1 2 /4 /2 0 1 8 8 :0 7 :4 8 A M <br />C :\_R e v i t \T E C H - G A T E W A Y - v 2 0 1 8 _a v i l l a n u e v a C B Y X V .r v t <br />SE40-01 <br />SECURITY DETAILS <br />JJP <br />AMV <br />810495.000 <br />JJP <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />N.T.S.3 SECURITY OPENING-SINGLE MONITORED DOOR <br />N.T.S.4 SECURITY OPENING-DOUBLE MONITORED DOOR <br />SECURITY -MASTER-MONITORED ONLY DOOR SCHEDULE <br />MO <br />N <br />I <br />T <br />O <br />R <br />E <br />D <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br /># <br />HE <br />A <br />D <br />- <br />E <br />N <br />D <br /> <br />R <br />O <br />O <br />M <br />DO <br />O <br />R <br /> <br />C <br />O <br />N <br />T <br />A <br />C <br />T <br />DE <br />T <br />A <br />I <br />L <br /> <br />N <br />U <br />M <br />B <br />E <br />R <br />IN <br />S <br />T <br />A <br />L <br />L <br />E <br />R <br /> <br />N <br />O <br />T <br />E <br />S <br />T. O GROUND LEVEL <br />121D EXISTING IDF 1 3/SE40-01 <br />E100 EXISTING IDF 2 4/SE40-01 <br />E121B EXISTING IDF 2 4/SE40-01 <br />E121C EXISTING IDF 2 4/SE40-01 <br />E-101 EXISTING IDF 2 4/SE40-01 <br />E-101C EXISTING IDF 2 4/SE40-01 <br />E-101D EXISTING IDF 2 4/SE40-01 <br />E-117B EXISTING IDF 2 4/SE40-01 <br />E-117C EXISTING IDF 2 4/SE40-01 <br />E-117D EXISTING IDF 2 4/SE40-01 <br />N.T.S.1 TYPICAL SECURITY CAMERA - CEILING MOUNTED <br />N.T.S.2 TYPICAL SECURITY CAMERA - WALL MOUNTED <br />SECURITY CCTV CAMERA SCHEDULE <br />SE <br />Q <br />U <br />E <br />N <br />T <br />I <br />A <br />L <br /> <br />N <br />U <br />M <br />B <br />E <br />R <br />HE <br />A <br />D <br />- <br />E <br />N <br />D <br /> <br />R <br />O <br />O <br />M <br />BO <br />D <br /> <br />M <br />O <br />D <br />E <br />L <br /> <br /># <br />CA <br />M <br />E <br />R <br />A <br /> <br />M <br />O <br />U <br />N <br />T <br />I <br />N <br />G <br /> <br />T <br />Y <br />P <br />E <br />DE <br />T <br />A <br />I <br />L <br /> <br />N <br />U <br />M <br />B <br />E <br />R <br />NO <br />T <br />E <br />S <br />T. O GROUND LEVEL <br />01-01 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-02 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-03 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-04 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-05 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-06 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-07 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-08 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-09 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-10 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-11 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-12 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-13 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-14 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />01-15 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-01 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-02 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-03 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-04 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-05 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-06 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-07 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-08 EXISTING IDF AXIS Q3708-PVE CEILING 1/SE40-01 <br />02-09 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-10 EXISTING IDF AXIS Q3708-PVE CEILING 1/SE40-01 <br />02-11 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-12 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-13 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />02-14 EXISTING IDF AXIS Q3518-LVE CEILING 1/SE40-01 <br />T. O GROUND LEVEL: 29 <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018
The URL can be used to link to this page
Your browser does not support the video tag.