Laserfiche WebLink
SCALE:N.T.S. <br />DUCT PENETRATION CONSTRUCTION DETAIL <br />GYPBOARD PARTITION MASONRY PARTITION <br />GYP BOARD WALL <br />CONSTRUCTION <br />MASONRY WALL <br />CONSTRUCTION <br />ACOUSTICAL SEALANT <br />SHEET METAL <br />ENCLOSURE <br />PACK W/ FIBERGLASS <br />INSULATION (3# TO 6# <br />DENSITY). <br />REF: $M15723 SCALE:N.T.S. <br />TYPICAL 90 DEG. DUCT TAP <br />WITH DAMPER BLADE DETAIL <br />CLINCH EDGES <br />BRANCH DUCT <br />AIR FLOW <br />TRUNK DUCT <br />45 DEGREE ANGLE <br />PROVIDE OPPOSED BLADE DAMPER AT ALL <br />LOW PRESSURE TAPS (DOWNSTREAM OF <br />VAV BOXES, EXHAUST & O/A DUCTS). <br />REF: $M15705 <br />SCALE: <br />SCALE: <br />SCALE:N.T.S. <br />ROUND DUCT TAKE-OFF DETAIL <br />AIR FLOW <br />SPIN-IN FITTING WITH DAMPER, 45° <br />EXTRACTOR AND LOCKING <br />QUADRANT. <br />FLEXIBLE CONNECTION <br />REF: $M15703 <br />SCALE:N.T.S. <br />FLEXIBLE DUCT CONNECTION DETAIL <br />AIR FLOW <br />DIFFUSER <br />LOW VELOCITY SUPPLY AIR DUCT <br />(SEE PLAN VIEW) <br />INSULATED FLEXIBLE DUCT <br />4" TO 6" HIGH METAL COLLAR ROUND <br />DUCT, WITH 1-1/2" LBS/1" THICK, MFR. <br />OWEN-CORNINGS, DUCT WRAP <br />INSULATION, TO PERMIT FLEXIBLE DUCT <br />CONN. AND OBD INSTALLATION <br />ATTACH COLLAR TO DIFFUSER NECK <br />W/ SCREWS 4" OC. SEAL JOINT W/ <br />DUCT SEALER AND TAPE. <br />MANUAL OPPOSED <br />BLADE DAMPER <br />SEAL JOINT WITH <br />DUCT SEALER & <br />TAPE. <br />REF: $M15709A SCALE:N.T.S. <br />FLEXIBLE DUCT CONNECTION DETAIL <br />AIR FLOW <br />LOW VELOCITY <br />SUPPLY AIR DUCT <br />(SEE PLAN VIEW) <br />SPIN-IN FITTING WITH <br />EXTRACTOR AND <br />QUADRANT DAMPER <br />INSULATED FLEX. DUCT <br />4" TO 6" HIGH METAL COLLAR <br />ROUND DUCT, WITH 1 1/2 " LBS/IN <br />THICK, MFR. OWEN-CORNINGS, <br />DUCTWRAP INSULATION, TO <br />PERMIT FLEXIBLE DUCT <br />CONNECTION AND OBD <br />INSTALLATION <br />ATTACH COLLAR TO DIFFUSER <br />NECK W/ SCREWS 4" O/C SEAL <br />JOINT W/ DUCT SEALER AND TAPE. <br />TO DIFFUSER <br />SPIN-IN FITING WITH <br />EXTRACTOR AND <br />QUADRANT DAMPER <br />MAKE TAP AT SIDE OR <br />BOTTOM AS SHOWN ON <br />PLANS <br />SEAL JOINT WITH DUCT <br />SEALER & TAPE <br />DIFFUSER <br />REF: $M15709B <br />SPECIFIED <br />DUCT SIZE <br />SCALE:N.T.S. <br />ROOF DUCT PENETRATION DETAIL <br />(B) <br />STANDARD DUCT <br />CONSTRUCTION SEAMS <br />WATERTIGHT SEAL <br />FLASHING <br />ROOFING <br />DUCT INSULATION <br />METAL FLASHING <br />SHOULD EXTEND 4" MIN. <br />BELOW TOP OF CURB <br />FOR DETAIL B <br />REF: $M15720C <br />REF: $M15810A SCALE:N.T.S. <br />DAMPER CONTROL SYSTEM <br />BOWDEN CABLE REMOTE <br />NOTES : <br />1. COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT PRIOR TO <br />INSTALLATION. <br />2. THE 270-896 BOWDEN CABLE CONTROL SYSTEM IS DESIGNED TO BE IMBEDDED IN THE CEILING FLUSH WITH <br />THE FINISHED SURFACE. <br />3. CABLE SHALL CONSIST OF BOWDEN CABLE 0.054" STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN 1/16" <br />FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH. <br />4. LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE USED <br />TO CONVERT ROTARY MOTION INTO PUSH-PULL MOTION. <br />5. CONTROL SHAFT SHALL BE "D"-STYLE FLATTENED 1/4" DIAMETER WITH 265° ROTATION PROVIDING 1-1/2" <br />LINEAR TRAVEL CAPABILITY. <br />ROUND DAMPER <br />FLEXIBLE CASING <br />AND WIRE (50'-0" <br />MAXIMUM) <br />RIGID DUCTWORK <br />FLEXIBLE DUCTWORK <br />RACK & PINION <br />OPERATOR <br />MOUNTING BRACKET <br />SOCKET WRENCH <br />CEILING DIFFUSER <br />7/8" THREADED CAP, TAMPER <br />PROOF OPTIONAL <br />CONCEALED REGULATOR KIT <br />3 3/4" <br />3 3/4" <br />2 1/4 <br />3 3/8 <br />2 4" W ATERP RO O F DUCT <br />6"6" <br />A <br />B <br />1" AIR GAP <br />UNIT TYPE A B <br />DRAW THRU 2" PLUS X X <br />BLOW THRU 1" MIN 2X <br />WHERE "X" = STATIC PRESSURE IN PAN. <br />D1 D2 <br />D5 ELBOWS VANE CONSTRUCTION DETAILS <br />N.T.S. <br />D8 <br />TYPICAL AHU CONDENSATE <br />DRAIN CONNECTION DETAIL <br />N.T.S. <br />D7 <br />D9 D10 D11 <br />D16 <br />SCALE:N.T.S. <br />DUCT SUPPORT DETAIL <br />SCALE:N.T.S. <br />OUTSIDE AIR INTAKE DETAIL <br />SCALE:N.T.S. <br />BOWDEN CABLE <br />MANUAL VOLUME DAMPER REMOTE CENTER <br />SCALE:N.T.S. <br />PENETRATION DETAIL <br />ROOF DUCT (INSULATED) <br />SCALE:N.T.S. <br />CEILING DIFFUSER INSTALLATION DETAIL <br />SCALE:N.T.S. <br />PENETRATION DETAIL <br />ROOF DUCT (UNINSULATED) <br />SCALE:N.T.S. <br />EXHAUST FAN ROOF MOUNTING DETAIL <br />UPBLAST <br />SERIES FANSDOWNBLAST <br />SERIES FANS <br /> CONCRETE DECK ANCHORING <br />3/8" S.S. HILTI KWIK BOLT 3 <br />EXPANSION ANCHORS <br />MIN. 2.50" ENGAGEMENT <br />SEE TABLE FOR QTY. <br />(5" MIN. EDGE DISTANCE) <br />2000 MIN. PSI <br />CONCRETE <br />ROOF CURB <br />NOA RATED ROOF CURB, <br />18 GA. MIN.; 24" TALL MAX. <br />WELDED CONSTRUCTION <br />CURB CORNER <br />ANCHOR DETAIL <br />CURB TO DECK MOUNTING <br />GREENHECK UNIT SIZE <br />CONCRETE ANCHORING <br />NO. OF FASTENERS PER <br />SIDE <br />STEEL DECK ANCHORING <br />NO. OF FASTENERS PER <br />SIDE <br />CUE / CUBE < 161 <br />G / GB < 141 2 2 <br />CUE / CUBE > 161 <br />G / GB > 141 3 3 <br />FASTENERS NEED TO BE LOCATED ON 2 OPPOSITE ENDS OF FAN CURB. <br />FAN TO CURB MOUNTING <br />GREENHECK UNIT SIZE FASTENERS PER SIDE <br />CUE-060 THRU HP-161/HP, CUBE-098 THRU HP-161/HP/XP <br />S-CUBE-141 THRU HP-161/HP, G-060 THRU 141, GB-071 THRU HP-161/HP 3 <br />CUE-180/HP-200, CUBE-180 THRU HP-240/HP/XP, <br />S-CUBE-200 THRU 240, G-060 THRU 150, GB-180 THRU HP-240/HP 5 <br />CUBE-300/HP/XP, S-CUBE-300, GB-260-300/HP 9 <br />FASTENERS ON EACH SIDE OF THE FAN ARE TO BE INSTALLED WITH ONE FASTENER 4 INCHES FROM EACH EDGE <br />AND ONE FASTENER CENTERED. THE FASTENERS ARE TO BE EQUALLY SPACED.5/16 INCH SELF-DRILLING SCREWS. <br />FRONT VIEW <br />TYPICAL ELBOW <br />SIDE VIEW <br />2-1/4" R <br />45° <br />2-1/4" <br />4-1/2" R <br />45° <br />2-1/4" <br />3-1/4" <br />2" R <br />DEPTH (D) <br />WIDTH (W) <br />45°45° <br />1" R <br />1-1/8" 1-1/8" <br />2-1/8" <br />NOTES <br />1. ALL SQUARE OR RECTANGULAR ELBOWS SHALL HAVE ONE OF THE <br />TWO TYPES OF TURNING VANES SHOWN ABOVE. SINGLE VANE <br />ELBOWS WILL NOT BE PERMITTED. <br />2. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS <br />RECOMMENDED BY SMACNA. <br />3. ALL SQUARE OR RECTANGULAR ELBOWS SHOWN ON PLANS FOR <br />EXHAUST OR RETURN DUCT MAY BE MADE RADIUS ELBOWS <br />PROVIDED SPACE PERMITS RADIUS INSTALLATION. <br />4. ALL SQUARE OR RECTANGULAR ELBOWS SHOWN ON PLANS FOR <br />SUPPLY DUCT MAY BE MADE RADIUS ELBOWS PROVIDED SPACE <br />PERMITS RADIUS INSTAL- LATION AND/OR THERE ISN'T AN OUTLET <br />OR TAKE-OFF WITHIN 5D ON THE DOWNSTREAM SIDE OF THE <br />ELBOW. <br />SMALL DOUBLE VANE ELBOW USE FOR ELBOWS BELOW <br />36" IN WIDTH AND ANY DEPTH <br />LARGE DOUBLE VANE ELBOW USE FOR ELBOWS 36" 0R <br />WIDER AND ANY DEPTH <br />UNION <br />DRAIN PAN <br />AHU <br />THREADED CAP WITH <br />PERFORATION ON TOP <br />DRAIN LINE SHALL BE AT LEAST THE <br />SAME SIZE AS THE NIPPLE ON THE <br />DRAIN PAN <br />PITCH DOWN <br />TOWARD DRAIN <br />NOTES : <br />1. FIRE RATED PACKING SHALL BE U.L. SYSTEM C-AJ-1015. <br />2. SLOPE PIPE @ 1/4" PER FOOT. <br />3. PROVIDE SHIELDING OVER CONDENSATE PIPING WHERE SUBJECT TO <br />DAMAGE. <br />4. SECURE NEW CONDENSATE DRAIN PIPING TO FLOOR WITH COPPER <br />BRACKETS OR CLAMPS (USE NON-FERROUS FASTENERS). <br />5. CONDENSATE LINE SHALL BE INSULATED WITH 1" ARMFLEX. PROVIDE <br />PROTECTIVE ALUMINUM JACKETING TO PROTECT AGAINST DAMAGE. <br />CLEAN-OUT (TYP.) <br />CONCRETE ANCHORS <br />CONCRETE ANCHORS <br />(TYPICAL) <br />STRAP SPACED AS PER <br />SMACNA STANDARDS, <br />SEE SPECIFICATIONS <br />SECTION 15815 <br />WASHER MAY BE OMITTED WITH <br />100 LBS. (45 KG) MAX LOAD ON <br />22 GA. (0.85 mm) STRAP WHEN <br />FOLDED <br />DO NOT BEND STRAP AT <br />90° BEND UNDER LOAD EXPANSION <br />SHIELDS <br />EXPANSION NAIL <br />WASHER <br />PROVIDE GASKET AT <br />CONNECTION BETWEEN <br />DUCTWORK AND LOUVER <br />OUTSIDE AIR LOUVER W/ <br />VERTICAL BLADES SEE <br />ARCH. DWGS. FOR <br />DETAILS <br />WALL <br />BIRDSCREEN <br />DUCT INSULATION, SEE <br />SPECIFICATIONS FOR <br />DETAILS <br />INSULATION <br />D4D3 <br />D6 <br />TO CONTROL <br />DAMPER <br />MODEL <br />270-896C <br />PLASTIC CAP <br />"U" BRACKET <br />SUPPORT <br />STEEL PIPE <br />CEILING7/8"∅ CAP <br />WEATHERPROOF DUCTWORK, <br />SEE MECH SPECS FOR <br />INSULATION REQUIREMENTS <br />CURB TOP FLASHING WITH DRIP <br />EDGE & WEATHERPROOF COLLAR <br />BY G.C. <br />12" ALUMINUM COUNTER - <br />FLASHING SKIRT BY MECH <br />CONTRACTOR, SEALED TO <br />DUCT "S" SLIP BY MECH <br />CONTRACTOR <br />CURB FURNISHED BY MECH <br />CONTRACTOR, INSTALLED, <br />FLASHED & SEALED BY G.C. <br />MECH CONTRACTOR TO PACK <br />VOIDS BETWEEN DUCT & <br />STRUCTURAL OPENING (TYP), SEE <br />SPECIFICATION <br />SILICONE CAULKING <br />BY MECH <br />CONTRACTOR (TYP) <br />2" LINER BEGINS <br />1" LINER ENDS <br />AIR FLOW <br />EXTRACTOR <br />ROUND SHEET METAL <br />COLLAR <br />SECURE FLEX. WITH METAL <br />BANDS <br />4" TO 6" HIGH ROUND <br />METAL DUCT COLLAR WITH <br />11/2 LBS. 1" THICK DUCT <br />WRAP INSULATION <br />SEAL INSULATION TO <br />DUCT AND CEILING WITH <br />VAPOR BARRIER TAPE <br />SUPPLY <br />DUCT <br />INSULATED FLEXIBLE <br />ROUND, SEE <br />SPECIFICATIONS <br />OPPOSSED BLADE <br />DAMPER, SEE <br />SPECIFICATIONS <br />CEILING <br />DIFFUSER GRID BAR <br />WEATHERPROOF DUCTWORK, <br />SEE MECH SPECS FOR <br />INSULATION REQUIREMENTS <br />CURB TOP FLASHING WITH DRIP <br />EDGE & WEATHERPROOF COLLAR <br />BY G.C. <br />12" ALUMINUM COUNTER - <br />FLASHING SKIRT BY MECH <br />CONTRACTOR, SEALED TO <br />DUCT "S" SLIP BY MECH <br />CONTRACTOR <br />CURB FURNISHED BY MECH <br />CONTRACTOR, INSTALLED, <br />FLASHED & SEALED BY G.C. <br />MECH CONTRACTOR TO PACK <br />VOIDS BETWEEN DUCT & <br />STRUCTURAL OPENING (TYP), SEE <br />SPECIFICATION <br />SILICONE CAULKING <br />BY MECH <br />CONTRACTOR (TYP) <br />D12 D13 D14 D15 <br />REF: $M15618 <br />REF: $M15737REF: $M15736A <br />REF: $M15810REF: $M15721B REF: $M15726REF: $M15721A <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOUDLER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD: #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT, UNIT 15 <br />DORAL, FL 33172 <br />t. 305.418.9177 f 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELECTRICAL + PLUMBING <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />FIRM CERTIFICATION C.A. #26243 <br />IGOR F. GONZALEZ P.E. #56098 <br />1 2 /4 /2 0 1 8 6 :1 4 :0 1 P M <br />D :\U s e r s \K a r i n \D o c u m e n t s \C 0 2 0 3 2 1 1 8 -M E C H _R 1 8 _k a r i n c @ e s i c o n s u l t .c o m .r v t <br />M40-01 <br />MECHANICAL DETAILS <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd, <br />Suite 1300, <br />Coral Gables, FL 3313 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />MARK ISSUE DATE <br />PERMIT SET 12.06.2018