SCALE: <br />40" MIN. <br />18" MIN. <br />SCALE:N.T.S. <br />TYPICAL HOOD EXHAUST FAN DETAIL <br />EXHAUST FAN <br />HINGED VENTED <br />ROOF CURB <br />GALVANIZED STEEL <br />CURB W/ FLASHING & <br />COUNTERFLASHING <br />ROOF SLAB EXHAUST DUCT, SEE <br />PLANS FOR SIZE <br />FINISHED ROOF <br />NOTE : COMPLETE FAN ASSEMBLY INCLUDING <br />ROOF CURB SHALL BE NOA RATED. <br />REF: $M15615 SCALE: <br />SCALE: <br />SCALE:SCALE:SCALE:N.T.S. <br />TYPICAL HORIZONTAL <br />AIR SPLITTER DAMPER DETAIL <br />D <br />NOTCH DIRECTION OF <br />BLADE ON BOTH ENDS OF <br />SQUARE BAR <br />5/16 " GALVANIZED <br />STEEL ROD <br />SET SCREW <br />SPACER ATTACHED TO <br />METAL SLEEVE <br />AIR FLOW <br />18" GAGE GALV. <br />SHEET STEEL <br />DAMPER BLADE: FULL <br />HEIGHT OF MAIN <br />DUCT. <br />DOUBLE BEND <br />LEADING EDGE OF <br />DAMPER BLADE. <br />2 x "D" IF <br />POSSIBLE <br />TAPED JOINT <br />REF: $M15706 <br />40" MIN. <br />18" <br />6" MIN. 6" MIN. <br />26" <br />7'-0" <br />6" MIN <br />6" <br />2 1 " T Y P . <br />F O R 2 4 " W I D E W R A P1 1 /2 "1 0 1 /2 " <br />1 1 /2 " <br />1 1/2" <br />3" <br />1 1 /2 " <br />1 1/2" <br />3" <br />1 1/2" <br />3" <br />1 1/2" <br />3" <br />1 1/2" <br />3" <br />1 1/2" <br />1 1 /2 " <br />MAX. <br />M A X . <br />8" <br />1 0 1 /2 " <br />21" TYP. <br />21" TYP. <br />EBTRON <br />GOLD SERIES <br />** <br />SCALE:N.T.S. <br />TRAPEZE TYPE PIPE HANGER <br />SCALE:N.T.S. <br />OVERHEAD PIPE SUPPORT <br />SCALE:N.T.S. <br />TYPICAL WALL/FLOOR <br /> PIPE PENETRATION DETAIL D4 <br />FIRE RATED BLANKET INSTALLATION <br />DETAIL FOR DUCT EXITING ROOF <br />N.T.S. <br />D5 D6 <br />COMMERCIAL KITCHEN GREASE DUCT <br />ACCESS DOOR SYSTEM <br />N.T.S. <br />FIREMASTER 1-1/2" FASTWRAP+ <br />SCALE:N.T.S. <br />KITCHEN EXHAUST HOOD AND DUCT SYSTEM MOUNTING DETAILS <br />FOR HOOD MOUNTED ADJACENT TO NON-COMBUSTIBLE WALLSD5 <br />ALTERNATE <br />PINNING TECHNIQUE <br />D7 <br />FIREMASTER 1 1/2" FASTWRAP+ COMMERCIAL KITCHEN GREASE DUCT <br />2 HOUR SHAFT ALTERNATIVE - ZERO CLEARANCE TO COMBUSTIBLES <br />N.T.S. <br />GREASE DUCTS ONLY: <br />SIZES >24"X48" IN CROSS SECTION <br />PINNING TECHNIQUE REQUIRED. <br />OVERLAP WRAP OPTION <br />CROSS SECTION VIEW <br />BUTT JOINT OPTION <br />CROSS SECTION VIEW <br />CHECKERBOARD WRAP OPTION <br />CROSS SECTION VIEW <br />D8 <br />TYPICAL CURB DETAIL <br />AT CONCRETE DECK <br />N.T.S.D9 <br />EBTRON GOLD SERIES <br />AFMS ON RECTANGULAR DUCT DETAIL <br />N.T.S.D10 <br />SECTION A-A A <br />A <br />HANGER ROD, FASTEN <br />TO STRUCTURE <br />COMBINATION RUBBER-IN <br />SHEAR & SPRING VIBRATION <br />ISOLATORS WHERE <br />SPECIFIED ONLY <br />RIGID INSULATION <br />PIPE (TYP.) <br />U-BOLT <br />(TYP) <br />PIPE TO 4" USED CHANNEL <br />1-5/8"x2-7/16"x12GA. PIPE <br />FROM 5 TO UP USED. <br />STEEL INSULATION SHIELD <br />ADJUSTABLE TRAPEZE <br />COMBINATION RUBBER IN <br />SHEAR & SPRING TYPE <br />VIBRATION ISOLATORS WHERE <br />SPECIFIED ONLY <br />CLEVIS TYPE HANGER <br />STEEL INSULATION <br />SHIELD <br />HANGER ROD FASTEN TO <br />STRUCTURE <br />RIGID INSULATION <br />PIPE <br />NOTE: ALL SUPPORT'S COMPONENTS <br />SHALL BE HOT-DIPPED GALVANIZED <br />INSULATED METAL PIPE THROUGH 2-HR. GYPSUM WALL <br />PROTOTYPE: HILTI <br />U.L. SYSTEM No. WL5029 <br />F RATING = 2-HR <br />T RATING = 1-HR <br />MINIMUM 1/2" CROWN <br />HILTI FS-ONE <br />INTUMESCENT <br />FIRESTOP SEALANT. <br />MAX. 2" THICK <br />FIBERGLASS INSULATION. <br />W/ AN ALL SERVICE <br />JACKET <br />2-HR. FIRE RATED GYPSUM WALL <br />ASSEMBLY <br />NOTE: <br />1. MAX. DIA. OF OPENING IS 15" <br />2. ANNULAR SPACE REQUIRED MIN. 0" TO MAX. 1 7/8" <br />10" DIA. (OR SMALLER) STEEL PIPE <br />(SCHEDULE 40 OR HEAVIER), COPPER <br />PIPE, EMT OR STEEL CONDUIT <br />FIRESTOP SEALANT <br />MIN. 1-1/4" DEPTH <br />HILTI FS-ONE <br />INTUMESCENT <br />D1 D2 D3 <br />4 <br />6 <br />3 <br />2 <br />1 <br />5 <br />FIREMASTER DUCT SYSTEM <br />DUCT <br />ROOF <br />ROOF OVER-FLASHING <br />VENT FLASHING <br />ONEL LAYER FIREMASTER FASTWRAP+, 2" THICK <br />FIREMASTER FIRESTOP SYSTEM ONLY NEEDED FOR RATED ROOFS <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />1 <br />3 <br />4 <br />8 <br />9 <br />10 <br />7 <br />6 <br />5 <br />2 OMEGA POINT LABORATORIES DESIGN NO. GD 544 F <br />AND GD 562 F, UL ASSEMBLY NO. G-14 <br />DOOR HOLE <br />1/4" DIA. ALL THREAD RODS <br />ACCESS COVER - 16 GAUGE <br />INSULATION PINS - WELDED <br />ONE LAYER FIREMASTER FASTWRAP+, 1 1/2" THICK <br />ONE LAYER FIREMASTER FASTWRAP+ 1" OVERLAP <br />SPEED CLIPS <br />ALUMINUM TAPE AT EDGES <br />SPOOL PIECES FOR THREADED RODS <br />1/4" DIA. WING NUTS <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />6"MIN. <br />COOKING <br />EQUIPMENT <br />HOOD FRONT VIEW <br />(TYP.) <br />18"MIN <br />HOOD <br />1" MINERAL WOOL <br />INSULATION AND 22 GA. <br />STAINLESS STEEL PLATE. <br />16 GA. EXT. WELDED LIQUID TIGHT <br />EXHAUST DUCT.CEILING STRUCTURE <br />AND ROOFING ARE NON <br />COMBUSTIBLE <br />PROVIDE W/ HINGED <br />VENTED ROOF CURB <br />NOTE : <br />NEGATIVE PRESSURE IN <br />COOKING AREA SHALL NOT <br />EXCEED .02" H2O <br />FINISHED FLOOR <br />COOKING <br />EQUIPMENT <br />EXTEND MINERAL WOOD <br />AND STEEL PLATE FULL <br />HEIGHT OF WALL WITHIN 18" <br />OF EXHAUST DUCT. <br />MAKE-UP AIR DUCT FROM <br />SUPPLY FAN <br />FIRE ACTIVATED DAMPER IN <br />ACCORDANCE W/ NFPA <br />96-2-3.1.2 <br />MAKE-UP AIR PLENUM <br />FINISHED FLOOR <br />LOCATE EXHAUST <br />FAN MIN. 10'-0" <br />AWAY FROM <br />MAKE-UP AIR FAN <br />1" MINERAL WOOL <br />INSULATION <br />HOOD SIDE VIEW <br />EXHAUST FAN <br />HOOD (SEE KITCHEN <br />CONSULTANT DWG.) <br />NON-COMBUSTIBLE ROOF <br />CURB WITHOUT WOOD <br />NAILER. <br />3 <br />4 <br />2 <br />1 <br />7 <br />1 <br />2 3 <br />1 <br />2 <br />1 <br />3 <br />2 <br />5 <br />6 <br />Omega Point Laboratories Design Nos. GD 544F, GD 562F <br />UL Assembly Nos. G-14, V-19 <br />ONE LAYER FIREMASTER FASTWRAP+, 1 1/2" THICK <br />STEEL BANDING 1/2" WIDE MIN. <br />3" MIN. LONGITUDINAL OVERLAP <br />3" MIN. PERIMETER OVERLAP <br />6" WIDE FIREMASTER FASTWRAP+ COLLAR (FOR BUTT JOINT <br />OPTION) <br />FIRMLY BUTTED JOINT (FOR BUTT JOINT OPTION) <br />10 OR 12 GAUGE STEEL INSULATION PIN WITH 1 1/2 " x 1 1/2 " <br />OR 11/2" DIA. GALVANIZED SPEED CLIPS <br />(FOR ALTERNATE PINNING) <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />ROOF CURB BY UNIT <br />MANUFACTURER <br />2 1/4 " LONG TAPCONS <br />AT 12" O.C. EACH SIDE <br />AND AT CORNERS <br />SENSOR CABLE <br />FACTORY SUPPLIED <br />TYP. (1 TO 4) <br />NOTES: <br />1. TRANSMITTER SHALL BE EQUIPPED WITH AN ANALOG TEMPERATURE OUTPUT THAT CAN BE CONFIGURED AS <br />AN ALARM OUTPUT. ALARM CAN BE SET AS ACTIVE HIGH, ACTIVE LOW OR SET-POINT. <br />2. CONNECT OUTPUT SIGNAL CABLE. CABLE DRAINS TO EARTH GROUND AT ONE END ONLY. <br />3. ON MULTIPLE TRANSMITTER INSTALLATIONS WITH A COMMON 24 VAC SOURCE, WIRE 24 VAC POWER TO <br />THE SAME TERMINALS ON ALL TRANSMITTERS (E.G. L1 TO L1, L2 TO L2). <br />4. COORDINATE WITH CONTROLS CONTRACTOR IN ORDER INTERFACE & MONITOR THRU EXISTING BMS. <br />** REFER TO MANUFACTURER'S INSTALLATION MANUAL FOR INSTALLATION REQUIREMENT, SUCH STRAIGHT <br />RUNS, ETC. FOR PROPER PERFORMANCE. <br />24 VAC <br />2 CONDUCTOR <br />ANALOG BAS <br />CONTROL INTERFACE <br />RS-485 <br />CONTROL <br />INTERFACE <br />CUT OUT SLAB <br />WHERE REQUIRED <br />EXHAUST FAN / ROOF EQUIPMENT <br />RUBBER GASKET <br />EXTEND ROOFING UP AND OVER THE <br />TOP OF THE ROOF CURB <br />ROOF INSULATION AS REQUIRED <br />EXISTING CONCRETE DECK <br />PATCH AND REPAIR <br />ROOFING AS REQUIRED <br />INSTALLATION INSTRUCTION NOTES : <br />1.MEASURE AND CUT PIECES OF FIREMASTER FASTWRAP+ ALLOWING FOR 3" OVERLAPS AROUND THE CIRCUMFERENCE OF THE DUCT AND DOWN THE LENGTH OF THE DUCT. <br />2. ALL CUT EDGES TO BE SEALED WITH ALUMINUM TAPE. <br />3.FINAL FASTENING WITH MINIMUM WIDE STAINLESS STEEL OR CARBON STEEL BANDING (0.015" MINIMUM THICKNESS) SECURED WITH BANDING WING SEALS. <br />4. BANDING TO BE PLACED AN 1-1/2 INCHES FROM THE EDGE ON THE PERIMETER OVERLAPS WITH A MINIMUM 10-1/2 INCH S PACING DOWN THE LENGTH OF THE DUCT. <br />5. IN ADDITION TO BANDING ON DUCTS 24" AND WIDER, THE BOTTOM AND AT LEAST ONE VERTICAL SIDE OF FASTWRAP+ TO BE SECURED WITH WELDED 12 GAUGE STEEL INSULATION <br />PINS, LOCKED INTO PLACE WITH 1-1/2 INCHES DIAMETER ROUND OR SQUARE, GALVANIZED SPEED CLIPS OR CUP HEAD PINS. <br />6. PINS THAT EXTEND BEYOND THE BLANKET SHALL BE TRIMMED AND/OR TURNED DOWN FOR SAFETY. <br />7.FIREMASTER CAN BE INSTALLED WITH A ZERO CLEARANCE AT THE OVERLAPS OR IN THE FIELD BETWEEN THE OVERLAPS. <br />8.FOR COMPLETE DETAILS ON THE INSTALLATION OF FIREMASTER FASTWRAP+, PLEASE REFER TO THE PRODUCT'S DATA/SUBMITTAL SHEET. <br />REF: $M15206AREF: $M15207BREF: $M15409D <br />REF: $M15614 <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOUDLER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD: #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT, UNIT 15 <br />DORAL, FL 33172 <br />t. 305.418.9177 f 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELECTRICAL + PLUMBING <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />FIRM CERTIFICATION C.A. #26243 <br />IGOR F. GONZALEZ P.E. #56098 <br />1 2 /4 /2 0 1 8 6 :1 4 :0 2 P M <br />D :\U s e r s \K a r i n \D o c u m e n t s \C 0 2 0 3 2 1 1 8 -M E C H _R 1 8 _k a r i n c @ e s i c o n s u l t .c o m .r v t <br />M40-02 <br />MECHANICAL DETAILS <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd, <br />Suite 1300, <br />Coral Gables, FL 3313 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />MARK ISSUE DATE <br />PERMIT SET 12.06.2018
The URL can be used to link to this page
Your browser does not support the video tag.