Laserfiche WebLink
UR <br />E <br />F <br />U <br />R <br />E <br />F <br />DN <br />S <br />F G H I <br />J <br />K L M <br />1 <br />1.2 <br />2 <br />2.2 <br />3 <br />4 <br />RECEPTION <br />100 <br />CONFERENCE <br />ROOM <br />104 <br />CORRIDOR <br />121 <br />? <br />? <br />BANQUET HALL <br />STORAGE <br />116 <br />CLASSROOM <br />111 <br />CATERING <br />KITCHEN <br />112 <br />CLASSROOM <br />109 <br />FITNESS CENTER <br />108 <br />BREAKROOM <br />103 <br />BANQUET HALL/ <br />MULTIPURPOSE <br />117 <br />LOUNGE <br />101 <br />? <br />? <br />STORAGE <br />122 ELEC. <br />118 <br />AV. <br />119 <br />? <br />? <br />MEETING ROOM <br />105 <br />TELEPHONE <br />ROOM <br />106 <br />WORKSTATIONS <br />107 <br />LOUNGE <br />128 <br />GAME LOUNGE <br />102F <br />SHELVING <br />102E <br />PANTRY <br />102B BANQUETTE <br />102D <br />LOUNGE <br />102C <br />LOUNGE <br />102A <br />JANITOR <br />114 <br />TRASH <br />113 <br />STOR. <br />120 <br />WOMENS <br />126 <br />MENS <br />127 <br />ELECTRICAL <br />123 <br />? <br />? <br />WC-2 L-1 <br />WC-1 WC-1 <br />L-2 L-2 <br />WC-1WC-1 WC-1 WC-1 <br />L-1 <br />WC-2 <br />L-1 <br />EXIST <br />4" AD <br />EXIST <br />4" AD <br />EXIST 6" <br />RWL UP <br />(8,200 SQ FT) <br />EXIST 6" <br />RWL UP <br />(3,500 SQ FT) <br />EXIST 6" <br />RWL UP <br />(3,700 SQ FT) <br />EXIST 6" RWL EXIST 6" RWL <br />EX <br />I <br />S <br />T <br /> <br />6 <br />" <br /> <br />R <br />W <br />L <br />EXIST 6" RWL <br />EXIST 4" RWL <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />R <br />W <br />L <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />R <br />W <br />L <br />EXIST 4" RWLEXIST 4" RWL <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />R <br />W <br />L <br />EXIST 6" <br />RWL UP <br />(3,500 SQ FT) <br />EXIST 6" RWLEXIST 6" RWL6" R WL <br />EXIST 4" RWLEXIST 4" RWL <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />R <br />W <br />L <br />EXIST <br />4" AD <br />EXIST <br />4" AD <br />EXIST <br />4" AD <br />EXIST <br />4" AD <br />EXIST <br />4" AD <br />EXIST 4" RWL EXIST 4" RWL EXIST 4" RWL EXIST 4" RWL <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />SK-1 <br />SK-1 <br />4" S <br />CONNECT <br />NEW 4" SAN <br />TO EXIST 4" <br />SAN <br />CONNECT <br />NEW 2" SAN <br />TO EXIST 4" <br />SAN <br />2" <br /> <br />S2" S 2" S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />G <br />W <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />G <br />W <br />EXIST 4" SAN <br />CAPPED FOR <br />FUTURE TOILETS <br />WC-2WC-1 <br />3"FD-A <br />K-30 <br />K-1 <br />K-36 <br />K-38 <br />K-41 <br />K-43 <br />K-45 <br />K-44 <br />K-51K-57 <br />K-58 <br />UR-1 UR-1 <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />3"FD-A <br />4"FS-1 <br />3"FD-A <br />3"FD-A 3"FD-A <br />3"FD-A <br />4"FS-1 <br />4"FS-1 <br />4" S <br />4" <br /> <br />S <br />4" <br /> <br />S <br />4" S <br />CONNECT <br />NEW 4" SAN <br />TO EXIST 4" <br />SAN <br />3" <br /> <br />S <br />3" <br /> <br />S <br />FCO <br />4" S <br />4" <br /> <br />G <br />W <br />4" GW <br />4" <br /> <br />G <br />W 3" GW <br />4" <br /> <br />G <br />W <br />4"FS-1 <br />4" GW <br />3" <br /> <br />G <br />W <br />3" <br /> <br />G <br />W <br />4" GW <br />3" GW <br />4" GW <br />3" <br /> <br />G <br />W <br />4" <br /> <br />G <br />W <br />4" <br /> <br />G <br />W <br />CONNECT NEW <br />4" SAN GREASE <br />WASTE TO <br />EXIST 4" SAN <br />GREASE WASTE <br />4" GW <br />4" <br /> <br />G <br />W <br />4" <br /> <br />G <br />W <br />FCO <br />4" V 4" V <br />4" <br /> <br />V <br />4" <br /> <br />V <br />2" V 2" V2" V 2" V <br />2" <br /> <br />V <br />EWC-1 <br />3"FD-A 3" S 3"FD-A3" S <br />EXIST 4" S EXIST 4" S <br />EXIST 3" S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EXIST 4" S <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />S <br />EXIST 6" RWL <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />G <br />W2" R WL <br />2" <br /> <br />V <br />EX <br />I <br />S <br />T <br /> <br />2 <br />" <br /> <br />V <br />EXIST 4" V <br />2" <br /> <br />S <br />4" V <br />2" V <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />V <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />V <br />2" V <br />K-30 <br />EXIST <br />4" V UP <br />4" VTR <br />CONNECT <br />NEW 4" V TO <br />EXIST 4" V2" <br /> <br />V <br />2" <br /> <br />V <br />4" V <br />CONNECT <br />NEW 4" V TO <br />EXIST 4" V <br />2" <br /> <br />S <br />2" V <br />WB-1 <br />CONNECT <br />NEW 2" V TO <br />EXIST 2" V <br />CONNECT <br />NEW 2" SAN TO <br />EXIST 3" SAN <br />2" RWL CONNECT <br />TO PLANTER <br />DRAIN. REFER TO <br />ARCH DETAILS <br />CONNECT (2) <br />NEW 2" V TO <br />EXIST 4" V <br />CONNECT <br />NEW 2" V TO <br />EXIST 4" V <br />EX <br />I <br />S <br />T <br /> <br />4 <br />" <br /> <br />V <br />2" V <br />2" S <br />CONNECT <br />NEW 2" VENT <br />TO EXIST 2" <br />VENT <br />K-60 <br />K-42 <br />K-34 <br />K-33 <br />K-23 <br />K-15 <br />K-10 <br />SK-1CONNECT <br />NEW 3" SAN TO <br />EXIST 4" SAN <br />REMOVE EXISTING <br />FLOOR DRAIN AND CAP <br />ASSOCIATED PIPE <br />BELOW SLAB <br />3" <br /> <br />S <br />3"FD-A <br />K-12 <br />K-8 <br />3"FD-A <br />3" S <br />KIOSK <br />130 <br />KIOSK OFFICE <br />131 <br />LAUNDRY <br />135 <br />2" <br /> <br />C <br />D <br />2" <br /> <br />C <br />D <br />3" CD <br />NEW 2" CONDENSATE DRAINAGE <br />PIPE ABOVE CEILING SHALL DROP <br />INTO EXISTING CONDENSATE <br />WASTE STANDPIPE HUB DRAIN. <br />NEW 2" CONDENSATE DRAINAGE <br />PIPE ABOVE CEILING TO RECEIVE <br />HVAC UNIT PUMPED CONDENSATE. <br />REFER TO MECHANICAL DRAWINGS <br />FOR CONTINUATION.3" C D 3"FD-A <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :3 2 :3 1 P M <br />C :\_R e v i t \P F P - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />P10-01 <br />LEVEL 01 -DRAINAGE <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />1/8" = 1'-0"1 T. O GROUND LEVEL - Drainage <br />NO. ISSUE DATE <br />PERMIT SET 12.06.2018