IN-LINE CIRCULATING PUMP <br />ASSEMBLY <br />HOT WATER CIRCULATING <br />BALANCING VALVE ASSEMBLY <br />BELOW SLAB PIPE HANGER DETAIL <br />NTS <br />FROM <br />SYSTEM <br />TO RECIRC. <br />PUMP UNION <br />BALL VALVE <br />TIGHT SHUT-OFF BALANCING <br />VALVE <br />CHECK VALVE <br />NOTES: <br />1. INSURE PROPER ACCESS IS PROVIDED TO VALVE AND THAT VALVE CAN BE METERED. DO <br />NOT ORIENT TAPS DOWNWARD. <br />2. PROVIDE ACCESS PANEL IN HARD CEILING LOCATIONS. <br />3. PROVIDE TEE HANDLE WHERE LIMITED ACCESS. <br />NTSNTS <br />NOTES: <br />2. WHERE RE-CIRC. PIPING ON PUMP DISCHARGE IS LESS THAN 1-1/2", CONTRACTOR SHALL <br /> INSTALL SEPARATE CHECK VALVE, SHUT-OFF VALVE, AND BALANCE VALVE IN LIEU OF <br /> MULTI-PURPOSE VALVE. <br />3 1/2" DIAL 0-60" PSI <br />DISCHARGE GAUGE (TYP) <br />SHUT-OFF VALVE (TYP) <br />STRAINER <br />1/4" SHUTOFF COCK <br />IN-LINE PUMP <br />REDUCING TEE (TYP) <br />PIPING TO CW LINE TO WATER <br />HEATER INLET. PROVIDE CHECK <br />VALVE UPSTREAM OF CONNECTION <br />UNION TYPE CONNECTION (TYP) <br />MULTI-PURPOSE VALVE <br />(INSTALL IN HORIZONTAL <br />POSITION ONLY, SEE NOTE) <br />1. CONTRACTOR SHALL INSTALL AQUASTAT IN RETURN LINE FOR PUMP CONTROL <br />NTS <br />PIPE INSULATION SHIELD <br />SCHEDULE <br />WATER HEATER SCHEDULE <br />ELECTRIC WATER HEATER PIPING DIAGRAM2 ICE MACHINE - FLOOR MOUNTED <br />NTS3 PIPE INSULATION SHIELD / HANGER DETAIL <br />NTS <br />6 TRAPEZE PIPE HANGER <br />NTS <br />1 <br />PIPE CLAMP. PROVIDE <br />UNINSULATED COPPER LINES <br />METAL CHANNEL STRUT <br />AND LARGER. <br />INSULATION SHIELD ON 3" <br />INSULATED PIPE LINE WITH <br />HANGER ROD <br />OR NYLON INSULATOR <br />PIPE CLAMPS WITH ELASTOMER <br />45 <br />7 <br />VB <br />EXPANSION TANK <br />110° HWR <br />CW <br />B.V. <br />ELECTRIC WATER HEATER <br />FIN. FLOOR <br />AQUASTAT <br />CW <br />120° HW <br />CIRCUIT SETTER 110° HWR <br />CW SUPPLY <br />RECIRC. PUMP <br />120° HW <br />ONE HEATER / ONE TEMP <br />HCT36119 <br />100°F RISE <br />27 <br />KW <br />111208119 <br />GALS. <br />. <br />MODEL <br />LOCHINVAR <br />I.D. <br />EWH-1 <br />MANUFACTURER VOLT GPH @ <br />NTS <br />FLOOR DRAIN <br />w/TRAP PRIMER <br />4" HOUSEKEEPING PADFLOOR <br />FLOOR DRAINABOVE FD <br />MIN. 6" <br />DRAIN LINE <br />1/4" COPPER <br />FINISHED <br />ICE MACHINE <br />TUBING <br />BREAKER <br />PROVIDE VACUUM <br />UNION (TYP.) <br />PRESSURE GAUGE <br />(TYP.) <br />CHECK VALVE <br />BALL VALVE <br />1/2" CW <br />IN LINE FILTER <br />PROVIDE CLEAN SPACE <br />FOR FILTER <br />REPLACEMENT <br />PROVIDE MESH SCREEN <br />100 MESH/SQ.IN ON <br />DRAIN OUTLET <br />LENGTH <br />"L" <br />PIPE <br />DIAMETER <br />SHIELD <br />GAUGE <br />12"1/2" 18 <br />12"3/4" 18 <br />12"1" 18 <br />12"1 1/4" 18 <br />12"1 1/2" 18 <br />12"2" 18 <br />12"2 1/2" 18 <br />12"3" 18 <br />12"4" 12 <br />18"6" 16 <br />24"8" 14 <br />24"10" 14 <br />24"12" 14 <br />PIPING <br />INSULATION <br />HANGER ROD <br />HANGER <br />INSULATION SHIELD (STEEL), <br />CENTERED ON HANGER <br />"L" <br />(INSULATION SHIELD) <br />AMTROL ST-12-C <br />THREADED ROD LENGTH VARIES <br />ACCORDING TO PIPE ELEVATION <br />CONCRETE DRIVE FLOOR SLAB <br />NOTE: <br />SETTLEMENT. <br />ALL HANGER PARTS, RODS, AND <br />NUTS SHALL BE GALVANIZED AND <br />COATED WITH ASPHALTUM. THIS <br />DETAIL APPLIES TO ALL BELOW <br />SLAB PIPING. SPACING OF HANGERS <br />SHALL BE ONE EVERY 5'-0" PLUS <br />ADDITIONAL HANGERS AT FITTINGS <br />AS REQUIRED TO PREVENT FUTURE <br />"A" BAND TYPE HANGER <br />W/ DOUBLE NUTS, RODS <br />SHALL EXTEND DOWN TO <br />PIPE TO KEEP ASSEMBLY <br />BACKFILLING. <br />BELOW SLAB PIPING, <br />IN PLACE PRIOR TO <br />BURIED IN FILL. <br />BEND ROD OVER AFTER <br />BACKFILLING UP TO SLAB <br />ELEVATION & INSTALLING <br />REINFORCING. ROD SHALL <br />HAVE A MINIMUM OF 2" <br />OF CONCRETE BELOW IT. <br />BE 12". <br />MINIMUM LENGTH OF ROD <br />IN HORIZONTAL SHALL <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :3 2 :2 5 P M <br />C :\_R e v i t \P F P - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />P00-02 <br />PLUMBING DETAILS <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />NO. ISSUE DATE <br />PERMIT SET 12.06.2018
The URL can be used to link to this page
Your browser does not support the video tag.