Laserfiche WebLink
JJ <br />F1 <br />F1 <br />F1F1 <br />F1F1 <br />F1 <br />F1 <br />F1 <br />GFIGFI GFIGFI <br />TV <br />TV <br />TV <br />TV <br />GF <br />I <br />G <br />F <br />I <br />GF <br />I <br />G <br />F <br />I <br />GF <br />I <br />G <br />F <br />I J <br />J <br />J <br />J <br />J <br />J <br />TV <br />TV <br />J <br />JJJ <br />J <br />JJ <br />GF <br />I <br />G <br />F <br />I <br />GF <br />I <br />G <br />F <br />I <br />GFIGFI <br />GFIGFI <br />TV TV <br />J <br />TV <br />F1 <br />J <br />J <br />J <br />F1 <br />F1 <br />J <br />J J J <br />F1 <br />GFIGFI <br />J <br />J <br />J <br />J <br />J <br />J <br />J <br />J <br />F1 F1 <br />F1 F1 <br />F1 F1 <br />J <br />M <br />M <br />M <br />M <br />M <br />M <br />GENERAL POWER NOTES: <br />1. REFER TO ELECTRICAL LEGEND AND NOTES SHEET FOR DEFINITION OF ALL ELECTRICAL DEVICES. <br />2. REFER TO SPECIAL PURPOSE RECEPTACLE SCHEDULE ON ELECTRICAL LEGENDS AND NOTES SHEET FOR DEVICE AND BRANCH CIRCUIT INFORMATION. <br />3. REFER TO MOTOR WIRING SCHEDULE ON DRAWINGS FOR CONDUIT AND WIRE SIZE REQUIREMENTS TO EACH MOTOR, AND ALSO VERIFY WITH MANUFACTURER'S INFORMATION (TYPICAL) <br />4. REFER TO MECHANICAL DRAWINGS (HVAC, PLUMBING, AND FIRE PROTECTION) FOR EXACT LOCATION OF EQUIPMENT PRIOR TO SERVICE ROUGH-IN. <br />5. OUTLETS LOCATED WITHIN 6'-0" OF A SINK SHALL BE GFI TYPE (TYPICAL). <br />6. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL FLOOR AND WALL MOUNTED MEDICAL EQUIPMENT AND OTHER EQUIPMENT AND DEVICES BASED ON ARCHITECTURAL AND MEDICAL VENDOR <br />DRAWINGS PRIOR TO ROUGH-IN. <br />7. REFER TO COMMUNICATIONS DRAWINGS FOR ADDITIONAL SCOPE OF WORK TO BE COVERED BY THE ELECTRICAL CONTRACTOR (IT CABLE TRAYS, DATA/ PHONE OUTLETS, SECURITY, ETC). <br />8. GENERAL PURPOSE RECEPTACLES SHALL NOT EXCEED MORE THAN SIX PER CIRCUIT IN GENERAL AREAS. REFER ALSO TO ELECTRICAL SPECIFICATIONS FOR CIRCUITRY DESIGN CRITERIA. <br />9. HOME RUNS TO POWER PANELS SHALL HAVE A MINIMUM OF THREE (3) PHASE CONDUCTORS PLUS THREE (3) NEUTRALS AND GROUND CONDUCTORS IN EACH CONDUIT. ALL CIRCUITS SHALL HAVE INDIVIDUAL <br />NEUTRALS AND GROUND WIRES (NO EXCEPTION). <br />10. CONTRACTOR SHALL COORDINATE ANY POWER AND FIRE ALARM REQUIREMENT FOR ACCESS CONTROL AND SECURITY WITH THE LATEST TECH/IT,ARCHITECTURAL AND SECURITY DRAWINGS PRIOR TO <br />ROUGH-IN. REFER TO FIRE ALARM DRAWINGS FOR ADDITIONAL INFORMATION. <br />11. REFER TO ELECTRICAL RISER FOR SIZES AND QUANTITIES OF ALL CONDUITS. <br />F G H I J K L M <br />2 <br />2.2 <br />3 <br />4 <br />CCEDP <br />CCWDP <br />E50-01 <br />2 <br />E50-01 <br />3 <br />CCKP <br />USB <br />OHD OHD <br />COF <br />REF COF <br />USB <br />USB <br />REF <br />ICE <br />REFMIC <br />DW <br />USB USB PROJ <br />PROJ <br />PROJ <br />MP <br />MP <br />MP <br />HOOD-1 <br />PLUM <br />PLUMPLUMPLUM <br />PLUM <br />DRYDRY <br />EWC <br />RECEPTION <br />100 <br />CONFERENCE ROOM <br />104 <br />CORRIDOR <br />121 <br />BANQUET HALL STORAGE <br />116 <br />CLASSROOM <br />111 <br />CATERING KITCHEN <br />112 <br />CLASSROOM <br />109 <br />FITNESS CENTER <br />108 <br />BREAKROOM <br />103 <br />BANQUET HALL/ <br />MULTIPURPOSE <br />117 <br />LOUNGE <br />101 <br />STORAGE <br />122 <br />ELEC. <br />118 <br />AV. <br />119 <br />MECH <br />125 <br />MEETING ROOM <br />105 <br />TELEPHONE ROOM <br />106 <br />WORKSTATIONS <br />107 <br />LOUNGE <br />128 <br />GAME LOUNGE <br />102F <br />PANTRY <br />102B <br />BANQUETTE <br />102D <br />LOUNGE <br />102CLOUNGE <br />102A <br />JANITOR <br />114 <br />TRASH <br />113 <br />STOR. <br />120 <br />WOMENS <br />126 <br />MENS <br />127 <br />ELECTRICAL <br />123 <br />REFER TO KITCHEN PLANS AND ARCHITECTURAL <br />PLANS FOR EXACT LOCATIONS. (TYPICAL) <br />USB <br />FA NAC <br />FA NAC <br />TS <br />PROVIDE <br />CONNECTION TO <br />ACCESS <br />CONTROL <br />TURNSTILE. <br />CCWR-5 <br />USB <br />MP <br />PROJECTOR <br />DJ W/S <br />CCWR-7 <br />7 <br />USB <br />USB <br />CCWR-11 <br />11 <br />CCWR-9 <br />9 <br />9 <br />9 <br />FF <br />FF FF FF <br />LCPCCELCCERCCWR <br />CCWL LCP <br />CCER-9 <br />CCER-10 <br />CCER-3 <br />CCER-4 <br />CCER-1 <br />USB <br />USB <br />USB <br />USBUSB <br />CCWR-13 <br />13 <br />CCWR-15 <br />15 <br />CCWR-17 <br />171717 <br />CCWR-19 <br />19 <br />19 <br />USB <br />CCWR-21 <br />21 <br />21 <br />21 CCWR-23 <br />23 <br />23 <br />23 <br />CCWR-25 <br />CCWR-27 <br />CCWR-29CCWR-31 <br />CCWR-33 <br />33 <br />CCWR-35 <br />CCWR-3737 <br />37 <br />37 <br />CCWR-39 39 <br />39 39 <br />CCWR-41 <br />41 <br />41 <br />41 <br />CCWR-43 <br />4343 <br />43 <br />CCWR-45 <br />GFI <br />45 <br />CCWR-47 <br />47 <br />47 <br />47 <br />CCWR-49 <br />49 49 49 <br />CCWR-51 <br />51 <br />CCWR-53 <br />53 <br />53 <br />53 <br />CCWR-55 <br />CCWR-57 <br />57 <br />55 3 <br />TYP <br />3 <br />TYP <br />CCWR-59 <br />59 3 <br />CCWR-61 <br />4 <br />CCWR-63 <br />5 <br />CCER-5 <br />4 <br />4 <br />4 <br />45 45 <br />5 <br />CCWR-69CCWR-71 <br />71 <br />CCER-55 <br />CCER-17 <br />17 <br />17 <br />CCER-19 <br />CCER-21 <br />21 <br />21 <br />21 21 <br />E42-03 <br />3 <br />CCER-29 <br />29 <br />29 <br />29 <br />CCER-31 <br />31 <br />CCER-33 <br />33 <br />CCER-35 <br />35 35 <br />35 <br />SHELVING <br />102E <br />BANQUET HALL/ <br />MULTIPURPOSE <br />134 <br />FAMILY RESTROOM <br />110 <br />RECEPTION CORRIDOR <br />102 <br />CCER-37 <br />37 CCER-39 <br />39 <br />CCER-41 41 <br />CCWR-65CCWR-73 <br />CCWR-75 <br />75 <br />CCWR-77 <br />CCWR-79 <br />CCWR-81 <br />81 <br />CCWR-83 <br />CCER-45CCER-43 <br />CCEDP-8,10,12 <br />60A/3PH/208V/F <br />AHU-8 <br />SIGN <br />SIGN <br />CCWR-4 <br />4 <br />7 <br />7 <br />8 <br />SIGN <br />SIGN <br />SIGN <br />CCER-47 <br />47 <br />47 <br />6 <br />LIFT <br />LIFT <br />LIFT <br />CCER-49 <br />CCER-51 <br />CCER-53 <br />CCER-11 <br />CCER-13 <br />CCER-15 <br />55 <br />55 <br />59 <br />USB21 <br />USB <br />CCER-57,59 <br />30A/1PH/208V/F <br />3#8, 1#10G, 3/4"C <br />CCER-61 <br />61 <br />61 <br />63 63 <br />REFER TO STORAGE POWER PLAN <br />(E42-02) FOR WATER HEATER AND <br />PUMP CIRCUITING. <br />CCWR-12 <br />2 <br />22 <br />3 <br />2 <br />2 <br />EXISTING IT <br />ROOM <br />COORDINATE VFD LOCATION <br />WITH MECHANICAL DRAWINGS <br />FCU-1 <br />FCU-2 <br />CCER-65,67 <br />CCER-69 <br />CCER-69 <br />CONDENSATE <br />PUMP <br />CONDENSATE <br />PUMP <br />TIE TO <br />CONDENSATE <br />PUMP <br />CCER-69 <br />TIE TO <br />CCEL-5 <br />CCEL-9 <br />CCEL-7 <br />2 <br />2 <br />CCER-2 <br />CCER-63 <br />1 PROVIDE 4 QUAD RECEPTACLES, EACH WITH A DEDICATED 20A CIRCUIT. ALL CIRCUITS SHALL BE ON SAME PHASE. <br />POWER KEYNOTES: <br />2 PROVIDE PLUGLOAD CONTROLLER INTEGRATED WITH LIGHTING CONTROL SYSTEM TO CONTROL 50% OF <br />RECEPTACLES IN ALL ROOMS AS REQUIRED BY FBC EC/ASHRAE 90-1-2013. <br />3 IN FLOORBOX PROVIDE TWO DUPLEX RECEPTACLES, ONE ALWAYS ON, ONE CONTROLLED VIA <br />PLUGLOAD CONTROLLER. <br />4 NOT USED. <br />5 LUTRON SHADE / BLIND CONTROL PANEL <br />6 REFER TO KITCHEN POWER PLANS FOR ADDITIONAL REQUIREMENTS AND INFORMATION <br />7 COORDINATE CONTROL LOCATIONS AND DEVICES WITH ARCHITECT AND VENDOR <br />8 PROVIDE MYERS INVERTER 5.0 KVA WITH 208V/3PH 20A INPUT BREAKER AND SIX 20A 120V OUTPUT BREAKERS. <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :1 8 :4 4 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />E10-02 <br />LEVEL 01 -ELECTRICAL <br />POWER PLAN <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />1/8" = 1'-0"1 LEVEL 01 - Power - Community Center Area <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018