Laserfiche WebLink
GF <br />I <br />G <br />F <br />I <br />GFIGFI GFIGFI GFIGFI GFIGFI <br />FDFD <br />FD <br />K L M <br />1 <br />1.2 <br />30A/2P208V/F/NEMA 4XSS <br />CU-5A <br />PNL "A"-34,36 <br />PNL "A"-35 <br />CU-2 <br />PNL "A"-30,32 <br />3#8, 1#10 G IN 3/4"C <br />WP <br />F G H I J K L <br />2.2 <br />3 <br />4 <br />67 <br />CCWDP-1,3,5 <br />60A/3PH/208V/F/NEMA 4XSS <br />200A/3PH/208V/F/ <br />NEMA 4XSS <br />200A/3PH/ <br />208V/F/ <br />NEMA 4XSS <br />CCWDP-2,4,6 <br />100A/3PH/208V/F/NE <br />MA 4XSS60A/3PH/208V/F/NEMA 4XSS <br />1 <br />60A/3PH/208V/F/NEMA 4XSS <br />CCWDP-7,9,11 <br />60A/3PH/208V/F/NEMA 4XSS <br />CCWDP-8,10,12 <br />CCEDP-1,3,5 <br />60A/3PH/208V/F/NEMA <br />4XSS <br />CCEDP-7,9,11 <br />CCEDP-13,15 <br />30A/1PH/208V/F/NEMA <br />4XSS <br />RTU-5 <br />RTU-4 <br />EF-2 <br />RTU-6 <br />RTU-7RTU-3 <br />RTU-2RTU-1 <br />67 <br />CU-8 <br />CCER-7 <br />7 <br />CU-5B <br />CCWDP-14,16 <br />30A/1PH/208V/F/NE <br />MA 4XSS <br />CCWDP-13,15,17 <br />CCEDP-14,16 <br />30A/1PH/208V/F/NEMA 4XSS <br />3#8, 1#10G, 3/4"C <br />3#1, 1#8G, 1-1/2"C <br />3#8, 1#10G, 3/4"C 3#6, 1#8G, 1"C 3#10, 1#10G, 3/4"C <br />3#8, 1#10G, 3/4"C <br />3#2/0, 1#6G, 2"C <br />3#2/0, 1#6G, 2"C <br />3#8, 1#10G, 3/4"C <br />CU-1 <br />3#10, 1#10G, 3/4"C <br />COORDINATE VFDS LOCATIONS <br />WITH MECHANICAL DRAWINGS <br />FIELD COORDINATE EXACT <br />DISCONNECT LOCATION <br />(TYPICAL) <br />WP WP WP WP <br />EF-1 <br />1 <br />30A/1P/120V/F/NEMA 4XSS <br />30A/3P/208V/F/NEMA 4XSS <br />KEF-1 <br />CCWDP-22,24,26 <br />CCWR-10 <br />CCWR-67 <br />1 <br />1 1 <br />2 <br />CCEDP-2,4,6 <br />1 <br />12 <br />2 <br />2 <br />2 <br />1 PROVIDE RECEPTACLES WITHIN 25FT OF ALL MECHANICAL EQUIPMENT ON THE ROOF. CONNECT ANY ADDITIONAL THAT MAY BE REQUIRED TO THIS CIRCUIT. <br />POWER KEYNOTES: <br />2 MOUNT DISCONNECTS TO ENSURE NEC REQUIRED CLEARANCES ARE MET, TYPICAL. COORDINATE LOCATIONS OF VFDS WITH VENDORS. 1 <br />H I J K L <br />2 <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 /1 5 /2 0 1 9 2 :2 0 :3 0 P M <br />C :\_R e v i t \E L E C - G A T E W A Y - v 2 0 1 8 _g s e i l e r A 6 Y M L .r v t <br />E11-01 <br />LEVEL 02 -ELECTRICAL <br />POWER PLAN <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />1/8" = 1'-0"1 LEVEL 02 - Power - Elevator Area <br />1/8" = 1'-0"2 LEVEL 02 - Power - Parapet AREA <br />1/8" = 1'-0"3 LEVEL 04 - Power <br />NO.ISSUE DATE <br />PERMIT SET 12.06.2018 <br />1 Revision 1 01.09.2019 <br />1 <br />2