Laserfiche WebLink
Activity ID Activity Name Performance % <br />Complete <br />Original <br />Duration <br />Early Start Early Finish Late Start Late Finish Total Float <br />05400-A PREPARE/SUBMIT - MISC. METALS 90%20d 21-Nov-14 24-Nov-14 13-Apr-15 14-Apr-15 95d <br />07240-A PREPARE/SUBMIT - EIFS 100%10d 21-Nov-14 20-Nov-14 01-Oct-14 30-Sep-14 -37d <br />07410-A PREPARE/SUBMIT - METAL PANELS 0%20d 21-Nov-14 22-Dec-14 05-Mar-15 01-Apr-15 68d <br />07500-A PREPARE/SUBMIT - ROOFING 30%20d 21-Nov-14 12-Dec-14 13-Apr-15 30-Apr-15 95d <br />08200-A PREPARE/SUBMIT - H.M. DOORS & FRAMES 100%10d 21-Nov-14 20-Nov-14 30-Sep-14 29-Sep-14 -38d <br />08300-A PREPARE/SUBMIT - OVERHEAD DOORS 100%10d 21-Nov-14 20-Nov-14 30-Jul-15 29-Jul-15 171d <br />08400-A PREPARE/SUBMIT - AUTOMATIC DOORS 100%10d 21-Nov-14 20-Nov-14 14-May-15 13-May-15 118d <br />08500-A PREPARE/SUBMIT - GLASS & GLAZING 100%10d 21-Nov-14 20-Nov-14 15-Oct-14 14-Oct-14 -27d <br />08700-A PREPARE/SUBMIT - FINISH HARDWARE 100%10d 21-Nov-14 20-Nov-14 13-Oct-14 10-Oct-14 -29d <br />09100-A PREPARE/SUBMIT - PLASTER & STUCCO 100%10d 21-Nov-14 20-Nov-14 08-Oct-14 07-Oct-14 -32d <br />09250-A PREPARE/SUBMIT - DRYWALL 100%10d 21-Nov-14 20-Nov-14 13-Nov-14 12-Nov-14 -6d <br />09300-A PREPARE/SUBMIT - TILE 100%10d 21-Nov-14 20-Nov-14 14-May-15 13-May-15 118d <br />09510-A PREPARE/SUBMIT - ACOUSTICAL CEILINGS 0%10d 21-Nov-14 08-Dec-14 29-Jan-15 11-Feb-15 43d <br />09650-A PREPARE/SUBMIT - RESILIENT FLOORING 100%10d 21-Nov-14 20-Nov-14 23-Jul-15 22-Jul-15 166d <br />09900-A PREPARE/SUBMIT - PAINTING 90%10d 21-Nov-14 21-Nov-14 14-Nov-14 14-Nov-14 -5d <br />10400-A PREPARE/SUBMIT - SIGNS 100%10d 21-Nov-14 20-Nov-14 01-Oct-14 30-Sep-14 -37d <br />10700-A PREPARE/SUBMIT - LOUVERS 100%10d 21-Nov-14 20-Nov-14 24-Oct-14 23-Oct-14 -20d <br />12490-A PREPARE/SUBMIT - BLINDS 100%10d 21-Nov-14 20-Nov-14 15-Oct-14 14-Oct-14 -27d <br />13200-A PREPARE/SUBMIT - SAFETY NET (HELI-PAD)0%20d 21-Nov-14 22-Dec-14 13-May-15 10-Jun-15 117d <br />15300-A PREPARE/SUBMIT - FIRE PROTECTION 100%20d 21-Nov-14 20-Nov-14 29-Dec-14 24-Dec-14 22d <br />15400-A PREPARE/SUBMIT - PLUMBING 100%20d 21-Nov-14 20-Nov-14 08-Oct-14 07-Oct-14 -32d <br />15800-A PREPARE/SUBMIT - HVAC 100%20d 21-Nov-14 20-Nov-14 09-Jan-15 08-Jan-15 29d <br />16100-A PREPARE/SUBMIT - ELECTRICAL 100%20d 21-Nov-14 20-Nov-14 28-Jan-15 27-Jan-15 42d <br />ARCHITECT - REVIEW/APPROVEARCHITECT - REVIEW/APPROVE 97.61%224d 21-Nov-14 09-Jan-15 30-Sep-14 31-Aug-15 166d <br />01800-B ARCHITECT REVIEW/APPROVE - SITE PLAN 100%10d 21-Nov-14 20-Nov-14 02-Oct-14 01-Oct-14 -36d <br />03300-B ARCHITECT REVIEW/APPROVE - CONCRETE 100%15d 21-Nov-14 20-Nov-14 21-May-15 20-May-15 123d <br />03310-B ARCHITECT REVIEW/APPROVE - REBAR 100%15d 21-Nov-14 20-Nov-14 21-May-15 20-May-15 123d <br />04200-B ARCHITECT REVIEW/APPROVE - MASONRY 100%10d 21-Nov-14 20-Nov-14 02-Oct-14 01-Oct-14 -36d <br />07240-B ARCHITECT REVIEW/APPROVE - EIFS 100%10d 21-Nov-14 20-Nov-14 01-Oct-14 30-Sep-14 -37d <br />08200-B ARCHITECT REVIEW/APPROVE - H.M. DOORS & <br />FRAMES <br />90%10d 21-Nov-14 21-Nov-14 30-Sep-14 30-Sep-14 -38d <br />08300-B ARCHITECT REVIEW/APPROVE - OVERHEAD <br />DOORS <br />90%10d 21-Nov-14 21-Nov-14 30-Jul-15 30-Jul-15 171d <br />08400-B ARCHITECT REVIEW/APPROVE - AUTOMATIC <br />DOORS <br />100%10d 21-Nov-14 20-Nov-14 14-May-15 13-May-15 118d <br />08500-B ARCHITECT REVIEW/APPROVE - GLASS & <br />GLAZING <br />100%10d 21-Nov-14 20-Nov-14 15-Oct-14 14-Oct-14 -27d <br />08700-B ARCHITECT REVIEW/APPROVE - FINISH <br />HARDWARE <br />90%10d 21-Nov-14 21-Nov-14 13-Oct-14 13-Oct-14 -29d <br />Jan F Mar Apr May Jun Jul Aug S Oct N Dec Jan F Mar Apr May Jun Jul Aug S Oct N Dec Jan F MarApr <br />2014 2015 2016 <br />PREPARE/SUBMIT - MISC. METALS <br />PREPARE/SUBMIT - EIFS <br />PREPARE/SUBMIT - METAL PANELS <br />PREPARE/SUBMIT - ROOFING <br />PREPARE/SUBMIT - H.M. DOORS & FRAMES <br />PREPARE/SUBMIT - OVERHEAD DOORS <br />PREPARE/SUBMIT - AUTOMATIC DOORS <br />PREPARE/SUBMIT - GLASS & GLAZING <br />PREPARE/SUBMIT - FINISH HARDWARE <br />PREPARE/SUBMIT - PLASTER & STUCCO <br />PREPARE/SUBMIT - DRYWALL <br />PREPARE/SUBMIT - TILE <br />PREPARE/SUBMIT - ACOUSTICAL CEILINGS <br />PREPARE/SUBMIT - RESILIENT FLOORING <br />PREPARE/SUBMIT - PAINTING <br />PREPARE/SUBMIT - SIGNS <br />PREPARE/SUBMIT - LOUVERS <br />PREPARE/SUBMIT - BLINDS <br />PREPARE/SUBMIT - SAFETY NET (HELI-PAD) <br />PREPARE/SUBMIT - FIRE PROTECTION <br />PREPARE/SUBMIT - PLUMBING <br />PREPARE/SUBMIT - HVAC <br />PREPARE/SUBMIT - ELECTRICAL <br />07-Jan-15, ARCHITECT - REVIEW/APPROVE <br />ARCHITECT REVIEW/APPROVE - SITE PLAN <br />ARCHITECT REVIEW/APPROVE - CONCRETE <br />ARCHITECT REVIEW/APPROVE - REBAR <br />ARCHITECT REVIEW/APPROVE - MASONRY <br />ARCHITECT REVIEW/APPROVE - EIFS <br />ARCHITECT REVIEW/APPROVE - H.M. DOORS & FRAMES <br />ARCHITECT REVIEW/APPROVE - OVERHEAD DOORS <br />ARCHITECT REVIEW/APPROVE - AUTOMATIC DOORS <br />ARCHITECT REVIEW/APPROVE - GLASS & GLAZING <br />ARCHITECT REVIEW/APPROVE - FINISH HARDWARE <br />Actual Level of Effort <br />Actual Work <br />Remaining Work <br />Critical Remaining Work <br />START DATE 06-Dec-13, FINISH DATE 12-Feb-16 <br />DATA DATE 21-Nov-14, RUN DATE 25-Aug-17 <br />PAGE 2 OF 26