My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment B - Sunny Isles Bldg Dept Annex, Bid Set
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(25-01-01) City Annex Building Construction Renovations
>
INVITATION TO BID 25-01-01 CITY ANNEX BUILDING CONSTRUCTION RENOVATIONS
>
Attachment B - Sunny Isles Bldg Dept Annex, Bid Set
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 9:15:56 AM
Creation date
2/20/2025 9:10:25 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
City Annex Building Construction Renovations
Bid No. (xx-xx-xx)
25-01-01
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 7 8 9 <br />A <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />J <br />K <br />L <br />M <br />N8'-0"8'-9"7'-9"9'-10"7'-5"14'-8"2'-10"9'-6"12'-11"5'-0"9'-7"96'-3"7'-2"15'-10"3'-7"3'-11"15'-7"29'-3"28'-2" <br />109'-2" <br />5'-8" <br />COLUMN <br />EXISTING <br />TO REMAIN <br />P2 <br />P4 <br />P3 <br />P5 <br />P1 <br />COLUMNEXISTINGTO REMAIN http://www.beai.comPHONE: (305) 461-2053LICENSE No. AA26001612Miami, Florida 3316811575 Northwest 7 AvenueFAX: (305) 634-0599 E-mail: info@beai.comBEA architects Inc.© NOVEMBER 2024 ADRIAN PRICE FL. LICENSE #AR97981CITY OF SUNNY ISLES BEACH18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011 <br />BID SET BUILDING DEPARTMENT RELOCATIONTO ANNEXLIFE SAFETY PLAN <br />P.L.A.P. <br />AS SHOWN <br />LIFE SAFETY PLAN <br />LS-101 <br />N <br />1/8"=1'-0"1 <br />LIFE SAFETY NOTES: <br />1. THE BUILDING SHALL NOT BE OCCUPIED AND SHALL REMAIN CLOSED <br />TO THE PUBLIC UNTIL SUBSTANTIAL COMPLETION IS ACHIEVED. <br />2. (NFPA1:13.6.1.2) PORTABLE FIRE EXTINGUISHERS ARE NOT REQUIRED IN <br />SEATING OR OUTDOOR PERFORMANCE AREAS. <br />3. (NFPA1:13.6.3.2.1) ALL FIRE EXTINGUISHERS PROVIDED WILL BE A MIN <br />2-A, ONE FIRE EXTINGUISHER SHALL BE PROVIDED FOR EVERY 3,000 SF, <br />WITH A MAXIMUM DISTANCE OF TRAVEL DISTANCE NOT EXCEEDING <br />75'-0". <br />4. (NFPA1:13.6.3.1.3.8) TOP OF EXTINGUISHER NOT TO EXCEED 5'-0" ABOVE <br />FLOOR FINISH. <br />5. FOR FIRE EXTINGUISHER DETAILS, FINAL LOCATION & REQUIRED <br />NUMBER SUBJECT TO AHJ. <br />6. PORTABLE FIRE EXTINGUISHERS SHALL MEET THE REQUIREMENTS OF <br />MDFD AND NFPA 101. <br />EMERGENCY LIGHTING NOTES: <br />1. EMERGENCY LIGHTING IN BUSINESS OCCUPANCIES SHALL BE IN <br />ACCORDANCE WITH FBC 2023 1008.3 (EMERGENCY POWER FOR <br />ILLUMINATION). EMERGENCY LIGHTING IS REQUIRED FOR ALL MEANS OF <br />EGRESS: THE FLOORS AND OTHER WALKING SURFACES WITHIN AN EXIT <br />AND WITHIN THE PORTIONS OF THE EXIT ACCESS AND EXIT DISCHARGE <br />DESIGNATED IN SECTION SHALL BE ILLUMINATED TO VALUES OF AT <br />LEAST 1 FOOTCANDLE MEASURED AT THE FLOOR. DURING CONDITIONS <br />OF STAIR USE, THE MINIMUM ILLUMINATION FOR NEW STAIRS SHALL BE <br />AT LEAST 10 FOOT-CANDLE, MEASURED AT THE WALKING SURFACE. IN <br />BUSINESS OCCUPANCIES, THE ILLUMINATION OF THE FLOORS OF EXIT <br />ACCESS SHALL BE AT LEAST 0.2 FOOTCANDLE DURING PERIODS OF <br />PERFORMANCES OR PROJECTIONS INVOLVING DIRECTED LIGHT. <br />2. EXIT SIGNS: (FBC 2023 SECTION 1013) EXIT SIGNS. EXITS SHALL BE <br />MARKED BY AN APPROVED SIGN READILY VISIBLE FROM ANY DIRECTION <br />OF EXIT ACCESS. EVERY EXIT SIGN SHALL BE SUITABLY ILLUMINATED BY <br />A RELIABLE LIGHT SOURCE. EXTERNALLY AND INTERNALLY ILLUMINATED <br />SIGNS SHALL BE VISIBLE IN BOTH NORMAL AND EMERGENCY LIGHTING. <br />EXCEPTION: MAIN EXTERIOR EXIT DOORS THAT OBVIOUSLY AND <br />CLEARLY ARE IDENTIFIABLE AS EXITS. <br />3. COORDINATE WITH ELECTRICAL DRAWINGS AS REQUIRED. <br />EGRESS NOTES: <br />1. ALL EXIT DOORS TO OPERATE WITH PANIC HARDWARE. SEE DOOR <br />SCHEDULE <br />2.12" MAX. THRESHOLD DIFFERENTIAL AT ALL EXTERIOR DOORS. <br />SHADING LEGEND <br />FLAME SPREAD CLASS REQUIREMENT <br />LOCATION CLASS <br />EXIT CORRIDORS <br />ROOMS <br />B <br />C <br /> NOTES: <br />1. ALL INTERIOR PARTITIONS SHALL HAVE A MINIMUM OF CLASS B <br />FLAME SPREAD AS PER SECTION 803.1.2. OF THE FLORIDA <br />BUILDING CODE 2023. <br />2. STORAGE CONSTRUCTED ENTIRELY OF WOOD AND OF <br />NONCOMBUSTIBLE MATERIALS SHALL HAVE A MINIMUM OF <br />CLASS B FLAME SPREAD. <br />3. ALL CARPET SHALL HAVE NOT LESS THAN CLASS B FLAME <br />SPREAD. <br />4. ALL FINISHES IN BUSINESS AREAS SHALL FOLLOW CHAPTER 38, <br />FFPC 2023 <br />CIRCULATION AREAS / <br />FIXED FURNITURE / <br />RESTROOMS <br />NON-HATCHED = <br />OCCUPANCY CALCULATION PER NFPA 101 TABLE 7.3.1.2 & FBC 2023 TABLE 1004.5 <br />MARK AREA ASSEMBLY/USE <br />AREA PER <br />OCCUPANT OCCUPANCY <br />001 6,696 SF BUSINESS USE 150 SF <br />BUILDING DATA <br />CONSTRUCTION TYPE: <br />OCCUPANCY GROUP: <br />VB (SPRINKLERED) <br />MAXIMUM EXIT TRAVEL <br />DISTANCE: <br />ALLOWABLE BUILDING <br />HEIGHT AND AREA <br />APPLICABLE CODES: <br />B - BUSINESS <br />F.B.C. 2023 <br />60 FT ALLOWABLE HEIGHT, <br />3 STORIES, WITH 36,000 SF <br />ALLOWABLE AREA <br />TOTAL BUILDING AREA 9,312.2 SF <br />FIRE RESISTENCE <br />RATING REQUIREMENT <br />FOR BUILDING <br />ELEMENTS <br />0 hr - STRUCTURAL FRAME <br />0 hr - BEARING WALLS (EXT) <br />0 hr - BEARING WALLS (INT) <br />0 hr - NONBEARING WALLS AND <br />PARITITIONS (INT) <br />0 hr - FLOOR CONSTRUCTION <br />OCCUPANCY <br />CLASSIFICATION <br />SINGLE LEVEL <br />SPRINKLER OCCUPANCIES <br />TOTAL BUILDING HEIGHT +27'-0" <br />NATIONAL FIRE PROTECTION <br />ASSOCIATION CODES AND STANDARDS <br />2021 EDITION <br />300 FT <br />(F.B.C. 2023 TABLE 1017.2) <br />TOTAL EXIT CAPACITY <br />FLOOR LEVEL TOTAL EXITING <br />OCCUPANCY LOAD <br />TOTAL EXIT <br />CAPACITY <br />BUSINESS <br /> AREA 1,200 OCCUPANTS45 OCCUPANTS <br />2,400 OCCUPANTS <br />TABLE 504.3, 504.4 & 506.2 <br />FLORIDA BUILDING CODE 2023 <br />EDITION (8TH EDITION <br />BUSINESS USE <br />SYMBOLS LEGEND <br />P# FURTHEST POINT FROM EXIT <br />EXIT # POINT OF EXIT FROM BLDG. <br />EGRESS FROM AREA AND <br />DIRECTION OF TRAVEL <br />CLEAR WIDTH OF <br />EGRESS COMPONENT <br />TOTAL NUMBER OF <br />OCCUPANTS EXITING <br />MAX. EXIT CAPACITY <br />ALLOWABLE <br /># #FT. <br />CAPACITY EXITINGSIZE <br />EGRESS COMPONENT <br />WALL MOUNTED EXIT SIGN. <br />SHADE DENOTES FACE READ <br />ARROW INDICATES EXIT DIRECT <br />EXTINGUISHER INSTALL TOP <br />OF CABINET AT 42" A.F.F. <br />SUBMIT SHOP DWGS <br />CEILING MOUNTED EXIT SIGN. <br />SHADE DENOTES FACE READ <br />ARROW INDICATES EXIT DIRECT <br /> NOTES: <br />TEMPORARY STRUCTURES SHALL BE LOCATED IN <br />ACCORDANCE WITH THE REQUIREMENTS OF TABLE 602 <br />BASED ON THE FIRE-RESISTANCE RATING OF THE EXTERIOR <br />WALLS FOR THE PROPOSED TYPE OF CONSTRUCTION. <br />GENERAL NOTES: <br />1. A PERMIT APPLICATION AND CONSTRUCTION DOCUMENTS SHALL BE <br />SUBMITTED FOR EACH INSTALLATION OF A TEMPORARY STRUCTURE. <br />THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A SITE PLAN <br />INDICATING THE LOCATION OF THE TEMPORARY STRUCTURE AND <br />INFORMATION DELINEATING THE MEANS OF EGRESS AND THE <br />OCCUPANT LOAD. <br />2. ALL PENETRATIONS THROUGH ANY FIRE RATED WALL OR CEILING <br />ASSEMBLY SHALL BE PROTECTED BY A UL APPROVED THROUGH <br />PENETRATION FIRE STOP SYSTEM TO ACHIEVE THE SAME FIRE RATING <br />OF THE BUILDING ELEMENT BEING PENETRATED. <br />3. EXISTING FIRE RATINGS NOT SHOWN <br />4. INTERIOR FINISH DIMENSIONS OF TRAILER MAY VARY DEPENDING ON <br />MANUFACTURER SPECIFICATIONS. <br />5. G.C.TO COORDINATE REQUIRED DISTANCES AND DIMENSIONS FOR NEW <br />FLOORING. <br />6. G.G. TO SUBMIT PRODUCT SPECIFICATIONS, DATA AND SAMPLES FOR <br />APPROVAL PRIOR TO ORDER AND INSTALLATION. <br />7. ALL CARPET SHALL HAVE NOT LESS THAN CLASS B FLAME SPREAD. <br />8. INTERIOR FINISHES FOR WALLS, CEILINGS, AND FLOORS SHALL COMPLY <br />WITH REQUIREMENT FOR FBC 2023 CHAPTER 8 INTERIOR FINISHES. <br />ROOM NAME <br />WORK AREA <br />CIRCULATION AND RESTROOM <br />PLUMBING FIXTURE MINIMUM REQUIREMENTS <br />OCCUPANCY CLASSIFICATION WATER CLOSET LAVATORIES BATHTUBS/ <br />SHOWERS <br />DRINKING FOUNTAIN <br />(SEE SECTION 410)OTHER <br />MALE FEMALE UNISEX MALE FEMALE UNISEX <br />BUSINESS 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE <br />REMAINDER EXCEEDING 50 <br />1 PER 40 FOR THE FIRST 80 AND 1 PER SO FOR THE <br />REMAINDER EXCEEDING 80 -1 PER 100 1 SERVICE SINK <br />REQUIRED TOTAL: <br />45 OCCUPANTS / 2 <br />= 22.5 MALE AND 22.5 <br />FEMALE <br />1 1 0 1 1 0 -SEE NOTE #3 1 SERVICE SINK <br />PROVIDED 1 1 1 1 1 1 -2 1 SERVICE SINK <br />ASSEMBLY 1 per 75 1 per 200 -1 per 500 1 SERVICE SINK <br />REQUIRED 1 1 0 1 1 0 -1 1 <br />PROVIDED 1 1 0 1 1 0 -0 1 <br />NOTES: <br />1. FBC 2023 PLUMBING - SECTION 403 <br />2. FBC 2023 PLUMBING - SECTION 403.1 <br />3. DRINKING FOUNTAINS SHALL NOT BE REQUIRED FOR AN OCCUPANT LOAD OF 15 OR FEWER. - FBC 2023 PLUMBING (SECTION 410.2) <br />4. SEPARATE FACILITIES SHALL NOT BE REQUIRED IN STRUCTURES OR TENANT SPACES WITH A TOTAL OCCUPANT LOAD, INCLUDING BOTH EMPLOYEES AND <br /> CUSTOMERS, OF 15 OR FEWER. - FBC 2023 PLUMBING (SECTION 403.2) <br />5. SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESS OCCUPANCIES IN WHICH THE MAXIMUM OCCUPANT LOAD IS 25 OR FEWER. <br /> - FBC 2023 PLUMBING (SECTION 403.2) <br />FIRE RESISTENCE <br />RATING REQUIREMENT <br />FOR EXTERIOR WALLS <br />BASED ON FIRE <br />SEPARATION DISTANCE <br />PER F.B.C. 2023 <br />TABLE 705.5 <br />X ≥ 30 <br />OCCUPANCY GROUP B = 0 HOUR <br />CAPACITY EXITINGSIZE <br />480 186'-0" <br />(2) 36" DOOR <br />3 <br />CAPACITY EXITINGSIZE <br />240 93'-0" <br />(1) 36" DOOR <br />1 <br />002 CAFE <br />TOTAL 8,323 SF -- <br />003 STORAGE <br />004 RESTROOM/ CIRCULATION <br />STORAGE USE 150 SF <br />-- <br />45 <br />- <br />1 <br />45 <br />STORAGE USE <br />ASSEMBLY (UNCONCENTRATED) <br />FE <br />FE <br />FE <br />FE <br />978 SF <br />126 SF <br />523 SF <br />KEY PLAN <br />N <br />1/32"=1'-0"2 <br />15 NET 66ASSEMBLY <br />UNCONCENTRATED USE <br />CAPACITY EXITINGSIZE <br />240 93'-0" <br />(1) 36" DOOR <br />2 <br />WATER HEATER <br />ROOM <br />ELECTRICAL <br />ROOM <br />113 SQFT <br />030 <br />PLAN EXAMINERSTRUCTURE <br />116 SQFT <br />031 <br />COORDINATORPLAN <br />128 SQFT <br />022 <br />ROOMMEETING <br />122 SQFT <br />033 <br />SUPERVISORBUSINESS CENTER <br />378 SQFT <br />034 <br />ADMINISTRATORBUSINESS CENTER <br />78 SQFT <br />035 <br />STORAGE <br />48 SQFT <br />029 <br />IT ROOM <br />044 <br />/ LOBBYENTRANCE <br />646 SQFT <br />043 <br />WAITING AREA <br />156 SQFT <br />001 <br />OR DIRECTORBUILDING OFFICIAL <br />184 SQFT <br />017 <br />ROOMCONFERENCE <br />EGRESS <br />LIBRARY / FILES <br />(FLOOR TO CEILING HEIGHT) <br />133 SQFT <br />004 <br />BUILDING OFFICIALASSISTANT <br />1,024 SQFT <br />42 SQFT <br />041 <br />CLOSETJANITOR <br />FUTURE/ LEASEABLE <br />AREA <br />121 SQFT <br />010 <br />INSPECTORCHIEF ELECTRICAL <br />159 SQFT <br />002 <br />MANAGERBUILDING DEPT. <br />121 SQFT <br />009 <br />INSPECTORCHIEF MECHANICAL <br />33 SQFT <br />036 <br />CLOSETJANITOR <br />120 SQFT <br />007 <br />INSPECTORCHIEF BUILDING <br />121 SQFT <br />008 <br />INSPECTORCHIEF PLUMBING <br />EGRESS <br />401 SQFT <br />003 <br />BREAKROOM <br />69 SQFT <br />037 <br />RESTROOMWOMEN'SCALL CENTER <br />011 <br />181 SQFT <br />101 SQFT <br />032 <br />SUPERVISORPERMIT <br />EGRESS <br />BUILT-IN <br />SHELF <br />62 SQFT <br />042 <br />RESTROOMUNISEX <br />49 SQFT <br />040 <br />RESTROOMMEN'S <br />65 SQFT <br />005 <br />ADMIN <br />65 SQFT <br />006 <br />ADMIN <br />116 SQFT <br />012 <br />INSPECTORSR. BUILDING <br />81 SQFT <br />015 <br />INSPECTORSR. PLUMBING <br />81 SQFT <br />019 <br />INSPECTORMECHANICAL <br />81 SQFT <br />020 <br />INSPECTORSR. ELECTRICAL <br />81 SQFT <br />023 <br />INSPECTOR <br />81 SQFT <br />016 <br />INSPECTORPLUMBING <br />81 SQFT <br />021 <br />INSPECTORELECTRICAL <br />81 SQFT <br />018 <br />INSPECTORSR. MECHANICAL <br />116 SQFT <br />014 <br />ADMINISTRATORFLOOD PLAIN <br />116 SQFT <br />013 <br />INSPECTORBUILDING <br />81 SQFT <br />026 <br />INSPECTOR 81 SQFT <br />027 <br />INSPECTOR <br />81 SQFT <br />028 <br />PLAN EXAMINERSR. BUILDING <br />81 SQFT <br />024 <br />INSPECTOR <br />81 SQFT <br />025 <br />PLAN EXAMINERSR.BUILDING <br />(INCLUDING LEASABLE <br />SPACE) <br />108'-8" FROM <br />P1 TO EXIT 1 <br />64'-0" FROM <br />P2 TO EXIT 3 <br />62'-7" FROM <br />P4 TO EXIT 3 <br />71'-2" FROM <br />P5 TO EXIT 2 <br />FE <br />FE <br />FE <br />FE <br />69 SQFT <br />039 <br />RESTROOMWOMEN'S <br />69 SQFT <br />038 <br />RESTROOMMEN'S <br />CAPACITY EXITINGSIZE <br />480 226'-0" <br />(2) 36" DOOR <br />4 <br />CAPACITY EXITINGSIZE <br />480 226'-0" <br />(2) 36" DOOR <br />5 <br />CAPACITY EXITINGSIZE <br />240 93'-0" <br />(1) 36" DOOR <br />7 <br />91'-3" FROM <br />P3 TO EXIT 3 <br />F.B.C. 2023 <br />TABLE 601 <br />FBC TABLE 508.4 <br />REQUIRED SEPARATION OF OCCUPANTS <br />ASSEMBLY <br />BUSINESS <br />FUTURE LEASEABLE <br />AREA (NOT IN SCOPE) <br />BUILDING <br />DEPARTMENT <br />SPRINKLED <br />BUILDING <br />1 HOUR <br />TOTAL <br />ASSEMBLY 1,200 OCCUPANTS66 OCCUPANTS <br />111 OCCUPANTS <br />CAPACITY EXITINGSIZE <br />240 223'-0" <br />(1) 36" DOOR <br />6 <br />1-HR. FIRE RATED STRUCTURE <br />002 <br />003 004 <br />CEILING MOUNTED EXIT SIGN. <br />SHADE DENOTES FACE READ <br />WALL MOUNTED EXIT SIGN <br />SHADE DENOTES FACE READ <br />0011 HR1 HR1 HR 1 HR1 HR1 HR045 <br />046047
The URL can be used to link to this page
Your browser does not support the video tag.