Laserfiche WebLink
COLLINS AVENUE 1-STORY CBS #18050FFE = 7.80'CONCRETEDRIVEWAYCONCRETEDRIVEWAYGROUND0.5' CURB(TYPICAL)BRICKDRIVEWAYBRICKBRICKSIDEWALKBRICKSIDEWALKGROUNDGROUNDASPHALTPAVEMENT2'C&G(TYPICAL)BRICKSIDEWALKBRICKCONCRETESLABGROUNDGROUNDS86° 52' 22.53"W 140.00'S03° 07' 37.47"E14.43'S86° 52' 22.53"W 250.00'P-02P-03P-04P-05P-06P-07P-08P-09P-10P-11P-12P-14P-15P-13P-16P-17P-18P-19P-20P-21P-22P-23P-24P-25P-26T-32T-33T-34T-35T-38CB-03CB-06CB-05CB-04CB-07CB-0850.62'10.00'3.56'12.25'22.68'1.00'1.00'69.50'ASPHALTPAVEMENTCANVASAWNING8.50'44.45'7.25'24.36'4.21'1.00'79.70'S02° 58' 42.53"W 108.50 <br />'CONCRETESLAB100' TOTAL RIGHT OF W <br />A <br />Y S.I.B. GOVERNMENT CENTERPLAT BOOK 165 PAGE 75TRACT CMIAMI DADE PUBLIC RECORDSSUNNY ISLES SHORESPLAT BOOK 64 PAGE 74PARCEL 1S.I.B. GOVERNMENT CENTERPLAT BOOK 165 PAGE 75TRACT DGROUNDGROUNDGROUNDGROUNDCONCRETESLABCANVASAWNING14'-10" <br />18'-1"25'-1"2'C&GEOP33'-8"4'-10"18'-1"46'-7"73'-10"12'-9"23'-11"1.75'8'-1"6'-2"4'-9"79'-11"CANVASAWNINGDEMOLITION SITE PLANAD-100P.L.1/8" = 1'-0"DEMOLITION FLOOR PLAN11/8"=1'-0"N48 HOURS BEFORE YOU DIGCALL SUNSHINE1-800-432-4770IT'S THE LAW IN FLORIDADEMOLITION LEGENDEXISTING CONDITIONS TO REMAINPARTITION TO BE DEMOLISHEDEXISTING TO BE DEMOLISHEDEXISTING TO REMAINGENERAL DEMOLITION NOTES1. BEFORE BEGINING ANY DEMOLITION WORK, THE CONTRACTORSHALL SURVEY THE SITE AND EXAMINE THE DRAWINGS ANDSPECIFICATIONS TO DETERMINE THE EXTENT OF THE WORK.2. THE CONTRACTOR SHALL ENGINEER, CONSTRUCT ANDMAINTAIN SHORING, BRACING, AND SUPPORTS AS REQUIRED.3. UPON COMPLETION OF DEMOLITION, THE ENTIRE AREA SHALLBE CLEANED OF ALL DEBRIS AND PREPARED FOR NEWCONSTRUCTION.4. THE CONTRACTOR SHALL MAKE EVERY REASONABLE EFFORTTO PERFORM THE WORK AND MAINTAIN SAFETY TO THE PUBLICAND WORKERS, ALSO THE PROTECTION OF PROPERTYTHROUGHOUT CONSTRUCTION. ALL WORK SHALL BEPERFORMED IN ACCORDANCE WITH OSHA STANDARDS, ASAPPLICABLE.5. AT ALL TIMES DURING THE COURSE OF CONSTRUCTION, THECONTRACTOR SHALL MAINTAIN ENTRANCE AND EXIT ACCESSTO ALL FACILITIES AFFECTED BY THE CONSTRUCTION.6. COORDINATE WITH OWNER ALL BARRIERS FOR SECURITY,SAFETY AND PROTECTION, ALL WORK HOURS AND LOCATION OFDUMPSTER.7. ALL DISPOSAL OF EXCESS DEMOLITION, RUBBISH AND DEBRISSHALL BE MADE OUTSIDE THE LIMITS OF CONSTRUCTION AT ALEGAL DISPOSAL SITE PROVIDED BY THE CONTRACTOR.MATERIAL CLEARED FROM THE SITE SHALL NOT BE DEPOSITEDON ADJACENT AND/OR NEARBY PROPERTY.8. COORDINATE WITH ARCHITECTURE & ENGINEERINGCONSTRUCTION DRAWINGS AS REQUIRED FOR DEMOLITIONPURPOSES.9. COORDINATE WITH OWNER AND/OR UTILITY COMPANY FOREQUIPMENT RELOCATION/REMOVAL IMPACTING AREAS OUTSIDETHE LIMITS OF CONSTRUCTION.10. ALL MATERIALS TO BE REMOVED DURING DEMOLITION ANDREUSED LATER IN CONSTRUCTION; IS TO BE PROTECTED ANDRESTORED TO STANDARD ACCEPTABLE TO OWNER PRIORRE-INSTALLATION.11. ALL EXISTING CERAMIC FLOOR, WALL TILE, CARPET AND BASETO BE REMOVED THROUGHOUT THE SPACE.12. COORDINATE AREAS OF DEMOLITION BETWEEN ALL DEMOLITIONDRAWINGS.13. THE CONTRACTOR SHALL FIELD VERIFY ALL BUILDING SYSTEMS,STRUCTURE AND EXISTING CONDITIONS.14. GC TO COORDINATE REMOVAL AND /OR DISCONNECTION OF ALLCOMMUNICATION AND SECURITY DEVICES WITH SERVICEPROVIDER PRIOR TO COMMENCEMENT OF WORK.STRUCTURAL DEMOLITION NOTES15. ALL STRUCTURAL STEEL, FRAMING, ETC. WITHIN THEDESIGNATED DEMOLITION AREA SHALL BE DEMOLISHEDACCORDING TO SPECIFICATIONS. ALL DEMOLITION WITHINFOOTPRINT TO BE COORDINATED WITH THESE DRAWINGS ANDANY DISCREPANCIES SHALL BE REPORTED TO THEARCHITECT/ENGINEER.16. THE CONTRACTOR SHALL LIMIT THE ACCUMULATION OF DEBRISTO A MAXIMUM LOADING OF 100 P.S.F.17. CARE SHALL BE TAKEN DURING DEMOLITION SO AS NOT TODAMAGE OR ALTER ANY EXISTING ELEMENTS TO REMAIN. THEARCHITECT AND STRUCTURAL ENGINEER SHALL BE NOTIFIEDIMMEDIATELY IF ANY DAMAGE OCCURS OR IS DISCOVEREDDURING DEMOLITION.ELECTRICAL DEMOLITION NOTES18. COORDINATE W/ CITY PUBLIC WORKS DEPARTMENTS ASREQUIRED FOR DEMOLITION PURPOSES.19. THE ELECTRICAL CONTRACTOR SHALL EXERCISE EXTREMECAUTION TO DISCONNECT ALL ELECTRICAL SERVICE PRIOR TOANY DEMOLITION WORK.20. CONTACT FLORIDA POWER & LIGHT PRIOR TO DISCONNECT OFELECTRICAL SERVICE.21. CONTACT TELECOMMUNICATIONS PROVIDER PRIOR TODISCONNECT OF TELEPHONE SERVICE.22. ALL WORK SHALL BE COORDINATED WITH DEMOLITIONCONTRACTOR.23. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TODEMOLITION WORK TO DETERMINE THE SCOPE OF WORK.24. ARCHITECT'S DEMOLITION DRAWINGS ARE TO BE CAREFULLYSTUDIED AND ANY CONFLICTS WITH THE EXISTING ELECTRICALSYSTEM THAT MAY BE ANTICIPATED MUST BE BROUGHT TO THEARCHITECT'S ATTENTION.25. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT, LIGHTING ANDOTHER DEVICES THAT ARE SCHEDULED TO BE REMOVED SHALLBE DISCONNECTED AT THE ELECTRICAL PANEL.NOTES26. INTERIOR WALL TO BE DEMOLISHED27. DOOR TO BE DEMOLISHED28. BOLLARD TO BE DEMOLISHED29. EXISTING WALL TO REMAIN30. COLUMN TO REMAIN31. COLUMN TO BE REMOVED AND REPLACED32. EXISTING WALL TO BE DEMOLISHED33. DRAIN PIPE TO REMAIN34. FENCE AND GATE TO REMOVED AND REPLACED35. PERIMETER WALL TO REMAIN36. WINDOW TO REMAIN37. WINDOW TO BE DEMOLISHED38. FLOOR DRAIN TO REMAIN39. ALL INTERIOR WALL CLADDING AND FINISH COVERING TO BEDEMOLISHED DOWN TO STRUCTURE AND GC TO VERIFY THATTHE ENCLOSURE IS NOT A STRUCTURE.40. CEILING FRAMING STRUCTURE TO BE DEMOLISHED41. EXISTING CEILING TO BE DEMOLISHED42. LIGHTING FIXTURES TO BE DEMOLISHED43. GC SHALL FIELD VERIFY THAT ALL DEMOLITION WASCOMPLETED IN ACCORDANCE TO THE CONSTRUCTIONDOCUMENTS.TREE TO BEREMOVEDhttp://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t sNOVEMBER 2024ADRIAN PRICE <br /> FL. LICENSE #AR97981 <br />CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011BID SETBUILDING DEPARTMENT RELOCATION <br />TO ANNEXA.P.TREE TO BEREMOVEDTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINTREE TOREMAINSEE SHEET AD-101FOR INFORMATIONEXISTING BRICKSIDEWALK TO REMAINPARKING STRIPINGTO BE REPAINTEDSTREET STRIPINGTO BEREMOVED/GRINDED ASPHALT PAVEMENT TOBE DEMOLISHED SEECIVILEXISTING CONCRETETO BE DEMOLISHEDNOT IN SCOPENOT IN SCOPEEXISTING BRICKTO REMAINLIGHTING POLE TOBE REMOVEDTREE TOREMAINSEE CIVIL DWGSFOR ADDITIONALWORKCOORDINATE GASLINE RELOCATIONWITH GASCOMPANYEXISTING CONCRETETO BE DEMOLISHEDCURB TO BEDEMOLISHEDEXISTING CONCRETETO BE DEMOLISHEDEXISTING CANOPYTO BE DEMOLISHEDEXISTING CANOPYTO BE DEMOLISHEDEXISTING SIGN ONCONCRETE TO RENOVATEDNEW WOOD CLADDING ANDNUMBERSSEE NOTE #32