THRU-BEAM PHOTOELECTRIC SENSOR. RECEIVER.THRU-BEAM PHOTOELECTRIC SENSOR. TRANSMITTER.EXISTING UNDERGROUND SECONDARYEXISTING UNDERGROUND COMMUNICATIONSOF DIMENSIONS IS DIRECTED.INTERFERENCES.NEMA, ANSI, U.L., ETC.A. GENERAL PROVISIONSPANELSB. C. D. 4. MINIMUM CONDUCTORS SIZE SHALL BE #12 AWG.NEMA REQUIREMENTS.LIGHTING1. ALL WIRING SHALL BE COPPER.CONDUCTORS1. ALL WIRING SHALL BE INSTALLED IN APPROVED RACEWAYS.FROM AUTHORITIES HAVING JURISDICTION.2. MINIMUM CONDUIT SIZE SHALL BE 3/4" TRADE SIZE.4. EXPOSED CONDUITS SHALL BE RUN PARALLEL TO BUILDING LINES.AFTER A FIRE, AS REQUIRED BY ARTICLE 300-21 OF THE N.E.C.RACEWAYS7. PROVIDE CABLE SUPPORTS IN ACCORDANCE WITH ARTICLE 300 OF THE N.E.C.2. ALL PANELS SHALL HAVE TYPEWRITTEN CIRCUITS DIRECTORIES MOUNTED INSIDE OF DOOR.8. PROVIDE EXPANSION FITTINGS IN CONDUIT STRUCTURAL EXPANSION JOINTS.3. WIRES SIZE #10 AWG AND SMALLER SHALL BE STRANDED OR SOLID. WIRES SIZE #8 AND LARGER SHALL BE STRANDED.1. PROVIDE LIGHTING AND RECEPTACLES PANELS AS INDICATED ON THE PLANS AND AS SPECIFIED HEREIN. ALL PANELS SHALL BE DEAD FRONT, CIRCUIT BREAKER TYPE AND SHALL BEAR THE U.L. LABEL AS WELL AS MEET ALL APPLICABLE 2. CONDUCTORS SHALL BE RATED 600V. WITH TYPE THWN INSULATION.2. ALL WORK SHALL BE DONE IN CONFORMANCE WITH THE 2020 EDITION OF THE FLORIDA BUILDING CODE, 2017 EDITION OF 3. ALL EQUIPMENT AND MATERIALS PROVIDED SHALL BE NEW AND IN CONFORMANCE WITH APPLICABLE PROVISIONS OF 4. THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF OTHER TRADES SO AS TO AVOID 5. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL LAYOUT OF ELECTRICAL SYSTEMS. FIELD VERIFICATIONS 6. SECURE PERMITS AND INSPECTIONS REQUIRED BY STATE AND LOCAL LAWS AND ORDINANCES.7. UPON COMPLETION OF THE WORK, FURNISH TO THE OWNER CERTIFICATES OF FINAL INSPECTIONS AND APPROVALS 3. USE FLEXIBLE CONDUIT FOR SHORT FINAL CONNECTIONS TO VIBRATING EQUIPMENT SUCH AS MOTORS AND TRANSFORMERS. LIQUID-TIGHT FLEXIBLE CONDUIT SHALL BE USED IN DAMP AND WET LOCATIONS.5. DO NOT INSTALL CONDUITS LARGER THAN 1/3 THE SLAB THICKNESS IN CONCRETE SLABS.1. THE WORK SHALL CONSIST OF FURNISHING LABOR, EQUIPMENT, AND MATERIALS TO PROVIDE THE COMPLETE THE NATIONAL ELECTRICAL CODE, ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS AND ORDINANCES.INTERGRATED AND PROPER FUNCTIONS SYSTEMS AS SHOWN ON THE DRAWINGS.6. PROVIDE APPROVED FIRE STOPPING MATERIALS AT ALL PENETRATIONS THROUGH FIRE RATED FLOORS AND WALLS TO PREVENT THE PASSAGE OF SMOKE, FIRE, TOXIC GAS OR WATER THROUGH THE PENETRATION EITHER BEFORE, DURING OR SWITCHESE. SAFETYFUSESF. G.2. FUSES RATED 0 TO 600 AMPS SHALL BE AS FOLLOW:SITE VISITBE NEMA 3R.PERMITTED.1. ALL FUSES SHALL HAVE A 200,000 AMP RMS SYMETRICAL RATING UNLESS OTHERWISE NOTED.a) CIRCUIT BREAKER PANEL PROTECTION-U.L. CLASS RK-1, DUAL ELEMENT(BUSSMANN "LOW PEAK" OR EQUAL).b) MOTOR CIRCUIT PROTECTION-U.L. CLASS RK-5, DUAL ELEMENT (BUSSMANN "FUSETRON" OR EQUAL).3. FUSES RATED 601 AMPS OR LARGER SHALL BE U.L. CLASS L TIME DELAY (BUSSMANN "HI-CAP" OR EQUAL).1. SAFETY SWITCHES SHALL BE HEAVY DUTY TYPE FUSIBLE OR NON-FUSIBLE WITH POLES, AMPERE AND SERVICES RATINGS AS INDICATED ON THE PLANS. LUGS SHALL BE U.L. LISTED FOR CU. -AL.1. BEFORE SUBMITTING A BID THE CONTRACTOR SHALL VISIT THE SITE AND DETERMINE CONDITIONS AT THE SITE AND ALLOWED FOR ADDITIONAL WORK REQUIRED BECAUSE OF CONTRACTOR'S FAILURE TO FULFILL THIS REQUIREMENT.2. ENCLOSURES FOR SAFETY SWITCHES SHALL BE NEMA 1, EXCEPT FOR SWITCHES MARKED "WP" (WEATHERPROOF) SHALL WRITING OF ANY DISCREPANCIES FOUND DURING SAID SITE VISIT. NO SUBSEQUENT INCREASE IN CONTRACT COST WILL BE WILL IN ANY WAY AFFECT THE WORK REQUIRED UNDER THE CONTRACT. THE CONTRACTOR SHALL INFORM THE ENGINEER INALL EXISTING STRUCTURES IN ORDER TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND ELECTRICAL SYSTEMS WHICH 4. ALL BREAKERS SHALL BE FULL SPACE, INDIVIDUAL FRAME TYPE. NO "PIGGY BACK" OR TANDEM BREAKERS WILL BE 3. PANELS SHALL BE SUITABLE FOR THE SERVICE RATING INDICATED ON THE PANEL SCHEDULES.WATERTIGHTWTLLF.LIGHT LOSS FACTORSECURITY CAMERAAND SECONDARY.COMBINED UNDERGROUND COMMUNICATIONSCLOCK (84" A.F.F. TO CENTER)ELECTRONIC SECURITY SYSTEM (48" A.F.F.)A.F.F E.W.H G.F.I. W.P.NL.U.O.N.MTD.MT.A.F.G. NIGHT LIGHTGROUND FAULT INTERRUPTERUNLESS OTHERWISE NOTEDWEATHERPROOFELECTRIC WATER HEATERABOVE FINISH GRADEABOVE FINISH FLOORMOUNTMOUNTEDLTG.TYP.PNL.TEL.FLUOR.GRD.CU.FIN.INC.TELEPHONEFLUORESCENTINCANDESCENTCOPPERGROUNDTYPICALFINISHLIGHTINGPANELDISTRIBUTION PANELDRY TYPE TRANSFORMERPANELBOARD (6'-0" AFF TO TOP)HEAT DETECTOR DUCT SMOKE DETECTORFIRE ALARM SPEAKERFIRE ALARM STROBE LIGHT (80" A.F.F.)SMOKE DETECTOR PUBLIC TELEPHONE (48" A.F.F.)UNDERGROUND COMMUNICATIONSUNDERGROUND SECONDARYELECTRIC HANDHOLETAMPER SWITCHFLOW SWITCHSHUT DOWN RELAYFIRE ALARM HORN FIRE ALARM CONTROL PANELREMOTE ANNUNCIATOR PANELP INDICATES PILOT LIGHTPMOTOR (3 PHASE) NUMBER INDICATES HORSEPOWEREXIT SIGN / EMERGENCY LIGHT COMBINATION UNIT.EXIT LIGHT - DIRECTIONAL ARROWS AS INDICATEDDUPLEX RECEPT. - NEMA 5-20R (18" A.F.F.TO CENTER)FLUORESCENT STRIP (BARE LAMP) - NIGHT LIGHTPOLE MOUNTED FIXTURE-NO. OF LUMINAIRES AS INDICATEDMAGNETIC STARTER (5'-6" A.F.F. TO TOP)DUPLEX RECEPT. MOUNTED ABOVE COUNTER - NEMA 5-20RSPECIAL PURPOSE RECEPT (18" A.F.F. TO CENTER) RATING AS NOTEDSINGLE POLE SWITCH - 20 AMP (48" A.F.F.TO CENTER)THREE WAY SWITCH - 20 AMP (48" A.F.F. TO CENTER)FUSIBLE DISCONNECT SWITCH POLES, AMPS AND FUSES AS SHOWNDUPLEX RECEPT. - NEMA 5-20R (FLOOR MTD.)FOUR WAY SWITCH - 20 AMP (48" A.F.F. TO CENTER)MANUAL STARTER-MT. 5'-6" A.F.F. TO TOP U.O.N.DIMMER SWITCH (48" A.F.F. TO CENTER)NF INDICATES NON-FUSEDJUNCTION BOXOR EMERGENCY LIGHT CIRCUIT.LIGHTING FIXTURE TYPEFLUORESCENT LIGHT FIXTURELIGHT FIXTURE CEILING MOUNTEDFLUORESCENT STRIP (BARE LAMP)EMERGENCY LIGHTING UNITWALL MOUNTED LIGHT FIXTURECEILING MOUNTED SPEAKERPUSHBUTTON STATION. OPEN-STOP-CLOSE.TIMER CONTROLLER-MT. 5'-6" A.F.F. TO TOPPHOTOELECTRIC CONTROLLERCONTACTOR-MT. 5'-6" TO TOPMT 48" A.F.F. TO CENTERLINEMOTOR (1 PHASE)WALL MOUNTED SPEAKERFIRE ALARM PULL STATION (48" A.F.F. TO CENTER)REMOTE TEST STATION FOR DUCT SMOKE DETECTORCOMPUTER OUTLET (18" A.F.F. TO CENTER)COMPUTER OUTLET FLUSH FLOOR MOUNTEDTELEVISION CABLE OUTLET (18" A.F.F. TO CENTER)TELEPHONE OUTLET (18" A.F.F. TO CENTER)TELEPHONE OUTLET - FLUSH FLOOR MOUNTEDCABLE TRAYOCCUPANCY SENSOR/WALL MTD. (PASSIVE INFRARED)OCCUPANCY SENSOR/WALL MTD. (ULTRA SONIC)OCCUPANCY SENSOR/WALL MTD.CFFLOOR MOUNTEDCEILING MOUNTEDQUAD RECEPT. - NEMA 5-20R (18" A.F.F.TO CENTER)JUNCTION BOX - FUTURE VIDEO CABLINGJUNCTION BOX - FUTURE AUDIO CABLING1000 SQ. FT. CEILING SENSORRELAY SWITCH PACKDRAWING INDEXLIGHTING CONTROL DETAIL (SEE SHEET E104)LIGHT SWITCH AS PER CORRESPONDING LIGHTINGCONTROL DETAIL REFERENCEElectrical General NotesE001http://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 <br />E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t sNOVEMBER 25, 2024CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011PERMIT SETBUILDING DEPARTMENT RELOCATION <br />TO ANNEX <br />THIS ITEM HAS BEEN DIGITALLY SIGNED AND <br />SEALED BY ALEX ROBINSON ON THE DATE <br />ADJACENT TO THE SEAL. PRINTED COPIES OF <br />THIS DOCUMENT ARE NOT CONSIDERED SIGNED <br />AND SEALED AND THE SIGNATURE MUST BE <br />VERIFIED ON ANY ELECTRONIC COPIES.www.hammondengineers.com499 N.W. 70thAvenue,Suite 215Plantation, Florida 33317