My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment B - Sunny Isles Bldg Dept Annex, Bid Set
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(25-01-01) City Annex Building Construction Renovations
>
INVITATION TO BID 25-01-01 CITY ANNEX BUILDING CONSTRUCTION RENOVATIONS
>
Attachment B - Sunny Isles Bldg Dept Annex, Bid Set
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 9:15:56 AM
Creation date
2/20/2025 9:10:25 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
City Annex Building Construction Renovations
Bid No. (xx-xx-xx)
25-01-01
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLERK #2WATER HEATERROOMELECTRICALROOMLIBRARY / FILES(FLOOR TO CEILING HEIGHT)1,044 SQFT(INTERIOR NOT IN SCOPE)CAFEEGRESSPLANPREPDESKLIBRARY / FILES <br />(FLOOR TO PARTITION HEIGHT) <br />LIBRARY / FILES <br />(FLOOR TO PARTITION HEIGHT)EGRESSCLERK #1EGRESS69 SQ FT037RESTROOMWOMENS69 SQ FT038RESTROOMMALE69 SQ FT039RESTROOMWOMENS62 SQ FT042UNISEXRESTROOM49 SQ FT040RESTROOMMALE42 SQ FT041CLOSETJANITOR33 SQ FT036CLOSETJANITOR78 SQ FT035STORAGE378 SQFT034ADMINISTRATORBUSINESS CENTER81 SQFT028PLAN EXAMINERSR. BUILDING81 SQFT027INSPECTOR81 SQFT026INSPECTOR116 SQFT013INSPECTORBUILDING65 SQFT006ADMIN65 SQFT005ADMIN101 SQFT032SUPERVISORPERMITCALL CENTER011181 SQFT401 SQFT003BREAKROOM121 SQFT008INSPECTORCHIEF PLUMBING116 SQFT014ADMINISTRATORFLOOD PLAIN120 SQFT007INSPECTORCHIEF BUILDING81 SQFT018INSPECTORSR. MECHANICAL121 SQFT009INSPECTORCHIEF MECHANICAL81 SQFT021INSPECTORELECTRICAL81 SQFT016INSPECTORPLUMBING81 SQFT023INSPECTOR81 SQFT020INSPECTORSR. ELECTRICAL159 SQFT002MANAGERBUILDING DEPT.121 SQFT010INSPECTORCHIEF ELECTRICAL81 SQFT025PLAN EXAMINERSR. BUILDING81 SQFT024INSPECTOR133 SQFT004BUILDING OFFICIALASSISTANT184 SQFT017ROOMCONFERENCE81 SQFT019INSPECTORMECHANICAL81 SQFT015INSPECTORSR. PLUMBING156 SQFT001OR DIRECTORBUILDING OFFICIAL633 SQFT043WAITING AREA044LOBBY / ENTRANCE48 SQFT029IT ROOM122 SQFT033SUPERVISORBUSINESS CENTER128 SQFT022ROOMMEETING116 SQFT031COORDINATORPLAN113 SQFT030PLAN EXAMINERSTRUCTURE116 SQFT012INSPECTORSR. BUILDINGK-6710WHITBYC_SINKSCAST IRON <br />K-6710WHITBYC_SINKSCAST IRON·······0'-6"PROVIDE PVC PREFORMED CONDUIT SPACERSAROUND ALL CONDUITS TO MAINTAIN SPACING.CARLON SNAP-N-STAC OR EQUAL. PROVIDE SUITABLEANCHORS DURING THE CONCRETE POUR TO PREVENTCONDUIT FROM FLOATING.MINIMUM 30" BELOW GRADE. REFER TO DUCTBANKINSTALLATION DETAIL, THIS SHEET.4" CONDUIT1'-4"1'-11"208V/600A FEEDERSEE RISERDUCTBANK6" WIDE WARNING TAPEBACKFILL AND COMPACT WITHSATISFACTORY SOILSBACK FILL AND COMPACT TRENCHWITH SUBBASE COURSE.EXISTING SUBBASEVARIES3" MIN. (TYP ALL AROUND PIPE)0'-6"PROVIDE PVC PREFORMED CONDUIT SPACERSAROUND ALL CONDUITS TO MAINTAIN SPACING.CARLON SNAP-N-STAC OR EQUAL. PROVIDE SUITABLEANCHORS DURING THE CONCRETE POUR TO PREVENTCONDUIT FROM FLOATING.MINIMUM 30" BELOW GRADE. REFER TO DUCTBANKINSTALLATION DETAIL, THIS SHEET.4" CONDUIT1'-4"4'-3 31/32"208V/600A FEEDER (FPL)SEE RISER208V/600A FEEDER (GEN)SEE RISER2" GENERATOR CONTROLS CONDUIT0'-6"PROVIDE PVC PREFORMED CONDUIT SPACERSAROUND ALL CONDUITS TO MAINTAIN SPACING.CARLON SNAP-N-STAC OR EQUAL. PROVIDE SUITABLEANCHORS DURING THE CONCRETE POUR TO PREVENTCONDUIT FROM FLOATING.MINIMUM 30" BELOW GRADE. REFER TO DUCTBANKINSTALLATION DETAIL, THIS SHEET.4" CONDUIT1'-4"3'-0 31/32"208V/600A FEEDER (GEN)SEE RISER2" GENERATOR CONTROLS CONDUITSECTION A-ASECTION B-BSECTION C-C2" GENERATOR ELECTRICAL CIRCUITS PANEL CONDUIT2" GENERATOR ELECTRICALCIRCUITS PANEL CONDUITElectrical Site PlanES100http://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 <br />E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t sNOVEMBER 25, 2024CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011BID SETBUILDING DEPARTMENT RELOCATION <br />TO ANNEX <br />THIS ITEM HAS BEEN DIGITALLY SIGNED AND <br />SEALED BY ALEX ROBINSON ON THE DATE <br />ADJACENT TO THE SEAL. PRINTED COPIES OF <br />THIS DOCUMENT ARE NOT CONSIDERED SIGNED <br />AND SEALED AND THE SIGNATURE MUST BE <br />VERIFIED ON ANY ELECTRONIC COPIES.www.hammondengineers.com499 N.W. 70thAvenue,Suite 215Plantation, Florida 33317ELECTRICAL SITE PLANSCALE: 3/16" = 1'-0"NGENERAL NOTES:1.MINIMUM 3" SEPARATION BETWEEN ALL CONDUITSROUTED BELOW GRADE. ENGINEERED BACKFILL TOBE PROVIDED MINIMUM 6" AROUND CONDUITS ANDTAMPERED TO PREVENT EARTH MOVEMENT.2.12" SEPARATION BETWEEN ALL LOW VOLTAGE,CONTROLS, POWER CONDUITS, OR FOREIGN SYSTEMROUTED ON SITE.3.CONTRACTOR SHALL IDENTIFY ALL BELOW GRADEUTILITIES PRIOR TO NEW WORK. COORDINATE EXACTROUTING IN FIELD.4.CONDUIT ROUTING SHOWN FOR REFERENCE ONLY.ELECTRICAL CONTRACTOR SHALL FIELDCOORDINATE EXACT ROUTING WITH OTHER EXISTINGAND NEW UTILITIES.DUCT BANK INSTALLATION DETAILSSCALE: 1/2" = 1'-0"WIND LOAD DESIGN SHALL BE 185MPH WIND.COLLAR BACKFILL AS REQUIRED BY POLEENGINEER. WIND LOAD DESIGN SHALL MEETCONTRACTOR SHALL PROVIDE CONCRETEMANUFACTURER REGISTERED STRUCTURALALL STATE, LOCAL AND SFBC CODES. MINIMUMCONCRETE POLE#6 GROUNDINGPIGTAIL (TYP)5/8"Ø X 10'COPPER CLADGROUND ROD