My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment A - 2015-3-13_Samson Park Technical Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(15-05-01) Samson Oceanfront Park Improvements
>
Attachment A - 2015-3-13_Samson Park Technical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2015 10:00:19 AM
Creation date
11/12/2015 9:46:40 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMSON OCEANFRONT PARK <br />CITY OF SUNNY ISLES <br />TECHNICAL SPECIFICATIONS <br />TRANSIENT VOLTAGE SUPPRESSION 16289 - 7 <br />2. LED indicator lights for reverse polarity and open outlet ground. <br />3. Circuit breaker and thermal fusing. When protection is lost, circuit opens and cannot be reset. <br />4. Circuit breaker and thermal fusing. Unit continues to supply power if protection is lost. <br />5. [Close-coupled direct plug-in] [Cord connected with 15-foot (4.5-m) line cord]. <br />6. Rocker-type on-off switch, illuminated when in the on position. <br />7. One RJ11/12C telephone line protector, suitable for modem connection. Maximum clamping <br />voltage 220 peak on pins No. 3 and 4. <br />B. Peak Single-Impulse Surge Current Rating: [33] [26] [13] kA per phase. <br />C. Protection modes and UL 1449 clamping voltage shall be as follows: <br />1. Line to Neutral: 475 V. <br />2. Line to Ground: 475 V. <br />3. Neutral to Ground: 475 V. <br />2.6 <br />A. Protectors for copper [control] [data] [antenna] [telephone] conductors entering the building <br />from the outside shall be as recommended by the manufacturer for the type of line being protected. <br />CONTROL AND DATA TERMINALS <br />2.7 <br />A. NEMA 250, with type matching the enclosure of panel or device being protected. <br />ENCLOSURES <br />PART 3 - EXECUTION <br />3.1 <br />A. Install devices at service entrance on load side, with ground lead bonded to service entrance <br />ground. <br />INSTALLATION OF SURGE PROTECTIVE DEVICES <br />B. Install devices for panelboard and auxiliary panels with conductors between suppressor and points <br />of attachment as short and straight as possible. Do not exceed manufacturer's recommended lead <br />length. Do not bond neutral and ground. <br />1. Provide multipole, 15-A circuit breaker as a dedicated disconnect for the suppressor, unless <br />otherwise indicated. <br />3.2 <br />A. Tighten electrical connectors and terminals according to manufacturer's published torque-tightening val- <br />ues. If manufacturer's torque values are not indicated, use those specified in UL 486A and UL 486B. <br />CONNECTIONS <br />3.3 <br />A. Testing: Owner will engage a qualified testing agency to perform the following field quality-control test- <br />ing: <br />FIELD QUALITY CONTROL
The URL can be used to link to this page
Your browser does not support the video tag.