My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment A - 2015-3-13_Samson Park Technical Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(15-05-01) Samson Oceanfront Park Improvements
>
Attachment A - 2015-3-13_Samson Park Technical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2015 10:00:19 AM
Creation date
11/12/2015 9:46:40 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7/2011 <br />15060 - 2 <br />As used herein, "ANSI" denotes the American National Standards Institute, "AWWA" denotes <br />the American Water Works Association, and "ASTM" denotes the American Society for <br />Testing and Materials. <br /> <br />All pipe and fittings to be furnished hereunder shall conform to the referenced ANSI and/or <br />AWWA Standard as modified herein, as appearing in the following sections. <br /> <br />All markings required on pipe and fittings, shall be clearly legible and located such that they <br />will not be hidden or destroyed when assembled into the intended system. <br /> <br /> B. PIPE <br /> <br />All pipe shall be ductile iron pipe conforming to ANSI/AWWA Standard C151/A21.51-02, <br />"Ductile-Iron Pipe, Centrifugally Cast, for Water". All pipe and fittings for water applications <br />shall be in full compliance with ANSI/NSF 61, "Drinking Water System Components-Health <br />Effects". Manufacturers shall maintain their NSF certification for the duration of the Contract <br />and any extensions thereof. <br /> <br />The pipe thickness and outside diameter of pipe for sanitary sewer and water usage shall <br />conform to Tables 1 and 2 (for push-on and mechanical joint pipe, respectively) of <br />ANSI/AWWA Standard C151/A21.51-02 for the following sizes (The pressure class specified <br />is the minimum permitted): <br /> <br />Size Pressure Class <br /> <br />4-inch through 12-inch 350 <br />14-inch through 20-inch 250 <br />24-inch 200 <br />30-inch through 54-inch 150 <br /> <br />For restrained joint pipe, the thickness of the pipe barrel remaining after grooves are cut, if <br />required in the design of restrained end joints, shall not be less than the nominal wall <br />thickness of equal sized non-restrained joint pipe as shown above. <br /> <br /> <br />Each piece of pipe shall be marked as required in Subsection 4.6 of AWWA C151-02. Letters <br />and numerals on pipe sizes 12-inch and smaller shall be not less than 3/8-inch. <br /> <br />The Water and Sewer Department absolutely reserves the right to require the use of <br />"thickness" class pipe or higher pressure class pipe in applications where in the opinion of <br />the Engineer (ie the Chief, Engineering Division, M-D WASD or his representative) such use <br />is in the best interest of the Department. The Engineer's decision in this regard shall be final. <br /> <br />A sufficient quantity of non-toxic vegetable soap lubricant shall be supplied with each <br />shipment of pipe. The soap lubricant shall be suitable for use in subaqueous trench <br />conditions. <br /> <br />For flanged ductile-iron pipe with integrally cast flanges or threaded flanges, the nominal wall <br />thickness of the pipe barrel shall be as specified in Section 3.3, "Joints and Accessories" <br />under "Flanged Joints", hereinbelow. <br />
The URL can be used to link to this page
Your browser does not support the video tag.