TEST HOLE # 23 GAS <br />TEST HOLE # 25C UNKNOWN <br />TEST HOLE # 26 UNKNOWN <br />TEST HOLE # 28A UNKNOWN <br />TEST HOLE # 29 FIBER OPTIC <br />TEST HOLE # 30 GAS <br />TEST HOLE # 31 STORM <br />TEST HOLE # 32 GAS <br />TEST HOLE # 37 GAS <br />TEST HOLE # 40 GAS <br />TEST HOLE # 43 GAS <br />TEST HOLE # 45A WATER <br />TEST HOLE # 46 GAS <br />TEST HOLE # 46A WATER <br />NOTE: TEST HOLE ALSO REVEALED A 2" PVC UNKNOWN, RUNNING NORTH-SOUTH, 0.85' WEST OF <br />PK. COVER = 1.72. PK SET OVER CROWN OF 8" GAS. <br />NOTE: TEST HOLE MOVED 4' WEST FORM REQUESTED LOCATION DUE TO CROSSWALK. <br />NOTE: PK SET OVER CROWN OF NORTHERN MOST 2" FIBER OPTIC CONDUIT. <br />NOTE: GAS REQUESTED AT THIS LOCATION. TEST HOLE REVEALED A 2" WRAPPED STEEL <br />UNKNOWN (POSSIBLE GAS) AT THIS LOCATION. PK SET OVER CROWN OF 2" UNKNOWN. <br />NOTE: GAS REQUESTED AT THIS LOCATION. TEST HOLE REVEALED A 2" PVC (GRAY) UNKNOWN <br />AT THIS LOCATION. PK SET OVER CROWN OF 2" UNKNOWN. SEE TEST HOLE 25B FOR GAS <br />INFORMATION. <br />NOTE: TEST HOLE MOVED 40' NORTH DUE TO VEGETATION AND FENCE IN MEDIAN. PK SET OVER <br />CROWN OF 8" GAS. <br />NOTE: TEST HOLE EXCAVATED ON ELECTRONIC SIGNAL AND GAS LOCATOR MARKS. TEST HOLE <br />REVEALED CONCRETE BELIEVED TO BE ON TOP OF GAS. DID NOT EXCAVATE FURTHER TO <br />AVOID DAMAGE TO UTILITY. PK SET OVER TOP OF CONCRETE. <br />NOTE: TEST HOLE MOVED 40' NORTH DUE TO TREES AND FENCE IN MEDIAN. PK SET OVER <br />CROWN OF 8" GAS. <br />NOTE: GAS REQUESTED AT THIS LOCATION. TEST HOLE REVEALED A 2" WRAPPED STEEL <br />UNKNOWN (POSSIBLE GAS) AT THIS LOCATION. PK SET OVER CROWN OF 2" UNKNOWN. <br />TEST HOLE NOTES <br />NOTE: UNABLE TO OBTAIN SIZE AND MATERIAL DUE TO EXCESSIVE GROUND WATER AND SOIL <br />CONDITION ENCOUNTERED IN TEST HOLE. PK SET OVER TOP OF UTILITY. <br />NOTE: UNABLE TO OBTAIN SIZE DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST <br />HOLE. PLANS INDICATE A 18" RCP STORM AT THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />UNABLE TO OBTAIN SIZE AND MATERIAL IN NEARBY INLET FULL OF WATER AND DEBRIS. <br />NOTE: UNABLE TO OBTAIN SIZE DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST <br />HOLE. PLANS INDICATE A 12" WATER AT THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />NOTE: TEST HOLE MOVED 4' NORTH DUE TO CONCRETE. TEST HOLE EXCAVATED ON GAS <br />LOCATOR MARKS. UNABLE TO OBTAIN SIZE AND MATERIAL DUE TO EXCESSIVE GROUND WATER <br />ENCOUNTERED IN TEST HOLE. PK SET OVER TOP OF UTILITY. <br />NOTE: TEST HOLE MOVED 4' NORTH DUE TO CONCRETE. UNABLE TO OBTAIN SIZE DUE TO <br />EXCESSIVE GROUND WATER ENCOUNTERED IN TEST HOLE. PLANS INDICATE A 12" WATER AT <br />THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />Page 5 of 7