TEST HOLE # 48 GAS <br />TEST HOLE # 53A SANITARY <br />TEST HOLE # 57 GAS <br />TEST HOLE # 58 STORM <br />TEST HOLE # 61 STORM <br />TEST HOLE # 62 WATER <br />TEST HOLE # 64 TELEPHONE <br />TEST HOLE # 67 GAS <br />TEST HOLE # 70 GAS <br />TEST HOLE # 71 WATER <br />TEST HOLE # 78 GAS <br />TEST HOLE # 80 SANITARY <br />NOTE: UNABLE TO OBTAIN SIZE DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST <br />HOLE. PLANS INDICATE A 8" GAS AT THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />NOTE: TEST HOLE EXCAVATED ON SANITARY. UNABLE TO OBTAIN SIZE AND MATERIAL DUE TO <br />EXCESSIVE GROUND WATER ENCOUNTERED IN TEST HOLE. SIZE OBTAINED FROM SANITARY <br />MANHOLE. MATERIAL IS UNKNOWN DUE TO CONCRETE. PK SET OVER TOP OF 8" SANITARY. <br />NOTE: UNABLE TO OBTAIN SIZE DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST <br />HOLE. PLANS INDICATE A 20" SANITARY AT THIS LOCATION. TEST HOLE ALSO REVEALED A 3" <br />PLASTIC UNKNOWN, RUNNING EAST-WEST, 1.40' NORTH OF PK. COVER = 2.40. PK SET OVER TOP <br />OF SANITARY. <br />NOTE: TEST HOLE EXCAVATED ON ELECTRONIC SIGNAL AND GAS LOCATOR MARKS. TEST HOLE <br />REVEALED CONCRETE BELIEVED TO BE POURED OVER TOP OF 8" GAS. DID NOT EXCAVATE <br />FURTHER TO AVOID DAMAGE TO UTILITY. PK SET OVER TOP OF CONCRETE. <br />NOTE: TEST HOLE EXCAVATED ON ELECTRONIC SIGNAL AND WATER LOCATOR MARKS. TEST <br />HOLE REVEALED CONCRETE BELIEVED TO BE ON TOP OF 12" WATER. DID NOT EXCAVATE <br />FURTHER TO AVOID DAMAGE TO UTILITY. PK SET OVER TOP OF CONCRETE. <br />NOTE: TEST HOLE EXCAVATED AT REQUESTED LOCATION. TEST HOLE REVEALED 8" WRAPPED <br />STEEL GAS AT A 45° DOWNWARD ANGLE RUNNING WEST. PK SET OVER CROWN OF 8" GAS. <br />NOTE: UNABLE TO OBTAIN SIZE DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST <br />HOLE. PLANS INDICATE A 54" RCP STORM AT THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />UNABLE TO OBTAIN SIZE AND MATERIAL IN NEARBY MANHOLE FULL OF WATER AND DEBRIS. <br />NOTE: GAS REQUESTED AT THIS LOCATION. TEST HOLE REVEALED A 4" TELEPHONE CONDUIT. <br />PK SET OVER CROWN OF CONDUIT. SEE TEST HOLE 64A FOR GAS INFORMATION. <br />NOTE: TEST HOLE ALSO REVEALED A 4" PLASTIC U.F.P.L. (PER PLANS), RUNNING NORTHWEST- <br />SOUTHEAST, 0.80' NORTH OF PK. COVER = 2.50. PK SET OVER CROWN OF 8" GAS. <br />TEST HOLE NOTES <br />NOTE: TEST HOLE EXCAVATED ON WATER LOCATOR MARKS. UNABLE TO OBTAIN SIZE AND <br />MATERIAL DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST HOLE. PLANS INDICATE <br />A 12" WATER AT THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />NOTE: UNABLE TO OBTAIN SIZE DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST <br />HOLE. PLANS INDICATE A 54" RCP STORM AT THIS LOCATION. PK SET OVER TOP OF UTILITY. <br />UNABLE TO OBTAIN SIZE AND MATERIAL IN NEARBY MANHOLE FULL OF WATER AND DEBRIS. <br />NOTE: TEST HOLE EXCAVATED ON GAS LOCATOR MARKS. UNABLE TO OBTAIN SIZE AND <br />MATERIAL DUE TO EXCESSIVE GROUND WATER ENCOUNTERED IN TEST HOLE. PK SET OVER <br />TOP OF UTILITY. <br />Page 6 of 7
The URL can be used to link to this page
Your browser does not support the video tag.