My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2007-1103
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2007
>
Reso 2007-1103
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2015 2:31:40 PM
Creation date
10/29/2007 11:00:34 AM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2007-1103
Date (mm/dd/yyyy)
05/17/2007
Description
SR826 Project Bid Award & Agrmt w-Williams Paving (Bid# 07-03-02 $2,863,958.70)
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u <br />I <br />n <br />H111, <br />Mt <br />u <br />,� Ell, <br />580 -6 Method of Measurement. <br />The quantities to be paid will be the items shown in the Contract Documents, <br />completed and accepted. <br />580 -7 Basis of Payment. <br />Prices and payments will be full compensation for all work and materials specified in <br />this Section. <br />611 ACCEPTANCE OF SIGNAL INSTALLATIONS - SUBMITTAL REQUIREMENTS. <br />(REV 1- 14 -03) (FA 3- 22 -04) (1 -05) <br />SUBARTICLE 611 -2.3.1 (Page 680) is deleted and the following substituted: <br />611 -2.3.1 Submittal Requirements: Submit three sets of as -built plans for <br />review by the Engineer on reproductions of the original 11 by 17 inch sheets. Record all <br />as -built information using block lettering or typed text to ensure legibility. Signing and <br />pavement marking plan sheets may be used instead of signalization plan sheets, if a <br />substantial number of changes from the original signalization plans must be recorded. If, in <br />the opinion of the Engineer, the changes can not be clearly delineated on reproductions of <br />the original 11 by 17 inch sheets, clearly delineate all changes on 11 x 17 inch detail <br />sheets, enlarged 200% from the reproductions. Make any corrections resulting from the <br />Engineer's review, and resubmit three sets of the completed as -built plans as a condition <br />precedent to acceptance of the installation. <br />620 SIGNAL INSTALLATION GROUNDING. <br />(REV 7- 12 -01) (FA 1 -3 -02) (1 -04) <br />SUBARTICLE 620 -3.1 (Page 685). The first paragraph is deleted and the following <br />substituted: <br />620 -3.1 General: Meet all local electrical codes which exceed these Specifications. <br />Install all grounding conductors, which bond grounding electrode assemblies, 18 inches <br />[450 mm] below finished grade. Accomplish grounding for any element of a traffic signal <br />installation by installing either a grounding electrode assembly or a grounding electrode <br />array, unless otherwise specified in the Contract Documents. <br />Use solid No. 6 AWG copper insulated (green) conductor for electrical or <br />lightning protection ground from the system ground bus or barrier plate(s) to the grounding <br />electrodes and from grounding electrode to grounding electrode. Use either solid or <br />stranded No. 6 AWG copper insulated (green) conductor for all other applications. <br />`'s P <br />March 2007 01000 -145 03- 4122.D <br />
The URL can be used to link to this page
Your browser does not support the video tag.