Laserfiche WebLink
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />SECTION 03300 <br /> <br />CAST-IN-PLACE CONCRETE <br /> <br />PART 1 - GENERAL <br /> <br />1.01 WORK INCLUDED <br /> <br />A. Furnish labor, materials, equipment and incidentals required to place <br />cement and concrete masonry, reinforcing steel, forms, waterstops and <br />miscellaneous related items including sleeve, reglets, anchor bolts, inserts <br />and embedded items specified under other Section. <br /> <br />1.02 RELATED WORK <br /> <br />A. Testing is specified in Section 01410. <br /> <br />B. Concrete reinforcement is specified in Section 03200. <br /> <br />C. Precast Concrete Hollow Core Plank is specified in Section 03415. <br /> <br />D. Joints are specified in Section 03251. <br /> <br />E. Walkways are specified in Section 02510. <br /> <br />1.03 REFERENCE <br /> A. ASTM C-150 Portland Cement <br /> B. FS SS-C-1960/3 Portland Cement <br /> C. ASTM C-94 Ready-Mix Concrete <br /> D. ACI 318-89 Reinforced Concrete <br /> E. ASTM C-143 Concrete Mix <br /> F. ASTM C-231 Concrete Testing <br /> G. ASTM C-33 Concrete Aggregates <br /> H. ASTM C-87 Mortar Strength <br /> I. ASTM C-40 Concrete Aggregates <br /> <br />04/08 <br /> <br />03300-1 <br /> <br />06-5723 <br />