<br />12, NAME
<br />
<br />Francisco Garcia, P.E.
<br />
<br />E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
<br />(Complete one Section E for each kev person.)
<br />13, ROLE IN THIS CONTRACT
<br />Mechanical & Plumbing Design a TOTAL
<br />Engineer 7
<br />
<br />14, YEARS EXPERIENCE
<br />I b, WITH CURRENT FIRM
<br />< I Year
<br />
<br />15. FIRM NAME AND LOCATION (City and State)
<br />
<br />Venco Engineering Company / Fort Lauderdale, FL. 33309
<br />
<br />16, EDUCATION (DEGREE AND SPECIALlZA nON)
<br />HIGHER POLYTECHNIC INSTITUTE" Jose A. Echeverria" -
<br />Havana, Cuba
<br />B.S. in Mechanical Engineering, 1982
<br />(from a regionally accredited institution in the Unites States)
<br />
<br />17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
<br />State of Florida - Professional Engineer No. 64657
<br />
<br />18, OTHER PROFESSIONAL QUALIFICATIONS (Publications. Organizations, Training, Awards. etc)
<br />F.B.C. Workshop - Miami, FL. - 2007 / Florida Building Code (Mechanical) Workshop.
<br />F.B.C. Workshop - Miami, FL. - 2007 / Florida Building Code (Plumbing) Workshop.
<br />
<br />19. RELEVANT PROJECTS
<br />
<br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br /> Kandahar (Kspan Buildings): MRAP Support Facility, MRAP Fielding Facility, PROFESSIONAL SERVICES I CONSTRUCTION (II applicable)
<br /> RCP Maintenance Facility, Striker FRA Facility On-going
<br /> (3) BRIEF DESCRIPTION (Briel scope, size, cOSI, elc) AND SPECIFIC ROLE LxJ Check if project performed with current firm
<br />a.
<br /> Mechanical and Electrical design for four different I-story buildings (kspan type) of 11,840 S.F. each (open bay). Mechanical design
<br /> includes HV AC and exhaust fan equipment selection, supply and return duct design (extemal ducts as per client's request), energy
<br /> calculations and details. Electrical design includes Power and Lighting layout, fixtures selection, load calculations and panel schedule.
<br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br /> EUPOL - Kabul: Sports Building PROFESSIONAL SERVICES I CONSTRUCTION (II applicable)
<br /> Kabul, Afghanistan 2009
<br /> (3) BRIEF DESCRIPTION (Briel scope, size. cost, etc) AND SPECIFIC ROLE LxJ Check if project performed 'Nith current firm
<br />b.
<br /> Mechanical, Electrical and Plumbing design for a new 2-story sports building of 4, 740 S.F. The building is made up of2 multi-use
<br /> courts, weight lifting room, exercise room, lobby area and restrooms. Mechanical design includes HV AC and exhaust fan equipment
<br /> selection, energy calculations and details. Electrical design includes Power and Lighting layout, fixtures selection, load calculations and
<br /> panel schedule. Plumbing design includes water (cold and hot) and sewer piping layout, fixtures selection and details.
<br /> (1 )TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br /> Eupol - National Load Control Center PROFESSIONAL SERVICES I CONSTRUCTION (II applicable)
<br /> Kabul, Afghanistan 2009
<br /> (3) BRIEF DESCRIPTION (Briel scope, size. cost, etc) AND SPECIFIC ROLE lKJ Check if project performed with current firm
<br />c.
<br /> Electrical design for a I-story building (with a sub floor) of 8,565 S.F. The building is made up of 4 office areas, 2 vestibule rooms,
<br /> prayer room, storage room, open room, laboratory room, break room, development room, power supply room, battery room, cable
<br /> room, mechanical/electrical room, computers/communication room, operators' room, corridor and restrooms. Electrical design includes
<br /> Lighting layout.
<br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br /> Community Blood Centers of South Florida. (South Dade Facility PROFESSIONAL SERVICES I CONSTRUCTION (If applicable)
<br /> Expansion) 2009
<br /> (3) BRIEF DESCRIPTION (Briel scope, size, cost, etc) AND SPECIFIC ROLE U Check if project performed v./ith current firm
<br />d.
<br /> Mechanical and Plumbing design for an expansion of an existing I-story building in use as a Blood Center. Preparation of MEP plans
<br /> to be submitted along with architectural plans. Responsible for HV AC duct design, equipment selection, Mechanical details,
<br /> schedules and general notes, energy calculations, Plumbing details, schedules and general notes, water and sewer piping design, and
<br /> Computer Aided Design (CADD) drawings. (Size) 10,000 SF, t design
<br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br /> Islands at Doral PROFESSIONAL SERVICES I CONSTRUCTION (II applicable)
<br /> Miami, Florida. USA 2009
<br /> (3) BRIEF DESCRIPTION (Brie/scope, size, cosl, elc) AND SPECIFIC ROLE U Check it project performed with current firm
<br />e.
<br /> Mechanical and Plumbing design for a 2-story condominium building. Responsible for HV AC duct design, equipment
<br /> selection, Mechanical details, schedules and general notes, energy calculations, Plumbing details, schedules and general notes, water
<br /> and sewer piping design, and Computer Aided Design (CADD) drawings.
<br /> (Size) 4,000 SF.
<br />
<br />STANDARD FORM 330 (612004) PAGE 2
<br />
<br />Venco-Imtiaz Construction Company #2
<br />
|