My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Horsepower Electric #1
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(04-07-01) Roadway Lighting Improv. NE 159TH ST. & NE 174TH ST.
>
Responses
>
Horsepower Electric #1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2011 11:56:53 AM
Creation date
1/10/2011 10:15:02 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
NE 159TH ST. & NE 174TH ST. Roadwyay Lighting Improv.
Bid No. (xx-xx-xx)
04-07-01
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />through such special tests as directed by the Engineer, at the cost and <br />expense of the CONTRACTOR, or shall be replaced by the CONTRACTOR at <br />his own expense. <br /> <br />D. All electrical panels, enclosures, raceways, conduits, wireways, boxes, <br />cabinets, etc., shall be fabricated of metal. Nonmetallic substitutes are not <br />acceptable. This does not apply to buried work. <br /> <br />2.02 RACEWAYS AND FITTINGS <br /> <br />A. All conduit shall be Schedule 40 PVC. Burial depth as shown on the drawings. <br /> <br />2.03 CONDUCTORS <br /> <br />A. Conductors shall be copper. Power circuits shall have 600 volt PVC insulation <br />(Underwriters' approved Type THWN). Conductors shall be color coded in <br />accordance with the NEC. <br /> <br />2.04 PANELBOARDS <br /> <br />A. Rating <br /> <br />1. Panel board ratings shall be as shown on the Drawings. All panelboards <br />shall be rated for the intended voltage. <br /> <br />B. Standards <br /> <br />1. Panelboards shall be in accordance with the Underwriter Laboratories, <br />Inc. "Standard for Panelboards" and "Standard for Cabinets and Boxes" <br />and shall be so labeled where procedures exist. Panelboards shall also <br />comply with NEMA Standard for Panel boards and the NEC. <br /> <br />C. Construction (NEMA 4XSS) <br /> <br />1 . All interiors shall be completely factor assembled with circuit breakers, <br />wire connectors, etc. All wire connectors, except screw terminals, shall <br />be of the anti-turn solderless type and all shall be suitable for copper or <br />aluminum wire of the sizes indicated. <br /> <br />2. Interiors shall be so designed that circuit breakers can be replaced <br />without disturbing adjacent units and without removing the main bus <br />connectors and shall be so designed that circuits may be changed <br />without machining, drilling or tapping. <br /> <br />07/04 <br /> <br />160501-6 <br /> <br />03-4174 <br />
The URL can be used to link to this page
Your browser does not support the video tag.