Laserfiche WebLink
181 sr ACTIVE PARK <br />ADD. June 6, 2005 <br />• Contractor shall provide for a 24" well grate within bid price of Drainage Well <br />Structure. Shop drawing shall be submitted to Engineer for review. <br />• Plan note on PDD -1 sheet (17/28) shall be replaced as follows: <br />Replace note: <br />7. DRAINAGE WELL SHALL BE 24" OUTSIDE DIAMETER STEEL CASING <br />WITH 8 INCHES WALL THICKNESS ASTM A -53. <br />Replace with the following: <br />7. DRAINAGE WELL PIPE SHALL BE 24" CORRUGATED METAL PIPE (C.M.P.) <br />AS PER DETAIL. <br />All other documents, specifications, drawings, terms and conditions remain the same. <br />Bidders must acknowledge receipt of Addendum on Page 00300 -3. <br />ADDENDA 00900 -7 <br />