Laserfiche WebLink
<br />I <br /> <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />SECTION 02630 <br /> <br />STORM DRAINAGE PIPING <br /> <br />PART 1 - GENERAL <br /> <br />1.01 SCOPE OF WORK <br /> <br />A. Provide all labor, materials, necessary equipment and services to install the <br />storm drainage piping as indicated on the drawings, as specified herein or both. <br /> <br />1.02 RELATED WORK <br /> <br />A. Section 02100 - Site Preparation <br /> <br />B. Section 02200 - Earthwork <br /> <br />C. Section 02221 - Trenching, Bedding, and Backfill for Pipe <br /> <br />D. Section 02223 - Excavation Below Normal Grade and Gravel Refill <br /> <br />1.03 QUALITY ASSURANCE <br /> <br />A. Testing Agency: Independent testing laboratory <br /> <br />B. Requirements or Regulatory Agencies: Conform to requirements of all City, <br />County and State agencies. <br /> <br />C. Reference standards. <br /> <br />A. GENERAL: <br /> <br />All construction and materials shall conform to the Standards and Specifications of the <br />City of Sunny Isles Beach, Miami-Dade Water and Sewer Department (MDWASD), and <br />all other local and national codes where applicable. <br /> <br />All construction shall be performed in a safe manner, specifically, the rules and <br />regulations of the Occupational Safety and Health Administration (OSHA) and the <br />Manual of Uniform Traffic Control Devices (MUTCD) shall be strictly observed.B. <br />MATERIALS <br /> <br />This specification applies to high density polyethylene corrugated pipe with an integrally <br />formed smooth waterway. Nominal sizes for which this specification is acceptable are <br />100 -1500 mm (4 - 60 inch) diameters. Sizes 100 - 1500 mm (4 - 60 inch) shall be <br />either AASHTO Type'S' or Type 'D' as follows. Sizes 100 - 1500 mm (4 - 60 inch) <br />designated as MSHTO Type'S' (N-12) shall have a full circular cross-section, with an <br />outer corrugated pipe wall and an essentially smooth inner wall (waterway). <br />Corrugations for Type'S' sizes 100 - 1500 mm (4 - 60 inch) shall be annular (N-12). <br />Sizes 1050 - 1500 mm (42 thru 60 inch) designated as MSHTO Type 'D' (N-12HC) <br />shall consist of an essentially smooth waterway braced circumferentially with circular ribs <br />which are formed simultaneously with an essentially smooth outer wall. The 1050 - 1500 <br /> <br />06/07 <br /> <br />02630-1 <br /> <br />03-4197 <br />