Laserfiche WebLink
Addendum No. 2 - Bidder Questions and Responses <br />CONSTRUCTION OF WALL UNDER THE WILLIAM LEHMAN CAUSEWAY <br />CITY RFP NO. 13-10-02 <br /> <br /> <br /> <br />4 <br /> <br /> <br /> <br />12. Please clarify the As-Built requirement? <br /> <br />Response: At the completion of the project, the contractor shall submit at least three (3) <br />24X 36 signed and as-built drawings, <br /> As-builts must be signed and sealed by a Florida registered land surveyor <br /> The as-built shall be clearly captioned “AS-BUILT” in large letters on the top center <br />of the sheet <br /> Provide a location map at scale 1”=300’ and section-township-range should be <br />shown <br /> Preferred scale to be 1”=20’ horizontally <br /> The as-built drawings shall indicate Street nomenclature <br /> Identify all control lines (i.e. Bldg line, property line, right-of-way line etc) <br /> Stationing starts at 0+00 at permanent reference point (i.e CL, SL etc) and to run <br />continuously to end of wall <br /> Easements, if any, tied to permanent reference point <br /> Where the proposed improvements cross underground utilities, provide the <br />station, top of pipe/duct elevation, utility material and clearance from bottom of <br />wall <br /> If existing grade elevations are altered within project limits, the contractor shall <br />provide top of ground spot elevations every at every 100’ station <br /> If existing utility rim or structure elevations are altered, identify utility and provide <br />rim elevation and station <br /> <br />The contractor shall also provide electronic as-builts delivered in AutoCAD 2013 <br /> The drawing file is to be in model space utilizing the NAD83/Florida State Planes, <br />East Zone,(ft US) <br /> The drawing shall be layered in accordance with National CAD standards (NCS) <br /> Separate layer names should be used for all distinct objects surveyed. Do not <br />group dis-similar items together on the same layer. For example, do not place line <br />work and annotation on the same layer. <br /> All properties of the AutoCAD entities in the drawing are to be BYLAYER <br />(Absolutely No Exceptions Here). In other words do not change the properties of <br />individual entities. For example, do not place wall items on the electrical layer and <br />just change the color, linetype, or lineweight of the entity. Any user defined blocks <br />used in the drawing shall have all entities created on layer 0, and all other <br />properties shall be set to BYLAYER. <br /> <br />END OF SECTION