Laserfiche WebLink
EXAMPLE PROJECT KEY <br />NUMBER <br />21. TITLE AND LOCATION (City and State) 22.) <br />Stormwater & Pump Station Improvements Phase IVFESSIONAL SERVICES <br />r <br />Sweetwater, Florida 2011 <br />V. PROJECT OWNER <br />City of Sweetwater <br />23. PROJECT OWNER'S INFORMATION <br />POINT OF CONTACT <br />Eric Gomez, P.E. <br />24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (lnciudescope, six, andc"d <br />(if applicable) <br />2013 <br />X. POINT OF CONTACT TELEPHONE NUMBER <br />(305)553-5457 <br />Provided surveying, utility locating, FEMA grant applications, planning, design, cost estimates, preparation of <br />construction plans and contract documents, permitting, bidding, construction management and limited engineering <br />services during construction. The project was inspected and certified by the City Engineer's office. Due to <br />repetitive, historical flooding within the 138 acre residential area, Phase IV Stormwater Improvements for the City of <br />Sweetwater received substantial HMGP funding from FEMA. The projects consisted of 130 structures, 10,795 <br />linear feet of drainage pipe ranging in size from 15 -inch to 72 -inch, 1,506 linear feet of 30 -inch force main and two <br />(2) triplex stormwater pumping stations (28 HP). <br />Project Cost: $4,090,000 <br />25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT <br />M <br />(1) FIRM NAME <br />(2) FIRM LOCATION (City and State) <br />(3) ROLE <br />a. <br />Craig A. Smith & Associates, <br />Boca Raton, Florida <br />Prime Consultant <br />Inc. <br />(1) FIRM NAME <br />(2) FIRM LOCATION (Cityand State; <br />(3) ROLE <br />b. <br />(1) FIRM NAME <br />(2) FIRM LOCATION (City and State) <br />(3) ROLE <br />C. <br />M <br />