DRAIN SCHEDULE <br />PUMP SCHEDULE <br />PUMP IDENTIFICATION <br />& DESIGNATION <br />MANUFACTURER MODEL <br />NUMBER MODEL <br />ELECTRICAL REQUIREMENTS <br />REMARKS <br />POWER VOLTAGE [V]PHASE [Φ] <br />RP-1 BELL & GOSSETT 1/64 HP 115 1 LEAD FREE NSF-61, 304 STAINLESS STEEL, FLANGED, 125 PSI, UL <br />LISTED. <br />ECOCIRC <br />19-16 <br />PLUMBING FIXTURE ROUGHING SCHEDULE <br />WATER HAMMER ARRESTOR SCHEDULE <br />KITCHEN EQUIPMENT CONNECTION SCHEDULE <br />PLUMBING LEGEND, SYMBOLS AND ABBREVIATIONS PLUMBING FIXTURE SCHEDULE <br />PLUMBING GENERAL NOTESPLUMBING AS-BUILTS NOTE FIXTURE UNITS SCHEDULE <br />FIXTURE CONSUMPTION <br />AND FLOW RATES <br />PLUMBING FIXTURE DESIGNATION <br />PIPE DROPDROP <br />EQUIPMENT DESIGNATION <br />TEMPERATURE AND PRESSURE RELIEF VALVET & P <br />CONCRETE THRUST BLOCK <br />THERMOMETERT <br />TB <br />ROOF DRAIN <br />GARAGE DRAIN <br />TRENCH DRAINTD <br />RD <br />GD <br />WALL HYDRANTWH <br />FLOOR DRAINFD <br />TRAP PRIMER <br />HOSE BIBBHB <br />TP <br />WATER HAMMER ARRESTOR (SHOCK ABSORBER) <br />UNION <br />CAPPED PIPE <br />WATERTIGHT SLEEVE <br />SA <br />WALL CLEANOUT <br />FLUSH FLOOR CLEANOUT <br />GRADE CLEANOUTGCO <br />WCO <br />FCO <br />OPEN END DRAIN W/TRAP <br />BACKWATER VALVE <br />CLEANOUT PLUG <br />WASTE AND TRAPW&T <br />OED <br />CO <br />BWV <br />BALANCING VALVE <br />SHUT-OFF VALVE <br />CHECK VALVE <br />VALVE IN VERTICAL <br />CV <br />VIV <br />BV <br />DN <br />UP <br />PIPE DOWN <br />PIPE UP <br />FLOOR DRAIN WITH TRAPFD <br />GENERAL NOTE DESIGNATION <br />WC-1 <br />WTS <br />IW INDIRECT WASTE <br />S or W <br />S or W <br />RWL <br />RWL <br />V <br />V <br />RAIN WATER LEADER <br />RAIN WATER LEADER BELOW FLOOR <br />VENT BELOW FLOOR <br />VENT <br />SOIL OR WASTE <br />SOIL OR WASTE BELOW FLOOR <br />HWR <br />HW <br />HOT WATER RETURN <br />HOT WATER <br />OD OVERFLOW DRAIN <br />PLUMBING FIXTURE DESIGNATION <br />PIPE DROPDROP <br />EQUIPMENT DESIGNATION <br />TEMPERATURE AND PRESSURE RELIEF VALVET & P <br />CONCRETE THRUST BLOCK <br />THERMOMETERT <br />TB <br />ROOF DRAIN <br />GARAGE DRAIN <br />TRENCH DRAINTD <br />RD <br />GD <br />WALL HYDRANTWH <br />FLOOR DRAINFD <br />TRAP PRIMER <br />HOSE BIBBHB <br />TP <br />WATER HAMMER ARRESTOR (SHOCK ABSORBER) <br />UNION <br />CAPPED PIPE <br />WATERTIGHT SLEEVE <br />SA <br />WALL CLEANOUT <br />FLUSH FLOOR CLEANOUT <br />GRADE CLEANOUTGCO <br />WCO <br />FCO <br />OPEN END DRAIN W/TRAP <br />BACKWATER VALVE <br />CLEANOUT PLUG <br />WASTE AND TRAPW&T <br />OED <br />CO <br />BWV <br />BALANCING VALVE <br />SHUT-OFF VALVE <br />CHECK VALVE <br />VALVE IN VERTICAL <br />CV <br />VIV <br />BV <br />DN <br />UP <br />PIPE DOWN <br />PIPE UP <br />FLOOR DRAIN WITH TRAPFD <br />GENERAL NOTE DESIGNATION <br />WC-1 <br />WTS <br />IW INDIRECT WASTE <br />S or W <br />S or W <br />RWL <br />RWL <br />V <br />V <br />RAIN WATER LEADER <br />RAIN WATER LEADER BELOW FLOOR <br />VENT BELOW FLOOR <br />VENT <br />SOIL OR WASTE <br />SOIL OR WASTE BELOW FLOOR <br />HWR <br />HW <br />HOT WATER RETURN <br />HOT WATER <br />OD OVERFLOW DRAIN <br />CW COLD WATER <br />CW COLD WATER <br />CD CONDENSATE <br />1. THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING <br />OF ALL LABOR, MATERIALS AND EQUIPMENT, PERMITS, FEES, INSPECTIONS, TESTS AND <br />INSURANCE, REQUIRED FOR THE COMPLETION OF THE SYSTEMS AS SHOWN ON THE <br />DRAWINGS AND/OR LISTED BELOW. CONTRACTOR SHALL VISIT THE SITE PRIOR TO THE <br />BIDDING AND FAMILIARIZE HIMSELF WITH EXISTING EQUIPMENT, SYSTEMS AND BUILDING <br />STRUCTURE. <br />2. ALL EXISTING LOCATIONS ARE TAKEN FROM EXISTING DRAWINGS AND KNOWN FIELD <br />CONDITIONS. IT SHALL BE WITHIN THE SCOPE OF WORK TO VERIFY FIELD DIMENSIONS OF <br />EXISTING EQUIPMENT OR SYSTEMS PRIOR TO DEMOLITION OR FABRICATION OF NEW <br />WORK WHICH IS TO BE CONNECTED TO THE EXISTING. CONTRACTOR SHALL MAKE <br />OFFSETS AS REQUIRED IN NEW AND/OR EXISTING PIPING AND CONDUIT TO <br />ACCOMMODATE THE NEW WORK. <br />3. ALL WORK SHALL BE COORDINATED WITH EXISTING TRADES AND IN STRICT <br />COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. ALL DOWN TIME TO BE <br />COORDINATED WITH OWNER IN WRITING 72 HOURS PRIOR, AND SHALL BE BID AS <br />PREMIUM TIME. ALL DOWN TIME WORK SHALL BE PERFORMED AT NIGHT OR AS DIRECTED <br />BY THE OWNER. <br />4. ALL HOLES CREATED IN CEILING, PARTITIONS, ETC. AS A RESULT OF DEMOLITION SHALL <br />BE PATCHED BACK TO MAINTAIN THE EXISTING FIRE AND SMOKE INTEGRITY. <br />5. ALL EXISTING NON-REUSED MATERIALS AND EQUIPMENT TO BE TURNED OVER TO THE <br />OWNER. <br />6. THE CONTRACTOR SHALL GIVE THE OWNER A WRITTEN GUARANTEE THAT HE WILL MAKE <br />GOOD AT HIS OWN EXPENSE, ALL DEFECTS IN QUALITY OR WORKMANSHIP OF THE <br />MATERIAL AND INSTALLATIONS OF THIS WORK, FOR ONE YEAR AFTER THE DATE OF <br />ACCEPTANCE OF THE WORK BY THE ENGINEER. <br />7. CONTRACTOR SHALL CONNECT WATER AND WASTE TO EQUIPMENT FURNISHED BY <br />OTHERS AS INDICATED ON DRAWINGS. ALL FIXTURES TO BE PROTECTED AGAINST WATER <br />HAMMER BY SHOCK ARRESTERS. <br />8. ALL HOT AND COLD WATER PIPING SHALL BE COPPER TYPE-L, SFBC 46041(C) <br />COMPATIBLE UNLEADED SOLDER AND DIELECTRIC FITTINGS AS REQUIRED. SANITARY <br />WASTE AND VENT PIPING SHALL BE CAST IRON w/NO-HUB JOINTS. ALL HOT WATER, <br />CONDENSATE AND HORIZONTAL RWL PIPING SHALL HAVE 1" THICK FIBERGLASS <br />INSULATION WITH VAPOR BARRIER JACKET, FLAME SPREAD OF 25 OR LESS, SMOKE <br />DEVELOPED RATING OF LESS THAN 50, OWENS CORNING OR APPROVED EQUAL. <br />9. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA <br />PLUMBING CODE (2017 EDITION) AND - LOCAL ORDINANCE AND IN COMPLIANCE WITH THE <br />ENERGY CONSERVATION CODE. <br />10. THE PLUMBING CONTRACTOR WILL KEEP A SET OF MARKED UP DRAWING AS THE JOB <br />PROGRESSES. NO MAJOR CHANGE WILL BE MADE TO PLUMBING DESIGN ENGINEERING <br />UNLESS IT HAS BEEN COORDINATED, DRAWN AND SUBMITTED FOR APPROVAL TO THE <br />ARCHITECT/ENGINEER. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS/SUBMITTALS FOR <br />APPROVAL. <br />PLUMBING CONTRACTOR IS REQUIRED TO SUBMIT PLUMBING <br />AS BUILT PLANS UPON COMPLETION OF THE PROJECT. <br />COMPLETION IS DEFINED AS THE OWNER RECEIVING A "CO" <br />AND PLUMBING INSPECTOR HAS FINALIZED AND APPROVED <br />THE <br />INSTALLATION. <br />AS BUILTS SHALL BE SUBMITTED IN ELECTRONIC FASHION IN <br />EITHER AUTOCAD FORMAT OR SCANNED FILES IN PDF <br />FORMAT. <br />AS BUILTS SHALL BE LEGIBLE AND NEAT. AS BUILTS WILL BE <br />RETAINED BY ARCHITECT AND ENGINEER FOR RECORDS OF <br />CHANGES TO THE SYSTEM RECORD DRAWINGS. AS BUILTS <br />WILL BE SUBMITTED TO OWNER THROUGH ARCHITECT AND <br />ENGINEER. <br />11 <br />ZN-415S-P <br />REMARKSTYPEMODELMANUFACTURERTAG <br />FD-A ZURN - FLOOR <br />DRAIN <br />3" WITH TYPE 'S' STRAINER <br />LIGHT DUTY FLOOR DRAIN <br />FLOOR DRAIN,1/2" TRAP PRIMER CONNECTION, CAST IRON. POLISHED <br />NICKEL BRONZE TOP.PROVIDE WITH TRAP PRIMER. <br />ENAMEL LINER, LESS GRATE. CONTRACTOR SHALL COORDINATE EXACT <br />DRAIN LOCATION BASED ON EQUIPMENT PLACEMENT. PROVIDE WITH <br />TRAP PRIMER. <br />Z1902-P-1 12"X12"X10" DEEP CAST IRON ACID <br />RESISTANT INTERIOR FLOOR SINKZURN - FLOOR <br />SINKFS-1 <br />REFER TO PLANS FOR LOCATIONSZ1402 <br />4"X4" SQUARE TOP TUF-TOP NON <br />ADJUSTABLE FLOOR CLEANOUTZURN - FLOOR <br />CLEANOUTFCO <br />LOCATION <br />FINISHED AREAS <br />STERILIZER ROOM <br />REFER TO FLOOR PLANS <br />#8912 1 1/2" P-TRAPH-2165 <br />TYPE CW HW <br />BATHROOM GROUP (LAV, WC, BT/SH) 2.7 1.5 <br />ELECTRIC WATER COOLER 0.25 - <br />LAVATORY (PUBLIC)1.5 1.5 <br />WATER CLOSET (FLUSHOMETER VALVE) 10 - <br />NOTE: FIXTURE UNIT SCHEDULE IS SHOWN FOR CONVENIENCE ONLY. <br />TYPE MAXIMUM FLOW <br />RATE <br />URINAL 0.5GPF <br />SINK FAUCET 1.5GPM@60PSI <br />LAVATORY (PUBLIC)1.5GPM@60PSI <br />WATER CLOSET (FLUSHOMETER VALVE) 1.28GPF <br />FIXTURE UNITS 1-11 12-32 33-60 31-113 114-154 155-330 <br />PDI UNITS A B C D E F <br />PIPE SIZE 1/2"3/4"1"11/4" 1 <br />1/2"2" <br />NOTE: SIZING BASED ON 50 FT LENGTH AND WATER PRESSURE UP TO 65 PSIG. WHEN WATER PRESSURE IN LINE <br />EXCEEDS 65 PSI, SELECT NEXT LARGER SIZE PDI-PLUMBING & DRAINAGE INSTITUTE <br />**Note: Contractor shell coordinate all requirements with electrical contractor. <br />FIXTURE <br />SYMBOL TRAPSUPPLY <br />REMARKS <br />SIZETYPEMANUFACTURER MANUFACTURER TYPEMODEL FAUCET <br />C.WWASTE H.W. <br />FITTING FLOOR/WALL <br />MOUNTED <br />CARRIER <br />VENT <br />L-1 11/2"1/2" <br />WC-1 --4" 2" <br />UR-1 --2" 2" <br />EWC-1 NA NA --ELKAY <br />EZH20 BOTTLE <br />12"DRINKING FOUNTAIN NA NA Z-1225 <br />INSTALL PER <br />MANUFACTURERS <br />INSTRUCTIONS <br />-- <br />HB-1 <br />E27 - FULL FLOW <br />----NANANANANANANAWASHDOWN & SILL --3/4" <br />L-2 <br />11/4" <br />1/2"1/2" <br />112" <br />CHICAGO FAUCETS #387-E27CP <br />WC-2 --4"2"11/4" <br />FILLING STATION <br />#VRCGRNTL8WSK <br />ZURN <br />VACUUM BREAKER WITH <br />HOSE THREAD OUTLET <br />SK-1 ELKAY STAINLESS STEEL 20X22LRAD202255 McGuire LK99 STRAINER H170LK <br />8912 1 1/2" P TRAP <br />CHICAGO <br />0.5 GPM FLOW <br />201 AGN8AE35317 AB NA NA <br />UR URINAL 2" 2" 3/4" - <br />DF DRINKING FOUNTAIN 1-1/2" 1-1/2" 1/2" - <br />SK SINK 2" 2" 1/2" 1/2" <br />WC WATER CLOSET 4"2"1" - <br />TAG FIXTURE TYPE S/W V HWCW <br />LAV LAVATORY 2" 2" 1/2" 1/2" <br />K-30 HAND SINK 2" - 1/2" 1/2" 3/4" - - - - <br />N ATURAL GAS <br />BTUG180° F HW140° F HW <br />HOT WATER <br />TAG EQUIPMENT W V IW CW <br />110° F HW <br />REMARKS <br />K-1 MOP SINK 3"2"2" 1/2" 1/2" - - - - - <br />K-34 FIRE SUPRESSION SYSTEM --- 3/4" - - - - - - <br />K-36 COMBI OVEN --- - - - - 3/4" 170,000 - <br />K-38 WATER FILTRATION SYSTEM --- 3/4" - - - - - - <br />K-41 6 BURNER RANGE --- - - 3/4" 245,000 - <br />K-42 SALAMANDER BROILER --- - - - - 3/4" 40,000 - <br />K-43 WATER FILL FAUCET --- 1/2" - - - - - - <br />K-44 24" GRIDDLE --- - - - - 3/4" 60,000 - <br />K-45 24" BROILER --- - - - 3/4" 80,000 - <br />K-55 FLOOR TROUGH 4" - 3/4" - - - - - - <br />K-8 UNDERCOUNTER ICE MAKER --- 1/2" - - - - - - <br />K-12 ESPRESSO MAKER WATER FILTER --- 1/2" - - - - - - <br />K-51 UNDERCONTER DISH MACHINE --1" - 3/4" - - - - - <br />K-58 WATER FILTRATION SYSTEM --- 3/4" - - - - - - <br />K-15 DROP-IN HAND SINK 2"2"- 1/2" 1/2" - - - - - <br />K-10 WORK COUNTER WITH SINK 2"2"- 1/2" 1/2" - - - - - <br />K-23 COOK'S COUNTER WITH SINK 2"2"- 1/2" 1/2" - - - - - <br />K-50 UTENSIL SINK 2"-(3) 2" (2) 1/2" (2) 1/2" - - - - - <br />K-57 ICE BIN --1" - - - - - - - <br />WB-1 2"NANANANANANA7-5/8"x5-5/8"WASHER BOX 2"1/2"GUY GRAY #T200TPPVC <br />CENTER DRAIN POWDER <br />1/2"COATED STEEL WASHER <br />DRAIN AND SUPPLY BOX <br />NANANANANANA <br />NANANANANANA <br />NANANANANANA <br />NANANANANANA <br />NANANANANANA <br />NANANANA <br />NANANANA <br />NANANANA <br />NANANANA <br />NANANANA <br />3/4" <br />1/2"11/2" <br />11/2" 1 <br />1/2" <br />1/2"1/2"11/2" 1 <br />1/2" <br />REFER TO PLUMBING FIXTURE <br />SCHEDULE ON DRAWING A43-01 <br />FOR MANUFACTURER MAKE AND <br />MODEL NUMBERS <br />REFER TO PLUMBING FIXTURE <br />SCHEDULE ON DRAWING A43-01 <br />FOR MANUFACTURER MAKE AND <br />MODEL NUMBERS <br />REFER TO PLUMBING FIXTURE <br />SCHEDULE ON DRAWING A43-01 <br />FOR MANUFACTURER MAKE AND <br />MODEL NUMBERS <br />REFER TO PLUMBING FIXTURE <br />SCHEDULE ON DRAWING A43-01 <br />FOR MANUFACTURER MAKE AND <br />MODEL NUMBERS <br />REFER TO PLUMBING FIXTURE <br />SCHEDULE ON DRAWING A43-01 <br />FOR MANUFACTURER MAKE AND <br />MODEL NUMBERS <br />E-1 <br />IW <br />OD <br />E-1 <br />IW <br />OD <br />CW <br />CD <br />11. CODES AND STANDARDS <br />A. FURNISH AND INSTALL MECHANICAL SYSTEMS TO MEET ALL CURRENT REQUIREMENTS <br />OF NATIONAL, STATE <br />AND MUNICIPAL CODES, RULES REGULATIONS, LAWS, AND STANDARDS AS THEY ARE ADOPTED <br />BY THE <br />GOVERNING AGENCY AND AS THEY MAY APPLY. <br />1. FLORIDA BUILDING CODE 2017, BUILDING <br />2. FLORIDA BUILDING CODE 2017, PLUMBING <br />3. AIA GUIDELINES 2014 <br />4. NFPA-99 2015 <br />1423 <br />A <br />C <br />B <br />1423 <br />A <br />C <br />SHEET NUMBER <br />TITLE <br />Approved <br />Checked <br />Drawn <br />Job Number <br />ISSUE CHART <br />CONSULTANTS <br />KEYPLAN <br />PROJECT <br />B <br />FIRM CERTIFICATION C.A #6057 <br />JOHN MOULDER P.E: #33200 <br />CARLOS E. JIMENEZ P.E: #47923 <br />JOHN J. PETERS RCDD #193108R <br />BR+A CONSULTING ENGINEERS <br />2600 DOUGLAS ROAD, SUITE 1100 <br />CORAL GABLES, FL 33134 <br />t. 305.529.1515 <br />THORNTON TOMASETTI <br />101 NE THIRD AVENUE, SUITE 1170 <br />FORT LAUDERDALE, FL 3330` <br />f.954.903.9300 <br />f 954.903 9301 <br />ESI CONSULTING ENGINEERS, INC <br />1315 NW 98TH CT. <br />UNIT 15, DORAL, FL 33172 <br />t. 305.418.9177 t 305.418.9178 <br />HVAC <br />STRUCTURAL ENGINEERS <br />ELEC + PLUM + FPRO + TECH <br />INMAN FOODSERICE GROUP <br />1330 CORAL WAY <br />SUITE 310 <br />MIAMI, FL 33145 <br />FOOD SERVICE <br />PE <br />R <br />M <br />I <br />T <br /> <br />S <br />E <br />T <br /> <br />1 <br />2 <br />. <br />0 <br />6 <br />. <br />1 <br />8 <br />FIRM CERTIFICATION C.A #26243 <br />IGOR F. GONZALEZ P.E: #56098 <br />1 2 /1 1 /2 0 1 8 4 :3 2 :2 4 P M <br />C :\_R e v i t \P F P - G A T E W A Y - v 2 0 1 8 _j p e r e z @ b r p l u s a .c o m .r v t <br />P00-00 <br />LEGENDS, NOTES & <br />SHEET INDEX <br />Checker <br />Author <br />810495.000 <br />Approver <br />SIB -GATEWAY <br />PARK <br />Copyright © 2018 Perkins+Will <br />PROJECT ADDRESS: <br />151 Sunny Isles Blvd <br />Sunny Isles Beach, FL <br />33160 <br />2800 Ponce De Leon Blvd <br />Suite 1300 <br />Coral Gables, FL 33134 <br />t 305.569.1333 <br />f 305.569.1334 <br />www.perkinswill.com <br />PLUMBING SHEET INDEX <br />Sheet Number Sheet Name <br />P00-00 LEGENDS, NOTES & SHEET INDEX <br />P00-02 PLUMBING DETAILS <br />P10-01 LEVEL 01 - DRAINAGE <br />P10-02 LEVEL 01 - SUPPLY <br />P30-01 SANITARY RISER DIAGRAM <br />P30-02 DOMESTIC WATER RISER DIAGRAM <br />NO. ISSUE DATE <br />PERMIT SET 12.06.2018