My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications & Add.#1
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(04-05-01) Samson O. Pk Landsc. & Lighting
>
Specifications & Add.#1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2012 1:18:23 AM
Creation date
1/7/2011 10:22:52 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Samson O. Pk. Lands. & Lighting
Bid No. (xx-xx-xx)
04-05-01
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Ducts in use shall be sealed watertight at all pullboxes. Sealant <br />shall be foam type. <br />4. All joints shall be made so as to prevent the passage of concrete <br />inside the conduit to form obstructions or cause cable abrasions. <br />5. Pullbox covers in all areas shall finish 3- inches above crown of <br />adjacent ground elevation. <br />6. A 5/8 -inch by 10 -foot copperclad ground rod shall be driven in the <br />bottom of each pullbox. All bond wires and pullbox cover shall be <br />bonded to the ground rod. <br />PART 3 - EXECUTION <br />3.01 CONDUIT INSTALLATION <br />1 05/04 <br />A. Where conduits enter or leave all outlet boxes, cabinets safety switches, <br />tap boxes, motor controllers, etc., other than those having threaded <br />hubs, a standard lock nut shall be used on the outside of the box. <br />Busings 1 -inch and larger shall be of an approved insulated type. <br />B. During construction, all installed raceways shall be temporarily plugged or <br />otherwise protected from the entrance of moisture, dirt, trash, plaster, <br />moisture, etc., through neglect of the CONTRACTOR to so protect them, <br />shall be replaced by the CONTRACTOR without additional expense to the <br />Owner. No kinked, clogged or deformed raceways will be permitted on <br />the job. Raceways shall be cut to proper length so that ends will fit <br />accurately in the outlets. Where raceways cross building expansion <br />joints, a suitable raceway expansion fitting shall be used. <br />C. Size of raceway shall not be less than NEC requirements, but in no case <br />shall be less than indicated on the Drawings. Combining of circuits, other <br />than detailed, will not be permitted. The CONTRACTOR shall install <br />larger size raceways than detailed where there is excessive length of <br />unbroken run or excessive number of bends. <br />D. Bends in metallic raceways shall be made while "cold" and in no case shall <br />the raceways be heated. Raceways shall not be bent through more than <br />900. The radius of bends shall not be less than six (6) times the internal <br />diameter of the raceway. Not more than four (4) (equivalent 901) bends <br />will be permitted between outlets, the bends at the outlets being counted. <br />160501 -9 <br />03 -4465 <br />
The URL can be used to link to this page
Your browser does not support the video tag.